• 제목/요약/키워드: ECG parameters

Search Result 138, Processing Time 0.022 seconds

Design of neural network based ALE for QRS enhancement (QRS 파의 증대를 위한 신경망 ALE 설계)

  • 원상철;박종철;최한고
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.217-220
    • /
    • 2000
  • This paper describes the application of a neural network based adaptive line enhancer (ALE) for enhancement of the weak QRS complex corrupted with background noise. Modified fully-connected recurrent neural network is used as a nonlinear adaptive filter in the ALE. The connecting weights between network nodes as well as the parameters of the node activation function are updated at each iteration using the gradient descent algorithm. The real ECG signal buried with moderate and severe background noise is applied to the ALE. Simulation results show that the neural network based ALE performs well the enhancement of the QRS complex from noisy ECG signals.

  • PDF

Effects of Cyclobuxine D on the Electrocardiogram (ECG) and Heart Rate in Anesthetized Rats and Isolated Frog Heart (Cyclobuxine D의 흰쥐에 있어서 ECG와 심박동수에 패한 작용과 적출 개구리 심장에 대한 작용)

  • Lee, Jong-Hwoa;Park, Young-Hyun;Cho, Byung-Heon;Kim, Yu-Jae;Kim, Jong-Bae;Kim, Chun-Sook;Cha, Young-Dong;Kim, Young-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.22 no.2
    • /
    • pp.105-114
    • /
    • 1986
  • This study was undertaken to search for a new antiarrhythmic agent in natural plants. Extracts of Buxus microphylla var. koreana Nakai have been used as folk remedies of several diseases, including malaria and venereal disease, but any study on the pharmacological actions of this plant has not yet been carried out and its active ingredients have not been identified. In our laboratory, we isolated buxuletin (nonalkaloid) and cyclobuxine D (steroidal alkaloid) from Buxus microphylla var. koreana Nakai and reported their pharmacological actions: diuretic effects of buxuletin in rabbits and hypotensive effect of cyclobuxine D in rats. In the present study, we investigated the effect of cyclobuxine D on isolated frog heart and heart rate in urethane anesthetized rats. In order to clarify the mechanism of bradycardic effect of cyclobuxine D, we examined the changes of the ECG parameters (PR, QRS and R ${\alpha}$ T interval) produced by intravenous injection of cyclobuxine D in anesthetized rats. Cyclobuxine D depressed the contractile force in isolated frog heart and exerted a dose-dependent bradycardic effect in anesthetized rats. Intracerebroventricular injection of cyclobuxine D caused a fall in blood pressure and an increase in heart rate, but those effects were not significant. Cyclobuxine D prolonged the PR interval and RaT interval (${\alpha}$ Tindicates the apex of T), but was without significant effects on the duration of the QRS complex and PRc in urethane anesthetized rats.

  • PDF

The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot (활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화)

  • Seo, Hye-Eun;Lim, Hae-Ri;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.462-468
    • /
    • 2007
  • Purpose : The purpose of this study was to analyze the changes of the late potential of Signal- averaged electrocardiography (SAECG) and Electrocardiography (ECG) parameters during follow up of those who had taken surgical repair of Tetralogy of Fallot (TOF). Methods : Nine patients who had taken surgical repair of TOF since 1985 checked SAECG and standard 12 leads ECG twice in 1999 and 2005 in Kyungpook national university hospital. We evaluated changes of QRS duration, QT interval and JT interval, QRS dispersion, QT dispersion and JT dispersion of standard 12 leads ECG and Filtered QRS (f-QRS), High frequency low amplitude potential (HFLA), Root mean square in terminal 40 ms (RMS) and Mean voltage in terminal 40 ms (MV) of SAECG between in 1999 and 2005. Results : There were significant decrease of JT dispersion ($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P< 0.05) and significant increase of HFLA ($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). But there were no significant changes in other parameters. Conclusion : In repaired TOF patients, we evaluated ECG and SAECG to detect possible late complications such as tricuspid regurgitation, right ventricular enlargement, ventricualar arrythmia and sudden death. And there were significant changes of ECG and SAECG in some parameters (JT dispersion, HFLA). But to see the relationships between the changes of these parameters and the long term prognosis, we need to check more patients and longer follow-up.

