• Title/Summary/Keyword: ED Process

Search Result 240, Processing Time 0.036 seconds

Cystic Diseases of the Kidney in Children (소아의 낭포성 신질환)

  • Lee Ji-Suk;Rho Kwang-Sik;Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.144-150
    • /
    • 1997
  • Purpose : The kidney is one of the most common sites of cyst formation. Cystic diseases of the kidney are a diverse group of clinicopathologic entities and variable prognosis. They span a wide range of both age of presentation and severity of the renal disease. And many of them are systemic disorders, sharing similar process of cyst formation in other organs. Recently, development of imaging studies has been contributing widely to the diagnosis of the diseases. Treatment, however, is not established satisfactorily. We performed this study to evaluate the occurrence and treatment of cystic diseases of the kidney. Methods : We reviewed retrospectively the medical records of 44 patients with cystic diseases of the kidney in the Department of Pediatrics, during last 11 years. Results : In the 44 patients with cystic diseases of the kidney, 31 patients(71%) had multicystic dysplastic kidney and 11(35%) of them received nephrectomy due to differentiation from neoplasms or severe abdominal distension. Seven patients(16%) had polycystic kidney disease, and all of them were infantile type. Five patients(11%) were diagnosed as having a simple renal cysts. Progression to renal failure was noted in none of the cases. In 14(32%) out of total 44 patients, the diagnosis was made in neonatal or infantile pelted. Conclusion : The incidence of cystic diseases of the kidney appeared very low, but further investigation on their pathogenesis, classification, and indication of treatment is needed.

  • PDF

Hydrothermal Synthesis of Kaolinite and Change of Its Properties (캐올리나이트의 수열합성 및 특성변화)

  • Jang, Young-Nam;Ryu, Gyoung-Won;Chae, Soo-Chun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.241-248
    • /
    • 2009
  • Kaolinite was synthesized from amorphous $SiO_2$ and $Al(OH)_3{\cdot}xH_{2}O$ as starting materials by hydrothermal reaction conducted at $250^{\circ}C$ and $30\;kg/cm^2$. The acidity of the solution was adjusted at pH 2. The synthesized kaolinite was characterized by XRD, IR, NMR, FE-SEM, TEM and EDS to clarify the formational process according to the reaction time from 2 to 36 hours. X-ray diffraction patterns showed after 2 h of reaction time, the starting material amorphous $Al(OH)_3{\cdot}xH_{2}O$ transformed to boehmite (AlOOH) and after the reaction time 5 h, the peaks of boehmite were observed to be absent thereby indicating the crystal structure is partially destructed. Kaolinite formation was identified in the product obtained after 10 h of reaction and the peak intensity of kaolinite increased further with reaction time. The results of TGA and DTA revealed that the principal feature of kaolinite trace are well resolved. TGA results showed 13 wt% amount of weight loss and DTA analysis showed that exothermic peak of boehmite observed at $258^{\circ}C$ was decreased gradually and after 10 h of reaction time, it was disappeared. After 5 h of the reaction time, the exothermicpeak of transformation to spinel phase was observed and the peak intensiy increased with reaction time. The results of FT-IR suggested a highly ordered kaolinite was obtained after 36 hours of reaction. It was identified by the characteristic hydroxide group bands positioned at 3,696, 3670, 3653 and $3620\;cm^{-1}$. The development of the hydroxyl stretching between 3696 and $3620\;cm^{-1}$, depends on the degree of order and crystalline perfection. TEM results showed that after 15 h reaction time, curved platy kaolinite was observed as growing of (001) plane and after 36 h, the morphology of synthetic kaolinite exhibited platy crystal with partial polygonal outlines.

Study on the Manufacturing techniques & Conservation of Iron Pot from Cheonmachong Ancient Tomb (천마총 출토 철부(鐵釜)의 제작기법 및 보존처리)

