• Title/Summary/Keyword: ECG monitoring

Search Result 257, Processing Time 0.024 seconds

Real-time Intelligent Health and Attention Monitoring System for Car Driver by Measurement of Vital Signal (생체신호 측정에 의한 실시간 지능형 운전자 건강 및 주의 모니터링 시스템)

  • Shin, Heung-Sub;Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.545-548
    • /
    • 2009
  • Recently, researches related to automative mechanism have been widely studied to increase the driver's safety by continuously monitoring the driver's health condition to prevent driver's drowsiness. This paper describes the design of wearable chest belt for ECG and reflectance pulse oximetry for $SpO_2$ sensors based on wireless sensor network to monitor the driver's healthcare status. ECG, $SpO_2$ and heart rate signals can be transmitted via wireless sensor node to base station connected to the server. Intelligent monitoring system is designed at the server to analyze the $SpO_2$ and ECG signals. HRV(Heart Rate Variability) signals can be obtained by processing the ECG and PPG signals. HRV signals are further analyzed based on time and frequency domain to determine the driver's drowsiness status.

  • PDF

Design and Implementation of Real-Time ECG Monitoring System Using Cortex-M3 Microprocessor (Cortex-M3 Microprocessor를 이용한 실시간 ECG Monitoring System 설계 및 구현)

  • Kim, Tae Wan;Kwon, Chun Ki;Lee, On Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.893-895
    • /
    • 2016
  • 세계적으로 헬스케어 산업의 발전 가능성은 눈에 띄게 증가하고 있다. 그 중에서도 환자 혹은 각종 디바이스 사용자의 생체신호를 다루는 기술은 다양한 중요정보를 얻을 수 있다. 본 논문에서는 심전도의 미세한 생체 전위를 측정하기 위해 각종 필터와 증폭기를 이용하여 회로를 설계하고 이를 Cortex-M3 Microprocessor와 MATLAB 프로그램을 이용하여 필터링과 데이터통신을 통해 최종적으로 실시간으로 모니터링 하였다. 일반적으로 임상이나 진단에 이용되는 ECG 신호는 각종 심장질환의 지표로 사용되지만 전문적인 지식을 갖추지 않은 일반 사용자가 사용하기에는 어려운 점이 없지 않아 있다. 따라서 이 연구는 아날로그 신호를 디지털 신호로 변환하여 생체신호를 다루는 다양한 분야에서 용이할 수 있다.

A Lightweight HL7 Message Strategy for Real-Time ECG Monitoring (실시간 심전도 모니터링을 위한 HL7 메시지 간소화 전략)

  • Lee, Kuyeon;Kang, Kyungtae;Lee, Jaemyoun;Park, Juyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • Recent developments in IT have made real-time ECG monitoring possible, and this represents a promising application for the emerging HL7 standard for the exchange of clinical information. However, applying the HL7 standard directly to real-time ECG monitoring causes problems, because the partial duplication of data within an HL7 message increases the amount of data to be transmitted, and the time taken to process it. We reduce these overheads by Feature Scaling, by standardizing the range of independent variables or features of data, while nevertheless generating HL7-compliant messages. We also use a De-Duplication algorithm to eliminate the partial repetition of the OBX field in an HL7 ORU message. Our strategy shortens the time required to create messages by 51%, and reduces the size of messages by 1/8, compared to naive HL7 coding.

Design and Implementation of Biosignal Monitoring for Enhancement of Soldier Survivability (개인병사의 생존성 증대를 위한 생체신호 모니터링 기법의 설계 및 구현)

  • Lee, Seung-Youl;Park, Sang-Hoon;Lee, Choon-Woo;Kim, Hyun-Jun;Chae, Jae-Wook
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.841-846
    • /
    • 2013
  • Recently, personal health monitoring system using intelligent biosensors and equipments has been realized. This system can be adopted for soldier's biosignal monitoring system. In this paper, we propose a soldier biosignal monitoring system using personal biosensors, such as the ECG sensors and accelerometer.

A study on the measure instrument of heart sound and electrocardiogram by portable (휴대형 심음 및 심전도 측정장치에 관한 연구)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.237-240
    • /
    • 2009
  • We suggested the portable measurement system that estimate heart-condition for heart disease patients and healthy. We used informations of ECG and PCG in this system. The informations of ECG and PCG obtained by using electrodes and microphone, respectively.

  • PDF

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System (CDMA망 기반 3채널 심전도 모니터링 시스템의 평가)

  • Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.

Acquisition of Multi-channel Biomedical Signals Based on Internet of Things (사물인터넷 기반의 다중채널 생체신호 측정)

  • Kim, Jeong-Hwan;Jeung, Gyeo-Wun;Lee, Jun-Woo;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1252-1256
    • /
    • 2016
  • Internet of Things(IoT)-devices are now expanding inter-connecting networking technologies to invent healthcare monitoring system especially for assessing physiological conditions of the chronically-ill patients those with cardiovascular diseases. Hence, IoT system is expected to be utilized for home healthcare by dedicating the original usage of IoT devices to collect the biomedical data such as electrocardiogram(ECG) and photoplethysmography(PPG) signal. The aim of this work is to implement health monitoring system by integrating IoT devices with Raspberry-pi components to measure and analyze ECG and the multi-channel PPG signals. The acquired data and fiducial features from our system can be transmitted to mobile devices via wireless networking technology to support the concept of tele-monitoring services based on IoT devices.

A Method for Estimation and Elimination of EGG Artifacts from Scalp EEG Using the Least Squares Acceleration Based Adaptive Digital Filter (최소 제곱 가속 기반의 적응 디지털 필터를 이용한 두피 뇌전도에서의 심전도 잡음 추정 및 제거)

  • Cho, Sung-Pil;Song, Mi-Hye;Park, Ho-Dong;Lee, Kyoung-Joung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1331-1338
    • /
    • 2007
  • A new method for detecting and eliminating the Electrocardiogram(ECG) artifact from the scalp Electroencephalogram(EEG) is proposed. Based on the single channel EEG, the proposed method consists of 4 procedures: emphasizing the R-wave of ECG artifact from EEG using the least squares acceleration(LSA) filter, detecting the R-wave from the LSA filtered EEG using the phase space method and R-R interval, generating the delayed impulse synchronized to the R-wave and elimination of the ECG artifacts based on the adaptive digital filter using the impulse and raw EEG. The performance of the proposed method was evaluated in the two separating parts of R-wave detection and, ECG estimation and elimination from EEG. In the R-wave detection, the proposed method showed the mean error rate of 6.285(%). In the ECG estimation and elimination using simulated and/or real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, in which independent component analysis and ensemble average method are used. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifact from single channel EEG and simple for ambulatory/portable EEG monitoring system.