• 제목/요약/키워드: E-cad

검색결과 304건 처리시간 0.03초

Approximate Conversion of Rational Bézier Curves

  • Lee, Byung-Gook;Park, Yunbeom
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제2권1호
    • /
    • pp.88-93
    • /
    • 1998
  • It is frequently important to approximate a rational B$\acute{e}$zier curve by an integral, i.e., polynomial one. This need will arise when a rational B$\acute{e}$zier curve is produced in one CAD system and is to be imported into another system, which can only handle polynomial curves. The objective of this paper is to present an algorithm to approximate rational B$\acute{e}$zier curves with polynomial curves of higher degree.

  • PDF

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.

Serum allergen-specific and total IgE concentrations in dogs with allergic disorders in South Korea

  • Byoung-Gook Yoon;Han-Joon Lee;Kun-Ho Song
    • 한국동물위생학회지
    • /
    • 제46권3호
    • /
    • pp.219-225
    • /
    • 2023
  • Canine atopic dermatitis (CAD) has a genetic basis and is primarily a skin disorder characterized by allergic features. It is caused by an excessive immune response, associated with immunoglobulin E(IgE), to allergens and shows clinical signs of itching and inflammation. The present study evaluated the allergen-specific and total IgE concentration in dogs with allergic disorders. Allergen-specific IgE analysis was performed using a Multiple Allergen Simultaneous Test (MAST) assay, and total IgE analysis was conducted using an ELISA in 82 dogs with CAD. The subjects were divided into two groups: dogs aged ≤3 years and dogs aged >3 years, enabling a comparison of total IgE concentrations between the two age groups. The results showed that the major affecting environmental allergen was Alternaria alternate, and the major affecting dietary allergen was raw chestnut. The results revealed that dogs aged ≤3 years had higher total IgE concentrations than dogs aged >3 years with significant difference. The results of this study can contribute to the diagnosis and treatment of CAD in South Korea.

Cadaverine Production by Using Cross-Linked Enzyme Aggregate of Escherichia coli Lysine Decarboxylase

  • Park, Se Hyeon;Soetyono, Feilicia;Kim, Hyung Kwoun
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권2호
    • /
    • pp.289-296
    • /
    • 2017
  • Lysine decarboxylase (CadA) converts ${\small{L}}-lysine$ into cadaverine (1,5-pentanediamine), which is an important platform chemical with many industrial applications. Although there have been many efforts to produce cadaverine through the soluble CadA enzyme or Escherichia coli whole cells overexpressing the CadA enzyme, there have been few reports concerning the immobilization of the CadA enzyme. Here, we have prepared a cross-linked enzyme aggregate (CLEA) of E. coli CadA and performed bioconversion using $CadA^{CLEA}$. $CadA^{free}$ and $CadA^{CLEA}$ were characterized for their enzymatic properties. The optimum temperatures of $CadA^{free}$ and $CadA^{CLEA}$ were $60^{\circ}C$ and $55^{\circ}C$, respectively. The thermostability of $CadA^{CLEA}$ was significantly higher than that of $CadA^{free}$. The optimum pH of both enzymes was 6.0. $CadA^{free}$ could not be recovered after use, whereas $CadA^{CLEA}$ was rapidly recovered and the residual activity was 53% after the $10^{th}$ recycle. These results demonstrate that $CadA^{CLEA}$ can be used as a potential catalyst for efficient production of cadaverine.

e-Manufacturing을 위한 가상현실 기술 (Virtual Reality Technology for e-Manufacturing)

  • 조동식;손욱호
    • 전자통신동향분석
    • /
    • 제22권4호통권106호
    • /
    • pp.109-117
    • /
    • 2007
  • e-Manufacturing을 위한 가상현실 기술은 급격하게 변화하고, 시장에서의 경쟁력 확보가 절실한 제조업에서 정보기술(IT)을 접목하여 제품의 시장 출시 기간 단축 및 개발 비용의 획기적인 절감을 실현하는 것이다. 본 글에서는 e-Manufacturing의 개요, 필요성, 가상현실 기술과의 연관관계, 구성요소를 소개하고, 각 구성요소인 PLM, CAD, CAE을 가상현실 기술과 관련하여 개요 및 기술동향을 제시하고자 한다. 또한, 이를 적용한 연구 사례로 한국전자통신연구원 디지털콘텐츠연구단에서 개발한 “선박 도장 훈련 시뮬레이션”과 “설계 검증용 상용 CAD 지원 렌더링 클러스터” 기술을 소개한다.

