• Title/Summary/Keyword: EAN

Search Result 86, Processing Time 0.026 seconds

Frost Heave of Frost Susceptible Soil According to Performance of Thermo-syphon (열 사이펀 성능에 따른 동상민감성 지반의 거동 비교)

  • Park, Dong-Su;Shin, Mun-Beom;Seo, Young-Kyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.27-40
    • /
    • 2021
  • The construction method to prevent the frost heave or thaw settlement is called the ground stabilization method, and the thermo-syphon is one of the typical ground stabilization methods. The thermo-syphon has recently been developed with a simple analysis model and thermal analysis has been carried out, but the frost heave of frost susceptible soil was not considered. This study was conducted using ABAQUS internal user subroutine to develop the numerical analysis model (Coupled thermo-mechanical) that can simultaneously perform thermal analysis for the temperature change of the soil according to the thermo-syphon and structural analysis to predict the frost heave of the soil accordingly. As a result of the numerical analysis, the frost heave of the soil decreased as the performance of the thermo-syphon increased. As for the main results, when the thermo-syphon which has contain 25%, 50%, and 100% of refrigerant filling ratio was applied, the reduction ratio of the frost heave was 5.5%, 14.4%, and 21% respectively.

A Study on the Layout of Master File of POS for Apparel Industry (국내 의류산업의 POS 시스템 사용 실태에 관한 연구)

  • 조진숙;차주희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.4
    • /
    • pp.451-462
    • /
    • 2000
  • This study is to investigate the current use of POS system in Korean clothing industry, so that we can make suggestions for better use of it. We interviewd companies using POS systems as well as EAN Korea which is in charge of POS data processing. As a results. we found out that standard KAN code has severe difficulties to cope with the diversity of the information which is necessary in clothing industry. Therefore we are making some suggestions to use KAN code as a recognizing code for more structured master data file for extremely diverse clothing items.

  • PDF

A combustion control modeling of coke oven by Swarm-based fuzzy system (스왐기반 퍼지시스템을 이용한 코크오븐 연소제어 모델링)

  • Ko, Ean-Tae;Hwang, Seok-Kyun;Lee, Jin-S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.493-495
    • /
    • 2005
  • This paper proposes a swarm-based fuzzy system modeling technique for coke oven combustion control diagnosis. The coke plant produces coke for the blast furnace plant in steel making process by charging coal into oven and supplying gas to carbonize it. A conventional mathematical model for coke oven combustion control has been used to control the amount of gas input, but it does not work well because of highly nonlinear feature of coke plant. To solve this problem, swarm-based fuzzy system modeling technique is suggested to construct a diagnosis model of coke oven combustion control. Based on the measured input-output data pairs, the fuzzy rules are generated and the parameters are tuned by the PSO(Particle Swarm Optimizer) to increase the accuracy of the fuzzy system is operated. This system computes the proper amount of gas input taking the operation conditions of coke oven into account, and compares the computed result with the supplied gas input.

  • PDF

Insulation Performance Evaluation of Apartment Housing Bying a Three-Dimensional Steady State Simulation (3차원 정상상태 해석에 의한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon;Lee, Yong-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.730-735
    • /
    • 2009
  • The purpose of this study is to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. In this study, the three corners, weak part in condensation, were conducted by three-dimensional steady state simulation. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment buildings has serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. So, it is considerate to need a concrete technology improvement.

  • PDF

A Study of Effects of Ferritic Nitrocarburized Brake Disc on Its Corrosion Resistance and Braking Performances (브레이크 디스크의 산질화처리가 부식지연 및 제동특성에 미치는 영향에 관한 연구)

  • Han, Jin;Kim, Gwang Yun;Lee, Hack Ean;Lee, JeongJoo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.2
    • /
    • pp.19-24
    • /
    • 2015
  • Ferritic Nitro Carburizing (FNC) cast iron brake discs is known to improve corrosion resistance and brake creep groan noise as well as prevent corrosion-induced pulsation. But, it is necessary to treat honing machining on braking surface to avoid grinding noise during braking.

