• Title/Summary/Keyword: E.coil

Search Result 311, Processing Time 0.036 seconds

A Joining Method between HTS Double Pancake Coils (고온초전도 더블 팬케이크 코일들 사이의 접합 방법)

  • Sohn, Myung-Hwan;Sim, Ki-Deok;Kim, Seok-Ho;Kim, Hae-Jong;Bae, Joon-Han;Lee, Eon-Young;Min, Chi-Hyun;Seong, Ki-Chul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

The Performance of Micro Fluxgate Sensor with Magnetic Core Shape (자성체 코어 형상에 따른 마이크로 플럭스게이트 센서의 검출 특성)

  • 조중희;최원열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.508-514
    • /
    • 2004
  • A fluxgate magnetic sensor consists of a solenoid excitation coil, pick-up coil, and magnetic core. We presents the effect of magnetic core shape in a micromachined fluxgate sensor. To observe the performance of fluxgate sensor with magnetic core side width and gap, side width of 125 ${\mu}{\textrm}{m}$, 250 ${\mu}{\textrm}{m}$, and 500 ${\mu}{\textrm}{m}$ were designed in a rectangular-ring shaped core and the gaps of 0 ${\mu}{\textrm}{m}$, 50 ${\mu}{\textrm}{m}$, and 100 ${\mu}{\textrm}{m}$ were also fabricated in a racetrack shaped core. The solenoid coils and magnetic core were separated by benzocyclobutane(BCB) which had high insulation and good planarization characters. Copper coil patterns of 10 ${\mu}{\textrm}{m}$ width and 6${\mu}{\textrm}{m}$ thickness were electroplated on Ti(300 $\AA$) / Cu(1500 $\AA$) seed layers. 3 ${\mu}{\textrm}{m}$ thick N $i_{0.8}$F $e_{0.2.}$(permalloy) film for the magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The magnetic core had the high DC effective permeability of ∼1,300 and coercive field of ∼0.1 Oe. Because the magnetic cores of 500 ${\mu}{\textrm}{m}$ side width and 0 gap had a low magnetic flux leakage, high sensitivity of ∼350 V/T were measured at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. The power consumption of ∼14 ㎽ was measured. The fabricated fluxgate sensor had the very small actual size of 3.0${\times}$1.7 $\textrm{mm}^2$. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.m.m.m.

Optimization of Etching Profile in Deep-Reactive-Ion Etching for MEMS Processes of Sensors

  • Yang, Chung Mo;Kim, Hee Yeoun;Park, Jae Hong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.10-14
    • /
    • 2015
  • This paper reports the results of a study on the optimization of the etching profile, which is an important factor in deep-reactive-ion etching (DRIE), i.e., dry etching. Dry etching is the key processing step necessary for the development of the Internet of Things (IoT) and various microelectromechanical sensors (MEMS). Large-area etching (open area > 20%) under a high-frequency (HF) condition with nonoptimized processing parameters results in damage to the etched sidewall. Therefore, in this study, optimization was performed under a low-frequency (LF) condition. The HF method, which is typically used for through-silicon via (TSV) technology, applies a high etch rate and cannot be easily adapted to processes sensitive to sidewall damage. The optimal etching profile was determined by controlling various parameters for the DRIE of a large Si wafer area (open area > 20%). The optimal processing condition was derived after establishing the correlations of etch rate, uniformity, and sidewall damage on a 6-in Si wafer to the parameters of coil power, run pressure, platen power for passivation etching, and $SF_6$ gas flow rate. The processing-parameter-dependent results of the experiments performed for optimization of the etching profile in terms of etch rate, uniformity, and sidewall damage in the case of large Si area etching can be summarized as follows. When LF is applied, the platen power, coil power, and $SF_6$ should be low, whereas the run pressure has little effect on the etching performance. Under the optimal LF condition of 380 Hz, the platen power, coil power, and $SF_6$ were set at 115W, 3500W, and 700 sccm, respectively. In addition, the aforementioned standard recipe was applied as follows: run pressure of 4 Pa, $C_4F_8$ content of 400 sccm, and a gas exchange interval of $SF_6/C_4F_8=2s/3s$.