매핑 스키마를 이용한 DXF의 STEP 파일 변환에 관한 연구 (A Study of File Transformation form DXF to STEP using Mapping Schema)

  • 김성식;정성윤;나혜숙;김인한
    • 한국전자거래학회:학술대회논문집
    • /
    • 한국전자거래학회 2000년도 종합학술대회발표논문집
    • /
    • pp.83-95
    • /
    • 2000
  • CAD 시스템간 데이터 구조 차이에 의한 교환 및 공유에 대한 문제, 동일 CAD 시스템의 버전 변화에 따른 데이터 호환성 결여, CAD 정보의 보관 및 재사용성 부족(중략)

  • PDF

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

  • Kang, Suk-Ho;Chang, Juhea;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.134-140
    • /
    • 2013
  • Objectives: There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent) and Rosetta SM (Hass), and to observe their crystalline structures. Materials and Methods: Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi) and x-ray diffraction (XRD, Rigaku) analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results: There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05). The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions: IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

효율적인 화상자료 처리와 시각 시스템과 CAD시스템의 인터페이스에 관한 연구 (A Study on Efficient Image Processing and CAD-Vision System Interface)

  • 박진우;김기동
    • 대한산업공학회지
    • /
    • 제18권2호
    • /
    • pp.11-22
    • /
    • 1992
  • Up to now, most researches on production automation have concentrated on local automation, e. g. CAD, CAM, robotics, etc. However, to achieve total automation it is required to link each local modules such as CAD, CAM into a unified and integrated system. One such missing link is between CAD and computer vision system. This thesis is an attempt to link the gap between CAD and computer vision system. In this paper, we propose algorithms that carry out edge detection, thinning and pruning from the image data of manufactured parts, which are obtained from video camera and then transmitted to computer. We also propose a feature extraction and surface determination algorithm which extract informations from the image data. The informations are compatible to IGES CAD data. In addition, we suggest a methodology to reduce search efforts for CAD data bases. The methodology is based on graph submatching algorithm in GEFG(Generalized Edge Face Graph) representation for each part.

  • PDF

Protein Analysis Using a Combination of an Online Monolithic Trypsin Immobilized Enzyme Reactor and Collisionally-Activated Dissociation/Electron Transfer Dissociation Dual Tandem Mass Spectrometry

  • Hwang, Hyo-Jin;Cho, Kun;Kim, Jin-Young;Kim, Young-Hwan;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권10호
    • /
    • pp.3233-3240
    • /
    • 2012
  • We demonstrated the combined applications of online protein digestion using trypsin immobilized enzyme reactor (IMER) and dual tandem mass spectrometry with collisionally activated dissociation (CAD) and electron transfer dissociation (ETD) for tryptic peptides eluted through the trypsin-IMER. For the trypsin-IMER, the organic and inorganic hybrid monolithic material was used. By employing the trypsin-IMER, the long digestion time could be saved with little or no sacrifice of the digestion efficiency, which was demonstrated for standard protein samples. For three model proteins (cytochrome c, carbonic anhydrase, and bovine serum albumin), the tryptic peptides digested by the IMER were analyzed using LC-MS/MS with the dual application of CAD and ETD. As previously shown by others, the dual application of CAD and ETD increased the sequence coverage in comparison with CAD application only. In particular, ETD was very useful for the analysis of highly-protontated peptide cations, e.g., ${\geq}3+$. The combination approach provided the advantages of both trypsin-IMER and CAD/ETD dual tandem mass spectrometry applications, which are rapid digestion (i.e., 10 min), good digestion efficiency, online coupling of trypsin-IMER and liquid chromatography, and high sequence coverage.