Abstract
The fuel tank of a ship is filled with heavy fuel oil (HFO) that has a very high viscosity. In order to inject the HFO into the engine easily, heating coils are usually installed inside the fuel tank to heat the HFO and lower its viscosity. Currently, several different types of heating coils are used, e.g., fin-type, bare-type, drum-type, and shell-and-tube-type. It is well known that the shell-and-tube-type heating coil has good performance and high efficiency. In this study, experiments were conducted to determine the heat transfer efficiencies of three different shell-and-tube-type heating coils. Heat transfer efficiency was evaluated by using FLUENT 6.3.26 software. Also, structural safety was assessed by using ANSYS.simulation software.