• Title/Summary/Keyword: ECO2 Simulation

Search Result 81, Processing Time 0.026 seconds

A Study on HILS System for Virtual Distribution System Using LabVIEW (LabVIEW를 이용한 가상 배전계통의 HILS 시스템 구축에 관한 연구)

  • Lee, Won-Seok;Hwang, Seon-Hwan;Kim, Tae-Seong
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.385-391
    • /
    • 2020
  • Overcurrent and abnormal voltages in the distribution system can cause not only burden of power plant but also damage to customers. As a result, researches related to the distribution automation have been widely conducted by utilizing a real time digital simulation to improve the reliability of power supply through rapid failure handing, reduction of power failure intervals and failure recovery. However, the distribution automation systems using the real time digital simulator are expensive and limited to verify actual hardwares. Therefore, in this paper, an external hardware devices was developed based on the distribution system analysis results of the digital simulator. And real-time simulation and functional verification are implemented by the real feeder remote terminal units used in distribution automation. The effectiveness of the proposed system is verified through several experiments.

Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments (다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석)

  • No, Min Hyung;Park, Jea Hong;Seo, Chang Won;Sung, Jung Gon;Yun, Duk Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.399-407
    • /
    • 2022
  • Energy absorption facilities installed on roads should follow the performance standards of the real-car crash test of 'Installation and Maintenance Guidelines for Roadside Safety Facilities'. However, due to different installation conditions, such as differing structure widths on roads, some energy absorption facilities do not provide adequate performance. In order to apply varied environments on roads, an energy absorption structure was designed in this study with 150 mm height and four layers of W-shape guardrail at 200 mm intervals, and the performance was verified using LS-DYNA computer simulation. Through a real-car crash test, the performance of the facility designed by LS-DYNA was tested and was found to meet the performance of the CC2 category for crash cushions. The conclusion of the comparison demonstrates that the simulation and the real-car crash tests are both significant.

Forged Product Characteristic and Cold Rolling Simulation for High-Nitrogen Stainless Steel (HNS) (TP304계 고질소 스테인레스강의 단조특성과 냉간압연 모사)

  • Lee, M.R.;Lee, J.W.;Kim, B.K.;Kim, Y.D.;Shin, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.310-313
    • /
    • 2009
  • Several high nitrogen stainless steel ingots(100kg) were fabricated with changing Ni and $[N]_2$ contents by Pressurized Vacuum Induction Melting(P_VIM). After free forging process, chemical compositions, microstructure and mechanical properties were estimated. Hardness was increased with the increase of $[N]_2$ content. Furthermore, microstructure including a lot of tempering twins was observed with optical microscope. Mechanical properties were estimated as function of solution treatment temperature and cooling method(air/water) under duration time of 1 hr on sample that were fabricated with Ni content under the atmospheric $[N]_2$ pressure. At solution treatment range of $1050{\sim}1100^{\circ}C$, hardness was decreased with the increase of solution temperature and there were little discrepancy of microstructure and hardness with cooling method. Computer simulation was carried out in order to inspect pass schedule in cold rolling process. When the condition of simulation was roll speed of 2.5mpm, rolling rate $15{\sim}17%$ per pass, it was ascertained that the formation such as deformation by sticking and lamellar sliver etc. was restricted from a simulation.

  • PDF

The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building (지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향)

  • Geon Ho Moon;Chang Yong Park
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.

Airship Research and Development in the Areas of Design, Structures, Dynamics and Energy Systems

  • Stockbridge, Casey;Ceruti, Alessandro;Marzocca, Pier
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.170-187
    • /
    • 2012
  • Recent years have seen an outpour of revived interest in the use of airships for a number of applications.Present day developments in materials, propulsion, solar panels, and energy storage systems and the need for a more eco-oriented approach to flight are increasing the curiosity in airships, as the series of new projects deployed in recent years show; moreover, the exploitation of the always mounting simulation capabilities in CAD/CAE, CFD and FEA provided by modern computers allow an accurate design useful to optimize and reduce the development time of these vehicles.The purpose of this contribution is to examine the different aspects of airship development with a review of current modeling techniques for airship dynamics and aerodynamics along withconceptual design and optimization techniques, structural design and manufacturingtechnologies and, energy system technologies. A brief history of airships is presented followed by an analysis of conventional and unconventional airships including current projects and conceptual designs.

Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System (저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구)

  • Cho, Jinkyun;Park, Beungyong;Lee, Yongjun;Chong, Wonho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

A Study of applying VAV and VWV System to reduce Energy Consumption of Office building (VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구)

  • Song, Ji-Yong;Hong, Won-Hwa;Kim, Ji-Yeon;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

Prediction of Environmental Change and Mitigation plan for large scale reclamation (대규모 매립에 대한 환경영향예측과 저감방안에 관한 연구)

  • Shin, Bum-Shick;Kim, Kyu-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.2
    • /
    • pp.95-100
    • /
    • 2010
  • In this study we predicted some of the negative effects on the ocean ecosystem and water quality, caused by a coastal reclamation project in semi-closed bay that makes it extremely difficult to be purified by natural process. In order to predict change of water quality triggered by coastal reclamation, the 3D hydrodynamic model and material cycle model are used. And we suggested new ecological park, an artificial beach and eco-friendly revetments on the reclamation area to mitigate the environmental impacts affecting this area using the numerical simulation results and observation data.

Numerical Simulation for Urban Climate Assessment and Hazard (도시기후 평가와 방재를 위한 도시기상 수치모의)

  • O, Seong-Nam
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.40-47
    • /
    • 2002
  • Since it is important to understand the bio-climatic change in Seoul for ecological city planning in the future, this paper gives an overview on bio-climate analysis of urban environments at Seoul. We analyzed its characteristics in recent years using the observations of 24 of Automatic Weather Station (AWS) by Korea Meteorological Administration (KMA). In urbanization, Seoul metropolitan area is densely populated and is concentrated with high buildings. This urban activity changes land covering, which modifies the local circulation of radiation, heat and moisture, precipitation and creating a specific climate. Urban climate is evidently manifested in the phenomena of the increase of the air temperature, called urban heat Island and in addition urban sqall line of heavy rain. Since a city has its different land cover and street structure, these form their own climate character such as climate comfort zone. The thermal fold in urban area such as the heat island is produced by the change of land use and the air pollution that provide the bio-climate change of urban eco-system. The urban wind flow is the most important climate element on dispersion of air pollution, thermal effects and heavy shower. Numerical modeling indicates that the bio-climatic transition of wind wake in urban area and the dispersion of the air pollution by the simulations of the wind variation depend on the urban land cover change. The winds are separately simulated on small and micro-scale at Seoul with two kinds of kinetic model, Witrak and MUKLIMO.

  • PDF

Comparison and analysis of typical metrological data by in korea (대한민국의 지역별 표준기상데이터 비교분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan;Kang, Hyun-Gu;Shin, In-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.361-366
    • /
    • 2009
  • Amid the crisis of global climate change, interest in low carbon and energy-saving building has been increasingly growing. Korea is likely to be designated as one of the countries subject to CO2 reduction under the 'Post-2012 Climate System' The efforts to minimize the building energy has been made and in line with the increasing need of low carbon and eco-friendly building, a demand for building evaluation programs has been on the rise. However, the metro logical data which is necessary for such program has not been effectively provided and moreover, the source, calculation method and period remain uncertain. This study was intended to evaluate the regional typical metro logical data (ISO TRY) provided by Korean Solar Energy Society and compile the month of test reference years (TRY), and analyze the regional weather using dry-bulb temperature, wet-bulb temperature and solar irradiance which are regarded the representative metro logical data.

  • PDF