BIOFIT - Smart, Portable, Wearable and Wireless Digital Exercise Trainer Device with Biofeedback Capability

  • Diwakar Praveen Kumar;Oh Young-Keun;Chung Gyo-Bum;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.36-45
    • /
    • 2007
  • Today Human Personal Trainers are becoming very famous in this health conscious world. They teach user to achieve fitness goals in managed way. Due to their high fee and tight schedule they are unavailable to mass number of people. Another solution to this problem is to develop digital personal trainer portable instrument that may replace human personal trainers. We developed a portable digital exercise trainer device - BIOFIT that manages, monitors and records the user's physical status and workout during exercise session. It guides the user to exercise efficiently for specific fitness goal. It keeps the full exercise program i.e. exercises start date and time, duration, mode, control parameter, intensity in its memory which helps the user in managing his exercise. Exercise program can be downloaded from the internet. During exercise it continuously monitors the user's physiological parameters: heart rate, number of steps walked, and energy consumed. If these parameters do not range within prescribed target zone, the BIOFIT will alarm the user as a feedback to control exercise. The BIOFIT displays these parameters on graphic LCD. During exercise it continuously records the heart rate and number of steps walked every 10 seconds along with exercise date and time. This stored information can be used as treatment for the user by an exercise expert. Real-time ECG monitoring can be viewed wirelessly (RF Communication) on a remote PC.

Wireless Power Transmission Technology for Implantable Telemetry Device based on Multiple Transmit Coils (다중코일방식에 기초한 원격 생체 정보 측정을 위한 무선전력전송 기술)

  • Ryu, Young-Kee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.203-211
    • /
    • 2015
  • The implanted telemetry system provides the monitoring of species while they move within their cages. Species monitored include mice, rats, rabbits, dogs, pigs, primates, sheep, horses, cattle, and others. A miniature transmitter implanted in each animal measures one or more parameters. Parameters measured include arterial pressure, intra-pleural pressure, left ventricular pressure, intra-ocular pressure, bladder pressure, ECG, EMG, EEG, EOG, temperature, activity, and other parameters and transmits the data via radio frequency signals to a nearby receiver. Every conventional dedicated transmitter contains one or more sensors, cpu and battery. Due to the expected life of battery, the measuring time is limited. To overcome these problems, electromagnetic inductive coupling based wireless power transmission technology using multiple transmit coils were proposed. Each coil having different active area are driven by the coil driver. In this research, parallel resonance based coil driver was proposed. In addition, the device to detect where the receiver is positioned was proposed. From the experiments we show how to determine the driving condition of coil driver.

Correlation between Pulse-respiration Ratio and Heart Rate Variability (맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究))

  • Yang, Dong-Hoon;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

Polysomnography and Multiple Sleep Latency Test (수면검사다원검사와 수면잠복기반복검사)

  • Cho, Jae Wook
    • Annals of Clinical Neurophysiology
    • /
    • v.14 no.1
    • /
    • pp.7-11
    • /
    • 2012
  • Polysomnography is used to diagnose many types of sleep disorders including sleep apnea, periodic limb movement disorder, REM sleep behavior disorder, parasomnias, and narcolepsy. It is a comprehensive recording of the biophysiological changes that occur during sleep. The polysomnography monitors many body functions parameters including EEG, EOG, EMG, ECG, respiratory airflow, respiratory effort, and pulse oximetry during sleep. Multiple Sleep Latency Test (MSLT) is performed for diagnosing narcolepsy and excessive daytime sleepiness. It is usually to be done after an overnight polysomnography. The test consists of four or five 20-minute nap opportunities that are scheduled two hours apart.

The Study on the Feature Point Recognition and Classification of Radial Pulse (맥파의 특징점 인식과 파형의 분류에 관한 연구)

  • 길세기;김낙환;이상민;박승환;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.555-558
    • /
    • 1999
  • In this paper, Ire present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also we specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm. then we classify the shape of radial pulse by existence and position of feature points.

  • PDF

A Study of the Atrial Arrhythmia Diagnosis Algorithm (심방성 부정맥 진단 알고리즘에 관한 연구)

  • 황선철
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 1989
  • This papaer presents a new algorithm for the P-wave detection in the ECG signal. Digital differentiation method (7-point derivative) is used for detecting P-waves exactly. This algorithm can detect various parameters of PR, PP, RR interval, which are important to diagnosis AV blocks and WPW syndrome. Especially, this algorithm can detect P-waves very efficiently not only in well-preprocessed waves but in pccr waves with noise and artifact. And it enables to develope more reliable automatic diagnosis algorithm.

  • PDF

청각 감성의 생리적 신호변화에 대한 연구

  • 황민철;김지은;김철중
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.259-263
    • /
    • 1996
  • Psychological action is physiological response of outernal stimulus. Physiological response is accompanied b physiological signals which are EEG, EMG, GSR, ECG, BP, and tec. Physiological signals are recently studied for determination of human phychological state. Psychological activity causes electric potential of brain. Physiological signal is considered as measurement of human psychological state. Aditory sensibility which is one of the sense of human may determine differences between positive and negative feeling. EEG and GSR variation with auditory quality of stimulus can be define human negative and positive mental state. This study is to characterize parameters which can determine negative and positive psycholigical state of human.

  • PDF