  • Lee, Seung Ryul;Shin, Yong Bi;Jung, Won Seob
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.263-275
    • /
    • 2014
  • It's shown how to proceed the study on Manufacturing techniques & Conservation to the Iron Pot from Cheonmachong Ancient Tomb(the 155th Tomb in Hwangnam-dong). In order to investigate manufacturing techniques of the Iron Pot, some parts of the relic were gathered. After mounting, polishing and etching on the relic, analyzing the metal microstructure was conducted. Also it's conducted a SEM-EDS analysis on the nonmetallic inclusion. White iron structure was observed in the metallurgical structure inspection, SEM-EDS analysis. It seems to be dried slowly at room temperature after casting, doesn't look as particular heat treatment to improve brittleness. It is estimated that it's as the handle seam side were verified about 3cm inch wide, 1.5 thick in center of body, so 2 separate half-completed products was cast with width-type mould. The manufacturing techniques Using white cast iron structure, width-type mould are observable to the Iron Pot excavated from Sikrichong Ancient Tomb & Hwangnamdaechong grand Ancient Tomb around those were constructed the same time. It's able to recognize that it's almost identical manufacturing techniques at that time. Conservation is generically following those are survey of pretreatment, foreign material removal, stabilization, restoration and color matching in the order. cleaning & drying were added to the process as occasion demands. The strengthening treatment were difficult with artifact's volume, low concentration Paraloid NAD-10 solution was spread two or three times with a brush, surface hardening also came up with 15wt% Paraloid NAD-10 solution after the conservation was complete. There were connection & restoration for the restoration to the damage after modeling forms that it's similar to damaged parts by using the Fiber Reinforced Plastic resins(POLYCOAT FH-245, mold laminated type). Throughout this research, capitalizing on accumulations of measurements about the production technique of Iron Pot in the time of the fifth and 6th centuries is no less important than the Iron artifact's conservation for a better study in the future.

Bioaccumulation of Heavy Metals in Ruditapes philippinarum (바지락 (Ruditapes philippinarum) 의 중금속 축적에 관한 연구)

  • Lee, Yong-Seok;Jo, Yong-Hun;Byun, In-Sun;Kang, Se-Won;Cho, Eun-Mi;Han, Yeon-Soo;Choi, Sang-Haeng;Park, Hong-Seog;Kho, Weon-Gyu;Ahn, In-Young;Jeong, Kye-Heon
    • The Korean Journal of Malacology
    • /
    • v.22 no.2
    • /
    • pp.157-165
    • /
    • 2006
  • The present study was conducted to confirm that a bivalve Ruditapes philippinarum can be used as a biomarker for the monitoring of the heavy metal pollution in the silt of the marine environment. The clams were collected from the silt of Cheonsu-bay, Buheung-ri, and Tan-island of the West Sea, Korea. To observe the normal structures of the target organs (hepatopancreas and gill), they were dissected out for the immunohistochemical study and the electron microscopy with TEM, SEM, and SEM-EDS. The immunohistochemical study showed that the interdiverticular connective tissues of the hepatopancreas, and the outer epithelium of the gill lamellae was strongly reacted to anti-metallothionein (MT), indicating the presence of MT, a metal-binding protein, involved in metal detoxifying process. According to the examinations under the TEM, the epithelial cells of the hepatopancreas of the clams collected from polluted area (Tan-island) showed certain changes such as swollen rER, swollen nuclear envelope and inclusion bodies in the nulcei. In the SEM-EDS analysis, tissue of the hepatopancreas showed relatively higher concentration of S, Zn, and Cd. These elements are supposed to be concerning with the MT-reaction in the hepatopancreas. Considering that the coastal bivalve R. philippinarum showed immediate subcellular responses to heavy metal pollution in the overall experiments conducted, this species might act as one of efficient biomarkers for the heavy metal contamination in the marine environment.

  • PDF

On-Line Determination Steady State in Simulation Output (시뮬레이션 출력의 안정상태 온라인 결정에 관한 연구)

