• Title/Summary/Keyword: E1 pulse

Search Result 333, Processing Time 0.04 seconds

Analysis and Performance Improvement of Integrated E1 Pulse Generator for EMP Protection Performance Test (EMP 방호성능 시험용 통합형 E1 펄스 발생장치 분석 및 성능 개선)

  • Kim, Young-Jin;Kang, Ho-jae;Jeong, Young-Kyung;Youn, Dong-Gi;Park, Yong Bae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.415-423
    • /
    • 2018
  • We herein investigate the E1 pulse for evaluating the conducted performance of transmission lines connected to the electromagnetic pulse protection facilities against a conducted high-altitude electromagnetic pulse threat exposed to an external electromagnetic environment. The existing E1 pulse generator uses the Marx generator high-voltage step-up method; however, in this research, we used the Tesla transformer method to easily change the broadband output voltage(30 to 350 kV). We also analyzed the controller, power supply, high-voltage booster, and pulse-shaping device. The E1 pulse performance using the Tesla transformer was predicted through simulations and validated by measurements.

Response Characteristic Analysis of ZnO Varistors by the Conductive E1 Pulse (전도성 E1 펄스에 대한 ZnO 바리스터의 동작특성 분석)

  • Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.241-245
    • /
    • 2019
  • This work presents the response characteristics of a ZnO varistor to conductive EMP. An E1 pulse, standardized to MIL-STD-188-125-1, was applied to the varistors wherein the residual current and response times were measured with the applied E1 pulse current. Additionally, the response time was measured according to the length of the connection path. Consequently, the amplitude of the residual voltage through the ZnO varistors was increased with increasing amplitude of the applied E1 pulse current. As the length of the connection path increased, the operating response time and residual peak voltage also increased. These results indicate that the response characteristics of ZnO varistors can be applied to basic data to support the use of varistors as a protective measure against conductive EMP.

Chemical Properties of Cu( II ) Compound Containing Endocrine Disrupter, Bis-Phenol A

  • Park, Chil-Nam
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.121-126
    • /
    • 2001
  • The techniques of pulse and cyclic voltammetry were applied to the determination of (E$_{1}$2)$_2$-(E$_{1}$2)$_1$ for two-step electrochemical charge transfers. In addition, a simple amplitude was derived far the dependence of the differential pulse response on (E$_{l}$ 2/)$_1$ and (E$_{1}$2/)$_2$. and the use of peak to peak separation in cyclic voltammetry and differential pulse methods was evaluated. A comparison of the comproportionation constants(Ke) from differential pulse and cyclic voltammetry methods exhibited a good agreement within 5%.

  • PDF

A Study on the Environmental Hormone

  • Chil Nam, Choi;Eun Jung, Na
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.05a
    • /
    • pp.193-194
    • /
    • 2001
  • To determine for the hybridization, we have investigated by UV spectroscopic method. This complex behavior as nonelectrolytes in polar aprotic solution with molar conductivities. The technoques of pulse and cyclic voltammetry have been applied to the determination of $(E_{1/2})_{2}$-$(E_{1/2})_{1}$ for two-step electrochemical charge transfers. A simple amplitude has been derived for the dependence of the differential-pulse response on $(E_{1/2})_{1}$ and $(E_{1/2})_{2}$. The use of the peak-to-peak separation in cyclic voltammetry has also been evaluated. Comparison with a differential pulse and cyclic voltammetry methods shows agreement of comproportionation constant$(K_{c})$ within 50%.

