• 제목/요약/키워드: Dynamic voltage stability

검색결과 170건 처리시간 0.027초

유도기모델을 사용한 동적 전압 안정도 해석II (DYNAMIC VOLTAGE COLLAPSE ANALYZED BY INDUCTION MOTOR MODEL II)

  • 김용배;김건중;김원겸;정태호;추진부;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.171-173
    • /
    • 1993
  • This paper deals with a methodology of the dynamic voltage stability analysis. The several physical power system constraints e.q upper and lower lomit of SVC and OLTC are considered. The proposed equivalent load model is the combination induction motor and impedance load. The variation of System voltages and equivalent induction motor slips for actual power systems are simulated and plotted in this paper.

  • PDF

부하모델을 고려한 전압 안정도 평가지표개발과 시스템 안정도 연구 (A Study on Developing Voltage Stability Index arid System Stability by Incorporating Dynamic Load Modeling)

  • 위원석;함정필;추진부;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.187-189
    • /
    • 1999
  • Accurate load models allow more precise calculations of power system stability, This paper presents new static voltage stability index considering the load models. Also, We apply the load models for the existent voltage stability indices, and evaluate them.

  • PDF

국내 계통의 단기 전압 안정도에 대한 부하 모델의 영향성 검토 및 부하 모델 파라미터 선정 (Impact of Dynamic Load Model on Short-Term Voltage Stability of Korea Power System and Estimation of Dynamic Load Model Parameters)

  • 문재민;김재경;허견;남수철;김용학
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.17-24
    • /
    • 2019
  • 본 논문은 전력계통의 부하 모델이 단기 전압 안정도 해석 결과에 미치는 영향을 분석하였다. 우선, 본 논문에서는 일반적으로 많이 사용되는 부하 모델을 소개하였고, 일부 부하 모델은 모델 파라미터를 최적화하더라도 실제 측정된 계통 현상을 재현할 수 없다는 것을 확인하였다. 또한, 본 논문에서는 상정사고 상황을 고려하여 국내 전력계통의 단기 전압 안정도 해석 시 부하 모델의 영향과 지역별 부하 모델의 영향성을 검토하였다. 해당 결과를 통해 부하 모델 선정의 중요성을 재차 확인할 수 있었으며, 상정사고 인근 지역의 부하 특성을 보다 더 정확하게 반영해야 함을 알 수 있다.

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

Luapunov 직접법에 의한 전력계통 전압안정도 해석 (A Study on Power System Voltage Stability Analysis by the Direct Lyapunov Function)

  • 문영현;박능수;이태식
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.693-702
    • /
    • 1994
  • This paper deals with direct voltage stability analysis using a power system energy function. The structure preserved energy function is proposed as an energy function for voltage stability analysis. With the use of the proposed energy function voltage collapse conditions are derived, which yields the exactly same results with the Jacobian matrix approach. The voltage collapse phenomenon is analyzed by several methods, which shows that all of the methods produce the same voltage condition. This study also investigates the voltage collapse dynamics by using the proposed energy function. As a result, it has been found that the voltage collapse can be classified into two categories: static and dynamic instablilties which have quite different behaviors. In addition a new method is presented to calculate the power capacity limit of transmission lines with respect to voltage stability. The proposed method is tested for a 2-bus sample system, which shows the characteristics of voltage collapse phenomenon via the energy function.

발전기와 부하의 동특성을 고려한 TCSC 에 의한 전압 안정화 (Voltage Stabilization by TCSC considering Dynamics of Generator and Load)

  • 조정현;손광명;이상호;박종근;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.568-570
    • /
    • 1995
  • Nowdays, voltage stability is well recognized as an important problem. It is well known that voltage stability is influenced by the characteristics of load. Up to present,voltage stability researches were done by the static load modeling, but it is needed that the precise analysis by the view point of dynamic load modeling. In this paper, with induction motor as dynamic load, using modal performance measure, optimal value of tcsc is determined.

  • PDF

동적 전압안정도 해석에서의 ULTC 및 부하모델의 적용 (Application of ULTC and load models in dynamic voltage stability analysis)

  • 송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.411-413
    • /
    • 2005
  • Static approaches usually employed in voltage stability analysis are based on the pre-determined scenarios of varying load and generation patterns. Thus, even though the approaches are applied to the same system condition, one may obtain different voltage instability phenomena using different scenarios. In the stage of concrete control strategy determination against voltage instability, dynamic approaches with full-time and/or quasi steady-state simulations need to be applied in order to confirm the effectiveness of the established control strategies. This paper describes the ULTC and dynamic load models, and discusses characteristics of the models.

  • PDF

우리나라 계통의 전압불안정 문제를 개선하기 위한 STATCOM과 SVC의 적용 검토 (A Study on the Application of STATCOM, SVC to Enhance the Voltage Stability)

  • 이상호;이정호;오태규;김태옥;문봉수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.129-131
    • /
    • 2004
  • Recent catastrophic failures of power system in various countries highlight the importance of the voltage stability and reactive power operation. Under the emergency situations, dynamic reactive power sources such as STATCOM and SVC play important roles in supporting the system voltage. This paper investigate the stability problem in KEPCO system and suggest the installation of the dynamic reactive Power sources as a countermeasure.

  • PDF

Fringe-Field Switching (FFS) 모드에서 액정의 유전율 이방성에 따른 동력학 안정성에 관한 연구 (Dynamic Stability Depending on the Dielectric Anisotropy of the LC in the Fringe-Field Switching (FFS) mode)

  • 김미숙;김향율;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제16권3호
    • /
    • pp.224-230
    • /
    • 2003
  • The voltage-dependent transmittance curve of a homogeneously aligned liquid crystal (LC) cell driven by fringe-electric field(named FFS mode) was studied, while changing dielectric anisotropy of a LC. The results show that for a LC with positive dielectric anisotropy while positioning at initial position. Therefore, we conclude that the dynamic stability is strongly dependent on the types of the LCs and voltage-dependent dynamics of the LC with negative dielectric anisotropy is staler than that of the LC with positive dielectric anisotropy in the FFS mode.

전압안정도로 제약된 계통에서 최적조류계산해가 과도안정도에 미치는 영향 (The effects of SCOPF solution to Transient Stability on Voltage Limited Power System)

  • 이근준;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.245-247
    • /
    • 2001
  • This paper presents a series of simulation results of transient stability on SCOPF operated power system whose transmission capabilities are limited by voltage stability. Three steps of voltage security guidelines, 5[%], 7[%], 10[%] are introduced to increase power transfer from generation centers to load center and observed the effects of voltage guidelines to transient stability for three kinds of load level(peak, medium, off-peak). As a result, dynamic characteristics weren't affected by the voltage security limits in model system, but became worse for the off-peak level than peak case, and sustain oscillations are observed for the all load level. This gives us some intitutions for the development and applications of security limits to use SCOPF program in open electric market.

  • PDF