• Title/Summary/Keyword: ECG measurement

Search Result 220, Processing Time 0.033 seconds

Evaluation of Two-Dimensional Space of Human Sensibility Mutation by IAPS (IAPS 사진을 이용한 이차원 공간의 감성 변화 평가)

  • 민병찬;정순철;강인형;최지연;김철중
    • Science of Emotion and Sensibility
    • /
    • v.6 no.2
    • /
    • pp.21-28
    • /
    • 2003
  • Tn the present study, 9 photographs from the International Affective Picture System (IAPS) judged to express best 2-dimensional sensibility were selected and used to stimulate the subjects. The goal of the study lay in verifying whether or not the consequent affective changes in the subjects can be discriminated psychologically and physiologically in terms of arousal and relaxation. In order to determine affective changes, the physiological signals of the subjects' autonomic nervous system were measured through electrocardiogram (ECG) , galvanic skin response (GSR), skin temperature, and respiration. After stimulation and measurement, subjective evaluation was conducted. Subjective evaluation revealed that affective arousal level could be classified into 4 consecutive stages: arousal 〉 unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. Analysis revealed that the responses of the autonomic nervous system, too, could be classified into 3 consecutive stages: arousal, unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. By selecting and using 9 photographs from the IAPS deemed best to express Koreans'2-dimensional sensibility, the present study confirmed that it is possible to discriminate changes in the subjects' affective arousal level in terms of arousal and relaxation through psychological and physiological evaluation.

  • PDF

The Recognition Method for Focus Level using ECG(electrocardiogram) (심전도를 이용한 집중도 인식 방법)

  • Lee, Dong Won;Park, Sangin;Whang, Mincheol
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.370-377
    • /
    • 2018
  • Focus level has been important mental state in user study. Cardiac response has been related to focus and less clarified. The study was to determine cardiac parameters for recognizing focus level. The sixty participants were asked to play shooting game designed to control two focus levels. Electrocardiogram was measured during task. The parameters of time domain and frequency domain were determined from ECG. As a result of independent t-test, RRI, SDNN, rMSSD and pNN50 of time domain indicator were statistically significant in recognizing focus level. LF, HF, lnLF and lnHF of frequency domain were observed to be significant indicator. The rule base for recognition has been developed by the combination of RRI, rMSSD and lnHF. The rule base has been verified from another sixty data samples. The recognition accuracy were 95%. This study proposed significant cardiac indicators for recognizing focus level. The results provides objective measurement of focus in user interaction design in the fields of contents industry and service design.

A Comparative Study on the Conductivity and Physical Properties of Conductive Materials for Heart Rate Monitoring (심박 모니터링을 위한 전도성 소재의 전도성 및 물성 비교 연구)

  • Kim, Jimin;Kim, Jongjun
    • Journal of Fashion Business
    • /
    • v.22 no.4
    • /
    • pp.118-129
    • /
    • 2018
  • The purpose of this study is to develop ECG electrode materials for the heart rate monitoring smart band, a smart device used for ECG and heart rate measurement. The purpose of the evaluation is to assess properties and conductivity of electrodes of the existing heart rate monitoring smart band, and to determine suitability through a representative conductive sample. Because level of thickness does not differ significantly from value of conductive specimen from thickness of the smart band, it can be used as a conductive electrode. Surface conductivity of conductive samples and smart bands, is expected to be available as electrodes except for conductive film. Also, since the knit have conductivity only in the metal processing layer, it is necessary to use electrodes on the part of the metal processing layer that is conductive when applying the knit. Tensile strength and electrical conductivity of the tensile were generally revealed to have a tendency. Thickness of the specimen that can be used as an electrode for the smart band is suitable for all samples, electrical resistance, conductive woven, conductive knit, and conductive cord. In the case of conductive cord, however, the electrode attached to the human body will not conform to the flat shape of the electrode attached to the human body. Therefore, the conductive woven and the conductive knit will be available as an electrode.

