• 제목/요약/키워드: E. coil

검색결과 296건 처리시간 0.035초

Frequency-Domain Circuit Model and Analysis of Coupled Magnetic Resonance Systems

  • Huh, Jin;Lee, Wooyoung;Choi, Suyong;Cho, Gyuhyeong;Rim, Chuntaek
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.275-286
    • /
    • 2013
  • An explicit frequency-domain circuit model for the conventional coupled magnetic resonance system (CMRS) is newly proposed in this paper. Detail circuit parameters such as the leakage inductances, magnetizing inductances, turn-ratios, internal coil resistances, and source/load resistances are explicitly included in the model. Accurate overall system efficiency, DC gain, and key design parameters are deduced from the model in closed form equations, which were not available in previous works. It has been found that the CMRS can be simply described by an equivalent voltage source, resistances, and ideal transformers when it is resonated to a specified frequency in the steady state. It has been identified that the voltage gain of the CMRS was saturated to a specific value although the source side or the load side coils were strongly coupled. The phase differences between adjacent coils were ${\pi}/2$, which should be considered for the EMF cancellations. The analysis results were verified by simulations and experiments. A detailed circuit-parameter-based model was verified by experiments for 500 kHz by using a new experimental kit with a class-E inverter. The experiments showed a transfer of 1.38 W and a 40 % coil to coil efficiency.

완전이식형 인공심장 구동을 위한 무선에너지 전송시스템의 개발 (Transcutaneous Energy Transmission System Development for driving totally implantable total artificial heart)

  • 안재목;이우철;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.117-122
    • /
    • 1992
  • In systems in which inductive coupling between a pancake-shaped coil on the surface of the body and a similar coil within the body is utilized for the transfort of electromagnetic energy, the minimization of temperature rise in the tissue is intimately related to the achievement of minimum losses in the region of the implanted coil. The new class of amplifiers, named "class E", for inverter is defined and is illustrated by a detailed description and a set of desist equations for one simple member of the class. For TET circuit the authors measured 65 to 76 percent efficiency at 1985kHz at 30 to 50 W output from IRF250 MOSFET transistor.

  • PDF

중자장급 보급형 국산 초전도 MRI 마그네트 개발 (The Development of Popular type Domestic Superconducting MRI Magnet with Middle Magnetic Field Range)

  • 배준한;고락길;심기덕;진흥범;조전욱;이언용;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.22-25
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

레이스트랙형 초전도계자코일의 AE 신호 특성평가 (Investigation of Acoustic Emission Signals in Racetrack Superconducting Field Winding Coils)

  • 손명환;백승규;고락길;이언용;배준한;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.186-188
    • /
    • 1998
  • Acoustic emission monitoring on two racetrack superconducting field winding coil was performed during excitation and quenches to diagnose the integrity of the field winding coils. Two field windings were not impregnated with epoxy The results confirm that the acoustic emission signals are mainly due to conductor motions which cause premature quenching of the winding. The quench current of modified racetrack type field winding coil (Type B) are more higher than that of conventional field winding coil (Type A).

  • PDF

무전극 형광램프용 안테나 설계를 위한 전기적 특성 시뮬레이션 (Electrical Characteristics of Antenna for Electrodeless Fluorescent Lamp Using the Electromagnetic Simulation)

  • 허인성;김광수;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.61-64
    • /
    • 2004
  • Recently, the RF inductive discharge or inductively coupled plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. To the point of lighting sources, the electrodeless fluorescent lamps utilizing an inductively coupled plasma (ICP) have been objects of interest and research during the last decades, mainly because of their potential for extremely long life, high lamp efficacies, rapid power switching response. The electrodeless fluorescent lamp that is dealt with in this work comprises a bulb filled with rare gas and amalgam of vaporizable metal and has a coil provided with a winding around the ferrite. Current through a coil produces a magnetic field in the discharge space. The changing magnetic flux then produces an azimuthal electric field E around the coil, according to Faraday's laws of magnetic induction.

