Abstract

Recent developments in IT have made real-time ECG monitoring possible, and this represents a promising application for the emerging HL7 standard for the exchange of clinical information. However, applying the HL7 standard directly to real-time ECG monitoring causes problems, because the partial duplication of data within an HL7 message increases the amount of data to be transmitted, and the time taken to process it. We reduce these overheads by Feature Scaling, by standardizing the range of independent variables or features of data, while nevertheless generating HL7-compliant messages. We also use a De-Duplication algorithm to eliminate the partial repetition of the OBX field in an HL7 ORU message. Our strategy shortens the time required to create messages by 51%, and reduces the size of messages by 1/8, compared to naive HL7 coding.

최근 IT 기술이 발전함에 따라 실시간 심전도 모니터링이 가능해 졌으며, 이는 의료정보교환을 위한 HL7 표준의 전도 유망한 응용 중 하나로 인식되고 있다. 하지만 HL7 메시지 내 데이터 중복으로 인한 메시지의 크기 및 생성시간의 증가로 인해 HL7 표준을 실시간 심전도 모니터링에 바로 적용하기에는 무리가 있다. 이에 본 논문에서는 실시간 심전도 모니터링에 적합한 HL7 메시지의 간소화 전략을 제안한다. 다양한 형식의 심전도 데이터를 Feature Scaling을 거쳐 정형화된 포맷으로 조정하고 HL7 규약에 순응하는 메시지를 생성한다. 또한 HL7 ORU 메시지 내의 중복되는 OBX 필드를 제거하기 위해 De-Duplication 알고리즘을 수행한다. 이를 통해 기존의 HL7 표준 적용 대비 메시지의 생성시간은 최대 51%, 크기는 최대 1/8로 줄일 수 있음을 실험적으로 확인하였다.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. S. Chun, J. Nah, and J. Park, "Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M," Journal of Korea Information and Communication Society, Vol. 36, No. 3, pp. 275-286, Mar. 2011. (in Korean) https://doi.org/10.7840/KICS.2011.36B.3.275
  2. I. Lee, H. Kim, and H. Cho, "Development of an Ubiquitous Healthcare System based on Health Information Exchange Standards," Journal of Korean Institute of Intelligent Systems, Vol. 22, No. 3, pp. 273-280, Jun. 2012. (in Korean) https://doi.org/10.5391/JKIIS.2012.22.3.273
  3. K. Lee, S. Han, J. Park, J. Lee, and K. Kang, "ECG Monitoring System using QRS Detection Algorithm," Proc. of the 40th KIISE Fall Conference, pp. 371-373, 2013. (in Korean)
  4. U. Varshney, "Pervasive healthcare and wireless patient monitoring," Mobile Networks and Applications, Vol. 12, No. 2-3, pp. 113-127, Jul. 2007. https://doi.org/10.1007/s11036-007-0017-1
  5. E. Reilent, A. Kuusik, and M. Puju, "Real-Time Data Streaming for Functionally Improved eHealth Solutions," Proc. of the BHI 2012, pp. 140-143, Jan. 2012.
  6. M. V. Ramesh, S. Anand, and P. Rekha, "A Mobile Software for Health Professionals to Monitor Remote Patients," Proc. of the 9th WOCN, pp. 20-22, Sept. 2012.
  7. Health Level Seven. [Online]. Available: http://www.hl7.org
  8. J. Choi, S. Yoo, H. Park, and J. Chun, "MobileMed: A PDA-Based Mobile Clinical Information System," IEEE Transactions on Information Technology in Biomedicine, Vol. 10, No. 3, pp. 627-635, Jul. 2006. (in Korean) https://doi.org/10.1109/TITB.2006.874201
  9. M. Yuksel and A. Dogac, "Interoperability of Medical Device Information and the Clinical Applications: An HL7 RMIM based on the ISO/IEEE 11073 DIM," IEEE Transactions on Information Technology in Biomedicine, Vol. 15, No. 4, pp. 557-566, Jul. 2011. https://doi.org/10.1109/TITB.2011.2151868
  10. T. Namli, G. Aluc, and A. Dogac, "An Interoperability Test Framework for HL7-Based Systems," IEEE Transactions on Information Technology in Biomedicine, Vol. 13, No. 3, pp. 389-399, May 2009. https://doi.org/10.1109/TITB.2009.2016086
  11. Y. Park and H. Cho, "Exchange Method of the HL7 Message using Open Source on OSGi Environment," Journal of KISS : Computing Practices, Vol. 18, No. 11, pp. 775-779, Nov. 2012. (in Korean)
  12. S. Heo, S. W. Choi, G. Kim, and A. Oh, "The Study on HL7 Message Improvement for Supporting of Efficient Healthcare Service," Journal of Korea Information and Communication Society, Vol. 18, No. 6, pp. 1388-1394, Jun. 2014. (in Korean) https://doi.org/10.6109/jkiice.2014.18.6.1388
  13. G. Kim and S. Lim, "The Web Viewer System Development of Real-Time Patient Monitoring using HL7(Healthy Level Seven) Protocol," Journal of the Korea Institute of Information and Communication Engineering, Vol. 13, No. 3, pp. 546-555, Mar. 2009. (in Korean)
  14. T. Tran, H. Kim, and H. Cho, "A Development of Ubiquitous Biomedical Interface for Facilitating Medical Device Connectivity," Proc. of the 7th CIT, pp. 1094-1099, Oct. 2007.
  15. J. Jeon, "A Design and Implementation of Smart Healthcare System based on ISO/IEEE 11073 and HL7," PhD dissertation, Department of Computer Sciences 2013. (in Korean)
  16. D. Hwang, "Implementation of HL7 Interface Engine for Medical Information Exchange," Journal of The Korea Society of Computer and Information, Vol. 15, No. 3, pp. 89-98, Aug. 2010. (in Korean) https://doi.org/10.9708/jksci.2010.15.8.089
  17. HL7 OBX - Observation Segment. [Online]. Available: http://www.corepointhealth.com/resource-center/hl7-resources/hl7-obx-segment
  18. K. Lee, J. Park, and K. Kang, "Development of a Tele-Healthcare System based on the HL7 Standard," 18th IEEE International Symposium on Consumer Electronics, pp. 1-2, 2014. (in Korean)
  19. MIT-BIT Arrhythmia database. [Online]. Available: http://www.physionet.org/physiobank/database/mitdb/
  20. HAPI project. [Online]. Available: http://hl7api.sourceforge.net/
  21. HL7 Escape Sequences | HL7 Standards. [Online]. Available: http://www.hl7standards.com/blog/2006/11/02/hl7-escape-sequences/
  22. HAPI - HAPI TestPanel. [Online]. Available: http://hl7api.sourceforge.net/hapi-testpanel/
  23. Y. Kim, W. Kang, K. Cho, and J. Son, "Design of HL7 Message based Healthcare System with Mobile Devices," Proc. of HCI Korea 2013, pp. 1088-1090, 2013. (in Korean)