  • 이영해;정창식;경규형
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1996.05a
    • /
    • pp.1-3
    • /
    • 1996
  • 시뮬레이션 기법을 이용한 시스템의 분석에 있어서 실험의 자동화는 현재 많은 연구와 개발이 진행 중인 분야이다. 컴퓨터와 정보통신 시스템에 대한 시뮬레이션의 예를 들어 보면, 수많은 모델을 대한 시뮬레이션을 수행할 경우 자동화된 실험의 제어가 요구되고 있다. 시뮬레이션 수행회수, 수행길이, 데이터 수집방법 등과 관련하여 시뮬레이션 실험방법이 자동화가 되지 않으면, 시뮬레이션 실험에 필요한 시간과 인적 자원이 상당히 커지게 되며 출력데이터에 대한 분석에 있어서도 어려움이 따르게 된다. 시뮬레이션 실험방법을 자동화하면서 효율적인 시뮬레이션 출력분석을 위해서는 시뮬레이션을 수행하는 경우에 항상 발생하는 초기편의 (initial bias)를 제거하는 문제가 선결되어야 한다. 시뮬레이션 출력분석에 사용되는 데이터들이 초기편의를 반영하지 않는 안정상태에서 수집된 것이어야만 실제 시스템에 대한 올바른 해석이 가능하다. 실제로 시뮬레이션 출력분석과 관련하여 가장 중요하면서도 어려운 문제는 시뮬레이션의 출력데이터가 이루는 추계적 과정 (stochastic process)의 안정상태 평균과 이 평균에 대한 신뢰구간(confidence interval: c. i.)을 구하는 것이다. 한 신뢰구간에 포함되어 있는 정보는 의사결정자에게 얼마나 정확하게 평균을 추정할 구 있는지 알려 준다. 그러나, 신뢰구간을 구성하는 일은 하나의 시뮬레이션으로부터 얻어진 출력데이터가 일반적으로 비정체상태(nonstationary)이고 자동상관(autocorrelated)되어 있기 때문에, 전통적인 통계적인 기법을 직접적으로 이용할 수 없다. 이러한 문제를 해결하기 위해 시뮬레이션 출력데이터 분석기법이 사용된다.본 논문에서는 초기편의를 제거하기 위해서 필요한 출력데이터의 제거시점을 찾는 새로운 기법으로, 유클리드 거리(Euclidean distance: ED)를 이용한 방법과 현재 패턴 분류(pattern classification) 문제에 널리 사용 중인 역전파 신경망(backpropagation neural networks: BNN) 알고리듬을 이용하는 방법을 제시한다. 이 기법들은 대다수의 기존의 기법과는 달리 시험수행(pilot run)이 필요 없으며, 시뮬레이션의 단일수행(single run) 중에 제거시점을 결정할 수 있다. 제거시점과 관련된 기존 연구는 다음과 같다. 콘웨이방법은 현재의 데이터가 이후 데이터의 최대값이나 최소값이 아니면 이 데이터를 제거시점으로 결정하는데, 알고기듬 구조상 온라인으로 제거시점 결정이 불가능하다. 콘웨이방법이 알고리듬의 성격상 온라인이 불가능한 반면, 수정콘웨이방법 (Modified Conway Rule: MCR)은 현재의 데이터가 이전 데이터와 비교했을 때 최대값이나 최소값이 아닌 경우 현재의 데이터를 제거시점으로 결정하기 때문에 온라인이 가능하다. 평균교차방법(Crossings-of-the-Mean Rule: CMR)은 누적평균을 이용하면서 이 평균을 중심으로 관측치가 위에서 아래로, 또는 아래서 위로 교차하는 회수로 결정한다. 이 기법을 사용하려면 교차회수를 결정해야 하는데, 일반적으로 결정된 교차회수가 시스템에 상관없이 일반적으로 적용가능하지 않다는 문제점이 있다. 누적평균방법(Cumulative-Mean Rule: CMR2)은 여러 번의 시험수행을 통해서 얻어진 출력데이터에 대한 총누적평균(grand cumulative mean)을 그래프로 그린 다음, 안정상태인 점을 육안으로 결정한다. 이 방법은 여러 번의 시뮬레이션을 수행에서 얻어진 데이터들의 평균들에 대한 누적평균을 사용하기 매문에 온라인 제거시점 결정이 불가능하며, 작업자가 그래프를 보고 임의로 결정해야 하는 단점이 있다. Welch방법(Welch's Method: WM)은 브라운 브리지(Brownian bridge) 통계량()을 사용하는데, n이 무한에 가까워질 때, 이 브라운 브리지 분포(Brownian bridge distribution)에 수렴하는 성질을 이용한다. 시뮬레이션 출력데이터를 가지고 배치를 구성한 후 하나의 배치를 표본으로 사용한다. 이 기법은 알고리듬이 복잡하고, 값을 추정해야 하는 단점이 있다. Law-Kelton방법(Law-Kelton's Method: LKM)은 회귀 (regression)이론에 기초하는데, 시뮬레이션이 종료된 후 누적평균데이터에 대해서 회귀직선을 적합(fitting)시킨다. 회귀직선의 기울기가 0이라는 귀무가설이 채택되면 그 시점을 제거시점으로 결정한다. 일단 시뮬레이션이 종료된 다음, 데이터가 모아진 순서의 반대 순서로 데이터를 이용하기 때문에 온라인이 불가능하다. Welch절차(Welch's Procedure: WP)는 5회이상의 시뮬레이션수행을 통해 수집한 데이터의 이동평균을 이용해서 시각적으로 제거시점을 결정해야 하며, 반복제거방법을 사용해야 하기 때문에 온라인 제거시점의 결정이 불가능하다. 또한, 한번에 이동할 데이터의 크기(window size)를 결정해야 한다. 지금까지 알아 본 것처럼, 기존의 방법들은 시뮬레이션의 단일 수행 중의 온라인 제거시점 결정의 관점에서는 미약한 면이 있다. 또한, 현재의 시뮬레이션 상용소프트웨어는 작업자로 하여금 제거시점을 임의로 결정하도록 하기 때문에, 실험중인 시스템에 대해서 정확하고도 정량적으로 제거시점을 결정할 수 없게 되어 있다. 사용자가 임의로 제거시점을 결정하게 되면, 초기편의 문제를 효과적으로 해결하기 어려울 뿐만 아니라, 필요 이상으로 너무 많은 양을 제거하거나 초기편의를 해결하지 못할 만큼 너무 적은 양을 제거할 가능성이 커지게 된다. 또한, 기존의 방법들의 대부분은 제거시점을 찾기 위해서 시험수행이 필요하다. 즉, 안정상태 시점만을 찾기 위한 시뮬레이션 수행이 필요하며, 이렇게 사용된 시뮬레이션은 출력분석에 사용되지 않기 때문에 시간적인 손실이 크게 된다.