  • PDF

무전극 형광램프용 안테나 설계를 위한 전기적 특성 시뮬레이션 (Electrical Characteristics of Antenna for Electrodeless Fluorescent Lamp Using the Electromagnetic Simulation)

  • 허인성;김광수;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.285-288
    • /
    • 2004
  • Recently, the RF inductive discharge or inductively coupled plasma(ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. To the point of lighting sources, the electrodeless fluorescent lamps utilizing an inductively coupled plasma(ICP) have been objects of interest and research during the last decades, mainly because of their potential for extremely long life, high lamp efficacies, rapid power switching response. The electrodeless fluorescent lamp that is dealt with in this work comprises a bulb filled with rare gas and amalgam of vaporizable metal and has a coil provided with a winding around the ferrite. Current through a coil produces a magnetic field in the discharge space The changing magnetic flux then produces an azimuthal electric field E around the coil, according to Faraday's laws of magnetic induction.

  • PDF

선박 추진용 저속형 고온초전도 모터 설계 (Design of Low-speed High-temperature Superconducting Motor for Ship Propulsion)

  • 백승규;권영길;김호민;이재득;이언용;김영춘;문태선;박희주;권운식;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.947-948
    • /
    • 2007
  • A superconducting synchronous motor with rotating field coil has been designed. This rotating field coil is composed of high-temperature superconducting(HTS) wire but the stationary armature windings are composed of conventional copper wire. In this paper a 5MW class synchronous motor with rotating HTS coil is designed. This motor is aimed to be utilized for ship propulsion so it has very low-speed. Firstly an air-cored type has been designed, which does not have any iron core both at the field and at the armature teeth. Secondly several iron-cored rotor types are considered to reduce expensive HTS wire cost.

  • PDF

Pulsed field magnetization of multi-turn short-circuited stabilized double pancake HTS coil

  • Korotkov, V.S.;Krasnoperov, E.P.;Brazhnik, P.A.;Kartamyshev, A.A.;Bishaev, A.M.;Kozinsteva, M.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.1-5
    • /
    • 2019
  • The pulsed field magnetization of the short-circuited soldered double pancake coil made of stabilized commercial high-Tc superconductor (HTS) tape is experimentally studied. The evolution of the shielding current induced by the pulsed field and the trapped field after the pulsed magnetization was measured at 77 K. It is shown that the trapped field in the coil is close to the value reached in the field cooling process and reduces weakly at 5-fold increasing of pulsed field amplitude. The current relaxation at t~2 ms after the pulse is defined by the current sharing between the tape's copper coating and the $YBa_2Cu_3O_{7-d}$ layer. In the intermediate time scale (1 s < t < 100 s) the flux creep in HTS layer dominates. At t > 100 s the current's relaxation is defined by the resistance of soldered joint between tapes.

T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석 (Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP)

  • 임건규;이향범
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.159-165
    • /
    • 2008
  • 본 논문에서는 전자기 유한요소 해석을 통하여 배열와전류프로브의 T/R 코일의 와전류탐상 특성을 해석하였다. 신호해석을 위해 사용된 결함은 Notch 결함이며, 결함의 깊이는 관두께를 기준으로 40[%]로 하였으며, 결함의 위치는 관의 내부 및 외부에 있는 것으로 하였다. Transmit 코일을 중심으로 Receive 코일의 위치를 원주방향으로 $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$에 위치시키면서 신호해석을 수행하였다. 프로브의 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 이를 3차원 유한요소법을 이용하여 수치 해석을 수행하였다. 두 종류 결함의 수치해석 비교 결과 내부결함의 신호가 외부결함보다 크게 발생하였고, Transmit 코일에 대한 Receive 코일의 각도 및 위치 변화시 결함신호의 차이를 확인할 수 있었다. ASME 표준 시험편을 이용한 배열와전류 프로브의 와전류탐상 실험신호와 비교결과 유사한 신호를 확인할 수 있었다. 본 논문의 결과는 배열와전류 프로브의 와전류 탐상 신호 평가시 도움이 될 것이다.