Design and Fabrication of Racetrack type High Tc Superconducting Magnet for the Superconducting Rotating Machine (초전도회전기용 래이스트랙형 고온초전도 마그네트 설계 및 제작)

  • Sohn, M.H.;Baik, S.K.;Jo, Y.S.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.3-5
    • /
    • 2001
  • Racetrack coils are used in many areas of superconductivity applications such as generators, motors, maglev, wiggler magnets and so on. The fabrication and characteristics of race-track type High Tc Superconducting (HTS) magnets were carried out. The Magnet is composed of 3 pancake coils wound by 37-filamental Bi-2223/ Ag-alloy tapes. Quench current ($I_q$) of both whole magnet and 3 pancake coils were measured. At 77K under the self-field, $I_q$ of magnet was 12A, while in the case of middle pancake coil, $I_q$ was 15A. The upper pancake coils of racetrack magnet with iron plates, magnet having optimized current distribution and initial magnet are compared with each other through 3D FEA, manufacturing and testing these magnets. The measured performance of the upper pancake coil #3 with iron plates improved by 50% on the basis of initial pancake coil #3. Quench current ($I_q$) of field winding was 12A. In addition, the fabrication processes and the characteristics of HTS magnet are described.

  • PDF

Hisrological Alterations and Immune Response Induced by Pet Toxin During Colonization with Enteroaggregative Escherichia coil (EAEC) in a Mouse Model Infection

  • Eslava, Carlos;Sainz, Teresita;Perez, Julia;Fresan, Ma.Cristina;Flores, Veronica;Jimenez, Luis;Hernandez, Ulises;Herrera, Ismael
    • Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.91-97
    • /
    • 2002
  • Enteroaggregative E. coil (EAEC) is an important aethiological causal agent of diarrhea in people of developed and undeveloped countries. Different in vitro and in vivo models have been proposed to study the pathdgenic and immune mechanisms of EAEC infaction. The aim of this study was to analyze whether BALB/c mice could be used as an animal model to study EAEC pathogenesis Six-week-old BALB/c mice were inoculated with EAEC strain 042 (044:H88) nalidixic acid resistant, and re-inoc-ulated ten days after. Mice feces were monitored for the presence of the EAEC strain over a period of 20 days . Bacteria were enumerated on MacConkey agar containing 100$\mu$g of nalidixic acid per ml. Results showed that 35% of the animals were colonized for 3 days, 15% for 5 and 10% for more than 7 days . After re-inoculation only 16% of the animals remained colonized for more than 3 days. During the necropsy, the intestinal fluid of same of the infected animals presented mucus and blood. Six of these fluids showed the presence of IgA antibodies againset Pet toxin and IgG natibodies raised against the toxin were also detected in the animal serum. Histopathologic evidence confirms the stimulation of mucus hypersecretion, an increased amount of goblet cells and the presence of bacterial aggregates in the apical surfaces of intestinal epithelial cells. Edema was present in the submucosa. These results suggest that BALB/c mice could be used as an animal model for in vivo study of EAEC infection.

Correlation between contrast leakage period of procedural rupture and clinical outcomes in endovascular coiling for cerebral aneurysms