Measurement of Emotional Transition Using Physiological Signals of Audiences (관객의 생체신호 분석을 통한 감성 변화)

  • Kim, Wan-Suk;Ham, Jun-Seok;Sohn, Choong-Yeon;Yun, Jae-Sun;Lim, Chan;Ko, Il-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.168-176
    • /
    • 2010
  • Audience observing visual media with care experience lots of emotional transition according to characteristics of media. Enjoy, sadness, surprising, etc, a variety of emotional state of audiences is often arranged by James Russell's 'A circumplex model of affect' utilized on psychology. Especially, in various emotions, 'Uncanny' mentioned by Sigmund Freud is represented a sharp medium existing in a crack of clearly emotional conception. Uncanny phenomenon is an emotional state of changing from unpleasant to pleasant on an audience observing visual media is been aware of immoral media generally, therefore, because this is a positive state on a social taboo, we need to analyze with a scientific analysis clearly. Therefore, this study will organize James Russell's 'A circumplex model of affect' and uncanny phenomenon, will be progressed to establish a hypothesis about a state of uncanny on audiences observing visual media and analyze results of the physiological signals experiment based on ECG(Electronic Cardiogram), GSR(Galvanic Skin Response) signals with distribution, distance, and moving time in a circumplex model of affect.

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

Biometrics System Technology Trends Based on Biosignal (생체신호 기반 바이오인식 시스템 기술 동향)

  • Choi, Gyu-Ho;Moon, Hae-Min;Pan, Sung-Bum
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.381-391
    • /
    • 2017
  • Biometric technology is a technology for authenticating a user using the physical or behavioral features of the inherent characteristics of the individual. With the necessity and efficiency of the technology in the fields of finance, security, access control, medical welfare, inspection, and entertainment, the service range has been expanding. Biometrics using biometric information such as fingerprints and faces have been exposed to counterfeit and disguised threats and become a social problem. Recent studies using a bio-signal from the inside of the body other than the bio-information of the external body are being developed. This paper analyzes the recent research and technology of biometric systems using bio-signals, ECG, heart sounds, EEG, and EMG to present the skills needed for the development direction. In the future, utilizing the deep learning to build and analyze database to manage bio-signal based big data for the complex condition of individuals, biometrics technologies suitable for real time environment are expected to be researched.

Analysis of the Optimal Location of Wearable Biosensor Arrays for Individual Combat System Considering Both Monitoring Accuracy and Operational Robustness (모니터링 정확도와 운용 강건성을 고려한 개인전투체계용 착용형 생체센서 어레이의 최적 위치 분석)

  • Ha, Seulki;Park, Sangheon;Lim, Hyeoncheol;Baek, Seung Ho;Kim, Do-Kyoung;Yoon, Sang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.287-297
    • /
    • 2019
  • Monitoring for the physiological state of a solider is essential to the realization of individual combat system. Despite all efforts over the last decades, there is no report to point out the optimal location of the wearable biosensors considering both monitoring accuracy and operational robustness. In response, we quantitatively measure body temperature and heartrate from 34 body parts using 2 kinds of biosensor arrays, each of which consists of a thermocouple(TC) sensor and either a photoplethysmography(PPG) sensor or an electrocardiography(ECG) sensor. The optimal location is determined by scoring each body part in terms of signal intensity, convenience in use, placement durability, and activity impedance. The measurement leads to finding the optimal location of wearable biosensor arrays. Thumb and chest are identified as best body parts for TC/PPG sensors and TC/ECG sensors, respectively. The findings will contribute to the successful development of individual combat system.

A Method to Separate Respiration and Pulse Signals from BCG Sensing Data for Companion Animals

  • Kwak, Ho-Young;Chang, Jin-Wook;Kim, Soo Kyun;Song, Woo Jin;Yun, Young-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.2
    • /
    • pp.163-170
    • /
    • 2022
  • Currently, as the number of families living with companion animals increases, the demand for information about the health status of companion animals has increased. As the demand for this increases, there is a need for a method to measure respiration and pulse in companion animals. Considering the characteristics of hairy companion animals, we want to measure respiration and pulse signals using BCG, which is different from adsorption ECG. Since this BCG method is made by mixing respiration and pulse signals into one signal, it is necessary to separate the respiration signal waveform and the pulse signal waveform from one signal waveform. In this paper, a wearable device for BCG measurement was implemented to measure the signal, and a method of separating the signal input from the BCG wearable device into a respiration signal and a pulse signal was proposed.

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF