This study was conducted to determine the effects of gamma and e-beam irradiation on the quality of minced pork and pork patties. Each sample was irradiated at 5 to 20kGy, and its quality characteristics were then evaluated during storage at 30. The results of the total bacterial populations in the minced-pork and pork patty samples showed that the antimicrobial effect of gamma irradiation was superior to that of e-beam irradiation. The 2-thiobarbituric acid reactive substances (TBARS) value of all the samples significantly increased (p<0.05) as the irradiation dose and storage period increased. In addition, the gamma-irradiated (GI) samples had higher (p<0.05) TBARS values than the e-beam-irradiated (EI) samples. The volatile basic nitrogen contents of the GI samples were lower (p<0.05) than those of the EI samples. The color values, such as the $L^*$(brightness), $a^*$(redness), and $b^*$(yellowness) of the minced pork and pork patties, were increased (p<0.05) by irradiation. The hardness and sensory properties, such as the color, chewiness, taste, and overall acceptability of the pork patties, were decreased when the irradiation dose increased, and the hardness and sensory scores of the GI samples were lower than those of the EI samples.
Cho1, In-Hwan;Jo, Kyoung-Il;Choi, Jun Hyuk;Park, Hai-Woong;Kim, Chan-Joong;Jun, Byung-Hyuk
Korean Journal of Materials Research
/
v.27
no.4
/
pp.216-220
/
2017
The effect of electron beam (EB) irradiation on the electrical properties of Zn-Sn-O (ZTO) thin films fabricated using a sol-gel process was investigated. As the EB dose increased, the saturation mobility of ZTO thin film transistors (TFTs) was found to slightly decrease, and the subthreshold swing and on/off ratio degenerated. X-ray photoelectron spectroscopy analysis of the O 1s core level showed that the relative area of oxygen vacancies ($V_O$) increased from 10.35 to 12.56 % as the EB dose increased from 0 to $7.5{\times}10^{16}electrons/cm^2$. Also, spectroscopic ellipsometry analysis showed that the optical band gap varied from 3.53 to 3.96 eV with increasing EB dose. From the results of the electrical property and XPS analyses of the ZTO TFTs, it was found that the electrical characteristic of the ZTO thin films changed from semiconductor to conductor with increasing EB dose. It is thought that the electrical property change is due to the formation of defect sites like oxygen vacancies.
An, Kyung-A;Jo, Yunhee;Arshad, Muhammad Sajid;Kim, Gui-Ran;Jo, Cheorun;Kwon, Joong-Ho
Food Science of Animal Resources
/
v.37
no.2
/
pp.297-304
/
2017
Animal-origin food products pose serious threat to public food safety due to high microbial loads. The microbial and radioactive contaminations in commercial cold duck meat products were evaluated. Ten different lots of commercial samples ($C_1-C_{10}$) were classified based on type and smoking process. All samples were highly contaminated (< 4-7 Log CFU/g) with total aerobic bacteria (TAB), yeasts and molds (Y&M), and 7 samples ($C_1-C_7$) were positive for coliforms. Furthermore, three samples were contaminated with Listeria monocytogenes ($C_4-C_6$) and one with Salmonella typhimurium ($C_6$). No radionuclides ($^{131}I$, $^{137}Cs$, and $^{134}Cs$) were detected in any sample. The results of DEFT (direct epifluorescent filter technique)/APC (aerobic plate count), employed to screen pre-pasteurization treatments of products, indicated that smoked samples were positive showing DEFT/APC ratios higher than 4. Notably, the samples showed a serious threat to microbial safety, thus were irradiated with electron-beam (e-beam). The $D_{10}$ values for S. typhimurium and L. monocytogenes were 0.65 and 0.42 kGy, respectively. E-beam application at 3 and 7 kGy resulted in reduction of initial TAB, Y&M, and coliform populations by 3 and 6 log cycles, respectively. Thus, e-beam was proven to be a good decontamination approach to improve the hygiene of cold duck meat.
Kim, Ki-Joon;Park, Kang-Nam;Kim, Jo-Chun;SunWoo, Young;Son, Youn-Suk;Kim, Ki-Hyung
Journal of Korean Society for Atmospheric Environment
/
v.22
no.5
/
pp.724-730
/
2006
A study on the electron beam(E-Beam) decompositions of volatile organic compounds(VOCs) under background gases(helium, nitrogen, oxygen, air) has been carried out. Hexane selected as aliphatic VOCs was irradiated with electron beam using a batch reactor in the dose range of $0{\sim}10kGy$ and at ambient temperature. The concentrations of Hexane were 140 ppmC, 300 ppmC and 600 ppmC, respectively. Irradiation treatment efficiency of Hexane was evaluated by the GC/FID, GC/MSD, and the by-products were analyzed by $CO/CO_2\;and\;O_3$ analyzers. In different concentration, the maximum degrees of Hexane decomposition at 10 kGy were 96.4%(140 ppmC), 88.3%(300 ppmC), and 49.9%(600 ppmC). It was found that the decomposition efficiency of Hexane was higher than that of toluene at the same conditions(140 ppmC). In addition, the formation of acetone, benzene, 2-hexanone, and 3-hexanone were observed after the treatment of Hexane.
The electrical properties and defect states in ZnO substrates were studied during high-energy electron beam irradiations. 1 MeV and 2 MeV electron-beam with dose of $1{\times}10^{16}$ electrons/$cm^2$ were irradiated on Zn-surface of the sample. In the sample irradiated by 1 MeV, the leakage current was increased by electron-beam induced surface defects, while the enhancement of on/off property and the decrease of leakage current appeared in the 2 MeV irradiated sample. From the deep level transient spectroscopy measurements for these samples, it showed that the defect states with the activation energies of $E_c$-0.33 eV and $E_v$+0.8 eV are generated during the high energy electron-beam irradiation. Especially, it considered that the $E_c$-0.33 eV state related with O-vacancy affects to their electrical properties.
Aluminum nitride (AlN) thin films were prepared by using nitrogen ion beam assisted reactive radio frequency (RF) magnetron sputtering on the glass substrates without intentional substrate heating. After deposition, the effect of nitrogen ion beam energy on the structural and optical properties of AlN films were investigated by x-ray diffraction (XRD), atomic force microscope (AFM) and UV-Vis. spectrophotometer, respectively. AlN films deposited with $N^+$ ion irradiation at 100 eV show the higher (002) peak intensity in XRD pattern than other films. It means that $N^+$ ion energy of 100 eV is the favorable condition for low temperature crystallization. AFM images also show that surface average roughness is increased from 1.5 to 9.6 nm with $N^+$ ion energy in this study. In an optical observation, AlN films which deposited by $N^+$ ion beam energy of 100 eV show the higher transmittance than that of the films prepared with the other $N^+$ ion beam conditions.
The multifunctional cation exchangers, sulfonated polypropylene-g-(acrylic acid/styrene) [PP-g-(AAc/Sty)] were synthesized by the irradiational grafting of AAc and Sty onto PP staple fabric with electron beam accelerator and its subsequent sulfonation. The highest degree of grafting obtained was 190% at a monomer mixture of 30 vol% AAc: 70 vol% Sty and a solvent mixture of 30 vol% water : 70 vol% methanol and the degree of grafting decreased with an increase of the AAc content in the monomer mixture at constant solvent content. Maximum ion exchange capacity of the copolymer was 4.6 meq/g. The Li$^{+}$ adsorption ability of the copolymer synthesized in the study was the best among PP-g- AAc, sulfonated PP-g-Sty, and sulfonated PP-g-(AAc/Sty).).
Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.
Park, Jung-Jin;Choi, Hong-June;Ko, Hwan-Soon;Jeong, Eun-Hwan;Youk, Ji-Ho
Polymer(Korea)
/
v.36
no.3
/
pp.344-350
/
2012
New pressure sensitive adhesives (PSAs) for polarizer film were prepared by electron beam (e-beam) radiation to acrylic copolymers, and their adhesive properties were investigated. The acrylic copolymers were synthesized by free radical polymerization of $n$-butylacrylate (BA), 2-hydroxyethyl methacrylate (HEMA), and acrylic acid (AA). The acrylic copolymers were coated on PET release films to a thickness of 25 ${\mu}m$, laminated to polarizer films, and then radiated with e-beam at room temperature. Gel fractions of all the acrylic copolymers after e-beam radiation at 50 kGy were higher than 93%, and their crosslinking densities were increased with increasing the content of HEMA units. PSA prepared by e-beam radiation of acrylic copolymer synthesized with a feed ratio of BA/HEMA/AA = 89.5/10/0.5 (w/w/w) at a dose of 50 kGy exhibited the best adhesion performances in terms of peel strength, creep resistance, durability and reliability, and light leakage. It is expected that the preparation method of PSAs via e-beam irradiation will improve the producibility and workability of polarizer film for liquid crystal display.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.