  • PDF

THE ROLE OF TYPE 2 DIABETES AS A PREDISPOSING RISK FACTOR ON THE PULPO-PERIAPICAL PATHOGENESIS: REVIEW ARTICLE (치수 치근단 병소의 전구 위험요인으로서의 제 2 형 당뇨의 역할에 관한 소고)

  • Kim, Jin-Hee;Bae, Kwang-Shik;Seo, Deog-Gyu;Hong, Sung-Tae;Lee, Yoon;Hong, Sam-Pyo;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.169-176
    • /
    • 2009
  • Diabetes Mellitus (DM) is a syndrome accompanied with the abnormal secretion or function of insulin, a hormone that plays a vital role in controlling the blood glucose level (BGL). Type land 2 DM are most common form and the prevalence of the latter is recently increasing, The aim of this article was to assess whet her Type 2 DM could act as a predisposing risk factor on the pulpo-periapical pathogenesis. Previous literature on the pathologic changes of blood vessels in DM was thoroughly reviewed. Furthermore, a histopathologic analysis of artificially-induced periapical specimens obtained from Type 2 diabetic and DM-resistant rats was compared. Histopathologic results demonstrate that the size of periapical bone destruction w as larger and the degree of pulpal inflammation was more severe in diabetic rats, indicating that Type 2 D M itself can be a predisposing risk factor that makes the host more susceptible to pulpal infection. The possible reasons may be that in diabetic state the lumen of pulpal blood vessels are thickened by atheromatous deposits, and microcirculation is hindered, The function of polymorphonuclear leukocyte is also impair ed and the migration of immune cells is blocked, leading to increased chance of pulpal infection. Also, lack of collateral circulation of pulpal blood vessels makes the pulp more susceptible to infection. These decrease the regeneration capacity of pulpal cells or tissues, delaying the healing process, Therefore, when restorative treatment is needed in Type 2 DM patients, dentists should minimize irritation to the pulpal tissue un der control of BGL.

Reliability of a Cobalt Silicide on Counter Electrodes for Dye Sensitized Solar Cells (코발트실리사이드를 이용한 염료감응형 태양전지 상대전극의 신뢰성 평가)

  • Kim, Kwangbae;Park, Taeyeul;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • Cobalt silicide was used as a counter electrode in order to confirm its reliability in dye-sensitized solar cell (DSSC) devices. 100 nm-Co/300 nm-Si/quartz was formed by an evaporator and cobalt silicide was formed by vacuum heat treatment at $700^{\circ}C$ for 60 min to form approximately 350 nm-CoSi. This process was followed by etching in $80^{\circ}C$-30% $H_2SO_4$ to remove the cobalt residue on the cobalt silicide surface. Also, for the comparison against Pt, we prepared a 100 nm-Pt/glass counter electrode. Cobalt silicide was used for the counter electrode in order to confirm its reliability in DSSC devices and maintained for 0, 168, 336, 504, 672, and 840 hours at $80^{\circ}C$. The photovoltaic properties of the DSSCs employing cobalt silicide were confirmed by using a simulator and potentiostat. Cyclic-voltammetry, field emission scanning electron microscopy, focused ion beam scanning electron microscopy, and energy dispersive spectrometry analyses were used to confirm the catalytic activity, microstructure, and composition, respectively. The energy conversion efficiency (ECE) as a function of time and ECE of the DSSC with Pt and CoSi counter electrodes were maintained for 504 hours. However, after 672 hours, the ECEs decreased to a half of their initial values. The results of the catalytic activity analysis showed that the catalytic activities of the Pt and CoSi counter electrodes decreased to 64% and 57% of their initial values, respectively(after 840 hours). The microstructure analysis showed that the CoSi layer improved the durability in the electrolyte, but because the stress concentrates on the contact surface between the lower quartz substrate and the CoSi layer, cracks are formed locally and flaking occurs. Thus, deterioration occurs due to the residual stress built up during the silicidation of the CoSi counter electrode, so it is necessary to take measures against these residual stresses, in order to ensure the reliability of the electrode.