  • PDF

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

SOx and NOx removal performance by a wet-pulse discharge complex system (습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성)

  • Park, Hyunjin;Lee, Whanyoung;Park, Munlye;Noh, Hakjae;You, Junggu;Han, Bangwoo;Hong, Keejung
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

Pulse electric field-excited electron emission from Pb$(Zr_xTi_{1-x})O_3$ ceramics prepared by conventional solid state reaction (고상 반응법에 의해 제조된 Pb$(Zr_xTi_{1-x})O_3$ 세라믹스에서 펄스 전계에 의한 전자 방출)

  • Kwak, Sang-Hee;Kim, Tae-Heui;Park, Kyung-Bong;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1867-1869
    • /
    • 1999
  • Pulse electric field induced electron emission from ferroelectrics has been studied with Pb$(Zr_xTi_{1-x})O_3$ ceramics with varying Zr/Ti ratio from 35/65 to 65/35, Electron emission was proved to be concentrated on the electrode edge by emission profile test and emission capture photographs. The 65/35 composition showed largest emission charge in lowest field and lowest emission threshold field. The emission characteristics are closely dependent on their ferroelectric properties in hysteresis curve. Electron emission charge increases with the polarization charge and emission threshold voltage is dependent on coercive field regardless of their composition. But dielectric constant has little relation with emission property. Electron emission charge increases exponentially with pulse electric field irrespective of composition. On the assumption that the surface potential is linear with the pulse electric field, electron emission can be regarded as a field emission at the electrode edge using Fowler-Nordheim plot of ln$(Q_e/E_{fe})$ to $1/E_{fe}$.

  • PDF

Performance Analysis of M-ary Impulse Communications over AWGN Channels (AWGN 채널에서 M진 임펄스 통신의 성능 분석)

  • 김동호;백승선;문용규;강희조
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.559-562
    • /
    • 2002
  • 본 논문에서는 최근 제한적으로 사용이 승인된 UWB(초광대역: Ultra-Wideband) 통신을 AWGN 하에서 다중 접속을 고려하지 않은 단일 사용사일 경우로 가정시, M진 값이 변화함에 따른 에러율과 성능 개선 기법으로 BCH를 채용시의 에러율을 비교 분석하였다. 기존에 연구되어 오던 변조로 PAM(Pulse Amplitude Modulation)과 PPM(Pulse Position Modulation)방식을 비교하였으며 에러율 $10^{-6}$을 기준으로 M=2, 4일 경우 PAM이 PPM보다 약 E$_{b}$/N$_{o}$ =3~4[dB], M=8 이상의 경우 PPM이 약 E$_{b}$/N$_{o}$ =9[dB], M=16일 경우 약 E$_{b}$/N$_{o}$ =15[dB]정도 성능이 우수하였다. AWGN 채널 하에서 에러 정정 부호인 BCH(15,7)를 도입하였을 경우 에러율 $10^{-6}$을 기준으로 PAM방식은 약 E$_{b}$/N$_{o}$ 가 약 1[dB], PPM 방식은 M=2, 4일 경우 약 E$_{b}$/N$_{o}$ =1~1.5[dB]정도 개선되었다.

  • PDF

Analysis of LDC Message Reception Performance of Korean eLoran Pilot Service according to Modulation Methods (첨단 지상파항법시스템(eLoran) 시범서비스의 LDC 메시지 변조기법에 따른 수신성능 분석)

  • Pyo-Woong, Son;Sak, Lee;Tae Hyun, Fang;Kiyeol, Seo
    • Journal of Navigation and Port Research
    • /
    • v.46 no.6
    • /
    • pp.525-529
    • /
    • 2022
  • In the eLoran system, the Loran Data Channel (LDC) is used to provide precise timing and positioning. The LDC message can be modulated with the Eurofix method, which modulates the transmission time of the 3rd-8th pulse not used for navigation, and the 9th pulse method, which modulates data using the 9th additional pulse after the existing 8 Loran pulses. In this paper, we analyzed the reception performance of the LDC message transmitted from the eLoran transmitter according to the modulation method. The eLoran testbed transmitter in Incheon was set to transmit LDC messages simultaneously with the 9th pulse modulation method and the Eurofix modulation method. Then, the LDC messages stored in the databases of the eLoran differential stations in Incheon and Pyeongtaek were analyzed in terms of the message reception rate according to the modulation method. Using the navigation aid management ship Inseong No. 1, the range of LDC message reception of actual sea users near Incheon Port was also analyzed. The results of this study are expected to be utilized in the full operational capability service after the eLoran pilot service.