• Title/Summary/Keyword: E-simulator

Search Result 382, Processing Time 0.017 seconds

Applicability of PAM(Polyacrylamide) in Soil Erosion Prevention: Rainfall Simulation Experiments (경사지 토양유실 방지를 위한 PAM(Polyacrylamide) 시제품의 효율성 비교평가: 실내 인공강우 실험)

  • Choi, Bong-Su;Lim, Jung-Eun;Choi, Yong-Beum;Lim, Kyoung-Jae;Choi, Joong-Dae;Joo, Jin-Ho;Yang, Jae-E.;Ok, Yong-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.3
    • /
    • pp.249-257
    • /
    • 2009
  • Surface runoff and erosion are responsible for extensive losses of top soil and agricultural productivity. In this study, a laboratory experiment was conducted to investigate the effects of different polyacrylamides (PAM) on the protection of soil from erosion and turbidity in loamy sand soil. To accomplish this, 10 and 40 kg $ha^{-1}$ of PAM were applied to the soil surface. The effects of rainfall on 10 and 20% slopes were then evaluated in the laboratory using a rainfall simulator. After air drying, the surface was subjected to rain at 30 mm $hr^{-1}$. The silt+clay of the runoff from samples treated with 10 kg PAM $ha^{-1}$ reduced by 43% and 13% when the 10% and 20% slopes were evaluated, respectively, when compared with the tap water without PAM treatment as control. The mean contents of silt+clay were reduced as the amount of PAMs applied increased at both slopes. Specifically, samples treated with 40 kg PAM $ha^{-1}$ showed reductions in the silt+clay of the runoff to 88% and 85% when the 10% and 20% slopes were evaluated, respectively, when compared to control. Furthermore, the mean turbidity of runoff in the 40 kg PAM $ha^{-1}$ treatment was reduced to 94.7% and 84.8% when the samples were subjected to 10% and 20% slopes, respectively, when compared to the control. Taken together, these findings indicate that PAM treatment will improve water pollution and agricultural productivity on sloped land via a reduction in soil erosion.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.