Manufacturing Techniques of Bronze Seated Bodhisattva Statue of Goseongsa Temple in Gangjin (강진 고성사 청동보살좌상의 제작기술 연구)

  • LEE Seungchan;BAE Gowoon;CHUNG Kwangyong
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.146-159
    • /
    • 2024
  • In this study, a study on the production technology of the Buddha statue and the production of raw material origin was conducted through scientific analysis on the Bronze seated Bodhisattva Statue of Goseongsa Temple, a treasure. As a result of microstructure analysis through a metal microscope, it was confirmed that the microstructure of the Bronze seated Bodhisattva Statue of Goseongsa Temple was a process-type dendritic structure, and the casting structure of bronze was well represented, so it was manufactured through casting. Subsequently, as a result of analyzing the alloy composition ratio through SEM-EDS, it was identified as a ternary alloy with 81.26 wt% of copper (Cu) and 16.42 wt% of tin (Sn) and 1.72 wt% of lead (Pb). The results of the analysis of lead isotope ratios using a thermal ionization mass spectrometer (TIMS) were substituted into the distribution of lead isotope ratios on the Korean Peninsula, it was shown in corresponding to Jeolla-do and Chungcheong-do regions and North and South Gyeongsang Province. This suggests that the raw materials used in their production were likely sourced from the mines around Goseong Temple in Gangjin. Despite the fact that the statue is a medium and large Buddha with a total height of 51 centimeters, 1.72 wt% of lead (Pb) was found as a result of alloy composition ratio analysis, which showed a similar composition to the lead content ratio of small bronze and gilt-bronze Buddha statues. Therefore, we compared and analyzed the results of the analysis of the composition ratio of the alloys of bronze and gilt bronze statues, which has been scientifically analyzed with a compositional age similar to that of the Bronze seated Bodhisattva Statue of Goseongsa Temple. Comparison results, Various factors, such as the size of the Buddha statue as well as its stylistic characteristics and the age of composition, may exist in determining the alloy composition ratio of the bronze and gilt bronze Buddha statues, and it was confirmed that the alloy composition ratio or casting technology was properly adjusted when the Buddha statue was created. In other words, it is judged that a more comprehensive system of Buddha statue production technology should be investigated by conducting archaeological and art history studies on stylistic characteristics and age of composition, as well as scientific analysis results such as observation of internal structure, microstructure observation, and analysis of alloy composition ratio using radiation transmission irradiation.

The Effect of Nonspecific Endothelin-1 Receptor Blocker ($Bosentan^{(R)}$) on Paraquat Induced Pulmonary Fibrosis in Rat (Paraquat에 의한 백서의 폐섬유화증에서 비선택적 Endothelin-1 receptor blocker($Bosentan^{(R)}$)의 치료효과)