An Adaptive Watermarking Method for Copy Protectionof Digital Images (디지츨 영상의 복사 방지를 위한 적응 워터마킹 방법)

  • 김덕령;박성한
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.4
    • /
    • pp.85-95
    • /
    • 1998
  • In this paper, a new watermarking method for a copy protectionof images is proposed. The proposed method adaptively embeds a watermark in the frequency domain of images using human visual system model. For this purpose, the Just Noticeable Differences(JNDs) of each frequency coeffeicient value of a luminance plane is first found using Watson and Solomon's visual system model. An invisible maximum watermark value with is different in every position according to the characteristics of images is determined usig JND and Minkowski metric. A low frequency domain is divided into two sets based on a PN-sequence to protect thewatermark from the attack. The watermarks are added to one set of coefficients and detecting a watermark, the difference between the mean values of absolute coefficient values of both sets is calculated. The embedded watermark is tested using statistical hypothesis based on test static dertermined by the ean difference. To demonstrate the perfromance of the proposed method, the new watermarking method is applied to a high frequency image and low frequency images. Experimenatal results show the watermark is invisible and robust to JPEGlossy compression and noise.

  • PDF

A Study on Improving Dewaterability and Determining Optimum Condition of Digested Sludge Using Limestone (석회석을 이용한 소화슬러지 탈수성 개선 및 최적조건 결정에 관한 연구)

  • Kim, Ean-Ho;Seo, Jeoung-Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.239-244
    • /
    • 2004
  • The purposes of this study were to examine applicability of limestone as a conditioning agent and to determine the optimum conditions for improving dewaterability of digested sludge. The optimum conditions for temp., pH, dosage, particle size, time, and pressure was $30^{\circ}C$, 7, 45 g/l, 100 mesh, 30 min., and $2.66 {\times} 10^4 N/m^2$, respectively. On the basis of induced optimum conditions, if adding limestone in digested sludge, it estimated that its specific resistance was $1.43 {\times} 1012 m/kg$. Therefore, it seemed that we could utilize limestone as conditioning agent for improving dewaterability of digested sludge.

A Study on Modal Analysis of a Large Structural System with Contribution Factor Analysis of Substructures (부분구조의 기여도 분석을 통한 대형구조물의 해석에 관한 연구)

  • Cho, Ean-Soo;Baik, Serl;Yim, Hong-Jae;Kim, Hyo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.341-348
    • /
    • 2001
  • In this study, a method is presented to find out a relationship between modes of a substructure and those of the system structure. Superelement analysis is performed for a full vehicle system, where the bus is partitioned by six parts. In this study, Modal Assurance Criteria(MAC) which is to represent the correlation between two mode shapes is used to investigate the contribution factor of each substructure for the full system. The proposed participation factor can be used for design of substructures to meet the design target of the total structural system.

  • PDF

Optimum Conditions of Super-critical Water Oxidation Process for Treatment of Slurry Piggery Wastewater (슬러리형 돈사분뇨처리를 위한 초임계수 산화공정의 최적 조건)

  • Kim, Ean-Ho;Seo, Jeoung-Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.333-341
    • /
    • 2008
  • In this study, the possibility and the optimal conditions for treating slurry type piggery wastewater using supercritical water oxidation were tested in the laboratory. The results could be summarized as follows; The slurry type piggery wastewater, which was diluted 50 times, was treated most effectively at the pressure of 300 bar, the temperature of $550^{\circ}C$ and the residence time of 10 minutes. The air saturated water was injected, as an oxidizing agent, and the removal efficiencies of $COD_{Cr}$, T-N, $NH_4^+$-N and T-Pattheoptimal conditions were 92, 40, 59 and 100%, respectively. Therefore, analte rnativemea suremu stbetaken to improve theremo valefficiency of the nitrogen compounds.

Effect of Building and Green on Outside Thermal Environment (건물과 녹지배치가 외부 열환경 변화에 미치는 영향 분석)

  • Son, Won-Tug;Choi, Hyun-Sang;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2010
  • Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we use CFD simulation in order to analyze quantitative effects by placing a Building and Green on the heat island phenomenon in urban area. The present study quantitatively analyzes the Urban Heat Island Effects, Outdoor air temperature, and Humidity and air flow.

  • PDF