  • Sung-Tae Kim;Sung-Chul Jin;Hae Woong Jeong;Jin Wook Baek;Young Gyun Jeong
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.420-428
    • /
    • 2023
  • Objective: Intraprocedural rupture (IPR) is a fatal complication of endovascular coiling for cerebral aneurysms. We hypothesized that contrast leakage period may be related to poor clinical outcomes. This study aimed to retrospectively evaluate the relationship between clinical outcomes and contrast leakage period. Methods: Data from patients with cerebral aneurysms treated via endovascular coiling between January 2010 and October 2018 were retrospectively assessed. The enrolled patient's demographic data, the aneurysm related findings, endovascular treatment and IPR related findings, rescue treatment, and clinical outcome were analyzed. Results: In total, 2,859 cerebral aneurysms were treated using endovascular coiling during the study period, with IPR occurring in 18 (0.63 %). IPR occurred during initial frame coiling (n=4), coil packing (n=5), stent deployment (n=7), ballooning (n=1), and microcatheter removal after coiling (n=1). Tear sites included the dome (n=14) and neck (n=4). All IPRs were controlled and treated with coil packing, with or without stenting. Flow arrest of the proximal balloon was not observed. Temporary focal neurological deficits developed in two patients (11.1%). At clinical follow-up, 14 patients were classified as modified Rankin Scale (mRS) 0, three as mRS 2, and one as mRS 4. The mean contrast leakage period of IPR was 11.2 min (range: 1-31 min). Cerebral aneurysms with IPR were divided into late (n=9, mean time: 17.11 min) and early (n=9, mean time: 5.22 min) control groups based on the criteria of 10 min of contrast leakage period. No significant between-group differences regarding clinical outcomes were observed after IPR (p=1). Conclusions: In our series, all patients with IPR were controlled with further coil packing or stenting without proximal balloon occlusion within 31 min of contrast leakage. There was no difference in clinical outcomes when the long contrast leakage period group and short contrast leakage period group were compared.

Total Synthesis and Expression in E, coli of a Gene Coding for Human Interleukin-2 (인간 인터루킨-2를 코드하는 유전자의 합성과 대장균에서의 발현)

  • 주재훈;강성만;송인선;권종범;한문희;나도선
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.3
    • /
    • pp.228-234
    • /
    • 1991
  • - A synthetic gene coding for human interleukin-2 (IL-2) was constructed from the oligonucleotides synthesized by an automatic DNA synthesizer. The nucleotide sequence of the synthetic gene was chosen considering the preferred codons of E. coEi by not changing the amino acid sequence of IL-2 polypeptide. The synthetic gene was expressed in E. coli by placing the gene under the control of the $\lambda$ PL promoter. IL-2 was produced in the E. coli cytoplasm in the form of inclusion bodies. The recombinant IL-2 showed growth promoting activity on the IL-2 dependent cell line.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

Study of Heat Transfer and Safety Evaluation for Heating Coils in the Fuel Tank of a Ship (선박 연료탱크 내 가온기의 열유동 및 안전성 평가에 관한 해석)

  • Moon, Jin-Gwon;Park, Jong-Chun;Kwon, Yoo-Hong;Yoo, Won-Seok;Ahn, Soo-Whan
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.22-30
    • /
    • 2010
  • The fuel tank of a ship is filled with heavy fuel oil (HFO) that has a very high viscosity. In order to inject the HFO into the engine easily, heating coils are usually installed inside the fuel tank to heat the HFO and lower its viscosity. Currently, several different types of heating coils are used, e.g., fin-type, bare-type, drum-type, and shell-and-tube-type. It is well known that the shell-and-tube-type heating coil has good performance and high efficiency. In this study, experiments were conducted to determine the heat transfer efficiencies of three different shell-and-tube-type heating coils. Heat transfer efficiency was evaluated by using FLUENT 6.3.26 software. Also, structural safety was assessed by using ANSYS.simulation software.

Design Considerations of 2-pole Synchronous Superconducting Rotating Machine (2극 초전도 동기기 설계법 고찰)

  • Baik, S.K.;Sohn, M.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.;Jo, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.865-867
    • /
    • 2001
  • Generally large synchronous rotating machines with 2 poles have more merits than the others with more than 2 poles Superconducting synchronous rotating machines also have the same tendency, but they have different structure from conventional ones because of no magnetic core inside of the rotor. As the result, design approaches of the superconducting field coils are also different, which would be classified into 2 types according to their coil shapes. The first one is race-track type and the other is saddle type Race-track type machines have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 2 poles. On the other hand saddle type machines correspond to conventional cylindrical generators with 2 poles used for large turbine system in power plants. In this paper several types of superconducting field coils are introduced for 2 pole superconducting machine design and then the feasibility of each type is considered. Moreover, based on the consideration. 1MVA superconducting generator(S.G.) with saddle type field coil is designed electromagnetically.

  • PDF