  • Jeong, Hye-Cheol;Jung, Ki-Hwan;Kim, Byung-Gyu;Lee, Seung-Heon;Kim, Min-Kyung;Kim, Chung-Yeul;Park, Sang-Myun;Lee, Sin-Hyung;Shin, Chol;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kim, Han-Gyum;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.182-195
    • /
    • 2001
  • Background : Idiopathic pulmonary fibrosis(IPF) is a devastating illness for which there is little effective treatment. The key cytokines currently implicated in the fibrotic process are the transforming growth factor-${\beta}_1$(TGF-${\beta}_1$), tumor necrosis factor-$\alpha$(TNF-$\alpha$), endothelin-1(ET-1) and interferon-$\gamma$(IFN-$\gamma$). The rat model for paraquat-induced pulmonary fibrosis was chosen to investigate the role of ET-1 in this disease. Both ET-1 and TGF-${\beta}_1$ expression in lung lesions were examined using immunohistochemical staining. After $Bosentan^{(R)}$ administration, an orally active ET-$l_A$ and ET-$1_B$ receptor antagonist, the degree of pulmonary fibrosis and ET-1 and TGF-${\beta}_1$ expression were analyzed. Method : Sprague-Dawley rats were divided into three groups, the control group, the fibrosis group, and the fibrosis-$Bosentan^{(R)}$-treated group. The animals were sacrificed periodically at 1, 3, 5, 7, 10, 14 days after administering saline or paraquat. The effects between groups were compared with the results of light microscopy and immunohistochemical staining for ET-1 and TGF-${\beta}_1$. The degree of fibrosis was evaluated by H&E and Masson's trichrome staining, which were graded by a computerized image analyzer. The degree of immunohistochemical staining was categorized by a semi-quantitative analysis method. Results : The lung collagen content had increased in the paraquat instillated animals by day 3, and continued to increase up to day 14. A daily treatment by gavage with $Bosentan^{(R)}$ (100mg/kg) did not prevent the increase in collagen deposition on the lung that was induced by paraquat instillation. There were increased immunohistochemical stains of ET-1 on the exudate, macrophages, vascular endothelial cells and pneumocytes in the paraquat instillated group. Furthermore, TGF-${\beta}_1$ expression was higher on the exudate, macrophages, some inflammatory cells, pneumocytes( type I, and II), vascular endothelium and the respiratory epithelial cells around the fibrotic area. After Bosentan treatment, there were no definite changes in ET-1 and TGF-${\beta}_1$ expression. Conclusion : Fibrosis of the Paraquat instillated group was more advanced when compared with the control group. In addition, there was increased ET-1 and TGF-${\beta}_1$ expression around the fibrotic area. ET-1 is associated with lung fibrosis but there was little effect of the ET-1 receptor blocker($Bosentan^{(R)}$) on antifibrosis.Background : Idiopathic pulmonary fibrosis(IPF) is a devastating illness for which there is little effective treatment. The key cytokines currently implicated in the fibrotic process are the transforming growth factor-${\beta}_1$(TGF-${\beta}_1$), tumor necrosis factor-$\alpha$(TNF-$\alpha$), endothelin-1(ET-1) and interferon-$\gamma$(IFN-$\gamma$). The rat model for paraquat-induced pulmonary fibrosis was chosen to investigate the role of ET-1 in this disease. Both ET-1 and TGF-${\beta}_1$ expression in lung lesions were examined using immunohistochemical staining. After $Bosentan^{(R)}$ administration, an orally active ET-$1_A$ and ET-$1_B$ receptor antagonist, the degree of pulmonary fibrosis and ET-1 and TGF-${\beta}_1$ expression were analyzed. Method : Sprague-Dawley rats were divided into three groups, the control group, the fibrosis group, and the fibrosis-$Bosentan^{(R)}$-treated group. The animals were sacrificed periodically at 1, 3, 5, 7, 10, 14 days after administering saline or paraquat. The effects between groups were compared with the results of light microscopy and immunohistochemical staining for ET-1 and TGF-${\beta}_1$. The degree of fibrosis was evaluated by H&E and Masson's trichrome staining, which were graded by a computerized image analyzer. The degree of immunohistochemical staining was categorized by a semi-quantitative analysis method. Results : The lung collagen content had increased in the paraquat instillated animals by day 3, and continued to increase up to day 14. A daily treatment by gavage with $Bosentan^{(R)}$ (100mg/kg) did not prevent the increase in collagen deposition on the lung that was induced by paraquat instillation. There were increased immunohistochemical stains of ET-1 on the exudate, macrophages, vascular endothelial cells and pneumocytes in the paraquat instillated group. Furthermore, TGF-${\beta}_1$ expression was higher on the exudate, macrophages, some inflammatory cells, pneumocytes( type I, and II), vascular endothelium and the respiratory epithelial cells around the fibrotic area. After Bosentan treatment, there were no definite changes in ET-1 and TGF-${\beta}_1$ expression. Conclusion : Fibrosis of the Paraquat instillated group was more advanced when compared with the control group. In addition, there was increased ET-1 and TGF-${\beta}_1$ expression around the fibrotic area. ET-1 is associated with lung fibrosis but there was little effect of the ET-1 receptor blocker($Bosentan^{(R)}$) on antifibrosis.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF