• Title/Summary/Keyword: Dynamic tape

Search Result 69, Processing Time 0.034 seconds

Immediate Effects of Ankle Dorsiflexor Facilitation Dynamic Taping on Static and Dynamic Balance and Gait Speed in Stroke Patients With Foot Drop (발등굽힘근 촉진 다이나믹 테이핑이 발 처짐이 있는 뇌졸중 환자의 정적, 동적 균형과 보행 속도에 미치는 즉각적 효과)

  • Im, Jin-gu;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Foot drop is a common symptom in stroke patients. Tape applications are widely used to manage foot drop symptoms. Previous studies have evaluated the effects of static and dynamic balance and gait on foot drop using kinesiology tape; however, only few studies have used dynamic tape application in stroke patients with foot drop. Objects: The purpose of this study was to investigate the immediate effects of dynamic taping, which facilitates the dorsiflexor muscle, on static and dynamic balance and gait speed in stroke patients with foot drop. Methods: The study included 34 voluntary patients (17 men, 17 women) with stroke. The patients were randomly assigned to the experimental group (n = 17), wherein dynamic taping was used to facilitate the dorsiflexor muscle, or the control group (n = 17), wherein kinesiology taping was used. Before the taping application, velocity average, path-length average, Berg balance scale, and timed up and go test (TUG) were recorded to measure static and dynamic balance, whereas the 10-meter walk test (10MWT) was used to measure gait speed. After the taping application, these parameters were re-evaluated in both groups. Repeated measure analysis of variance was used. Statistical significance levels were set to α = 0.05. Results: Except for the 10MWT scores in the control group, significant differences were noted in all the parameters measured for static and dynamic balance and gait speed between the pre and post-test (p < 0.05). However, the parameters showed significant interaction effects between group and time in the TUG and 10MWT (p < 0.01). Conclusion: These results indicate that compared with kinesiology taping, dynamic taping used in chronic stroke patients with foot drop had a more significant effect on dynamic balance and gait speed.

The stability analysis of high-temperature superconductor tape (고온 초전도체 테이프의 안정성 해석)

  • Jeong, S.G.;Seol, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.186-191
    • /
    • 2000
  • Stability of a Bi-2223/Ag tape was studied by using a numerical method. A numerical modeling has been developed to analyze the dynamic evolution of normal zone in a composite tape Bi-2223/Ag. In this paper, the stability of HTS tape is studied by considering the non-uniform temperature distribution in a cross-sectional area. The finite-difference method(FDM) is used to solve the two-dimensional heat conduction equation. Two kinds of analyses are compared to quantify the critical disturbance energy fur quenching HTS tapes. One is the length-thickness(x-y) side and the other is the length-width(x-z) side. The results of analyses shows that the critical disturbance energies for each cases seem to be very close for considered Bi-2223/Ag tape.

  • PDF

The Influence of Magnetic Particle Size and Its Properties on The Electromagnetic Particle in Magnetic Tape (자기 Tape의 전자 변환 특성에 대한 자성분의 Size와 그 특성의 영향)

  • 김상문;김태옥
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.334-339
    • /
    • 1996
  • In order to investigate the influence of the magnetic paticle size and its properties on the particulate magnetic material, we evaluated the dispersion of magnetic particles and the electromagnetic properties in magnetic tape made from the magnetic paints by use of each magnetic particles witch were different from particle size and its propertis. The dispersion of magnetic particles depends on the surface chemical properties rather than particle size. As particle size is smaller, the packing ratio of magnetic particle and the magnetic flux density in tape increase. The output levels in playing back of tape incerase in wide frequency range from 315 Hz to 10 kHz and the noises decrease. It is very important to choose the size, the shape, the surface chemical properties and the magnetic properties of the magnetic particle in producing the high quality magnetic tape.

  • PDF

AC loss analysis and experimental evaluation of a high temperature superconductor (고온초전도선재의 교류손실 해석 및 실험)

  • Ryu, Kyung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

Transport Loss Characteristics of a Bi-2223 Tape in External AC Magnetic Fields (외부 교류지장에 대한 Bi-2223테이프의 통전손실 특성)

  • Ryu, Kyung-Woo;Kim, Chang-Wan;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.290-295
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic fields was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. A serous increase of the transport loss due to external AC magnetic field is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the external fields.

  • PDF

Analysis of normal Bone propagation characteristics in a high-temperature superconducting tape (고온 초전도체 테이프의 상전도 영역 전파 특성 해석)

  • 정신근;설승윤
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2001
  • Stability of a Bi-2223/Ag tape was studied by using a numerical model considering the temperature distribution of cross-sectional area. The dynamic evolution of normal zone of a HTS tape can be shown by the developed two-dimensional Program using finite difference method. Two kinds of analyses are compared to quantify the critical disturbance energy for quenching HTS tapes. One is the length-thickness(x-r) side and the other is the length-width(x-z) side. For each case. the governing energy balance equations and corresponding boundary conditions are formulated. The results of analyses shows that the critical disturbance energies for each cases seem to be very close for considered Bi-2223/Ag tape .

  • PDF

The Influence of External Magnetic Field on Transport Loss in a Bi-2223 tape (외부자계가 Bi-2223테이프의 통전손실에 미치는 영향)

  • 김창완;한형주;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.169-171
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic field was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. An serious increase of the transport loss due to external magnetic fields is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the applied field.

  • PDF

Design and Analysis of Loading Block of VCR Deck Mechanism (비데오 데크 메카니즘의 로딩블럭 해석 및 설계)

  • 박태원;김광배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.502-511
    • /
    • 1994
  • A video deck mechanism is composed of various cams, links, and gears, and it requires precise movement. So kinematic motion between parts should be considered to get desired movement depending on the timing chart which defines movement of each part to get desired mode. Also dynamic effects should be considered to get right tape tension and to estimate motor force required to obtain accurate motion. The design process of the deck mechanism of VCR is explained briefly. The loading block of the deck mechanism is divided into a tape translational group and a brake control group. Each group is modeled for kinematic and dynamic analysis. Finally, two groups are combined together to analyze the loading block of the deck mechanism. Results are used to understand and modify an existing design.

Effect of Acrylic Acid Contents and Inorganic Fillers on Physical Properties of Acrylic Pressure Sensitive Adhesive Tape by UV Curing (아크릴산 함량 및 무기물 충전제가 UV 경화형 아크릴 점착테이프의 물성에 미치는 영향)

  • Kim, Dong-Bok
    • Polymer(Korea)
    • /
    • v.37 no.2
    • /
    • pp.184-195
    • /
    • 2013
  • Acrylic pressure sensitive adhesive (PSA) tapes were used for the automotive, the electrical and the electronic industries and the display module junction. In this study, the manufacture of high-strength structural tape used 2-ethylhexyl acrylate (2-EHA) and acrylic acid (AAC), and UV irradiation for photo-polymerization, and the semi-structural properties of acrylic PSA tape with the AAC content and inorganic filler $SiO_2$ content were investigated. The initial adhesion strength was lowered by the rigidity of molecule chains due to the use of AAC, and the adhesion strength increased with increasing wetting time. The wetability, contact angle, and SEM images of PSA tapes with various contents of AAC were determined. Without filler, the peel strength and dynamic shear strength of PSA tape showed inverse correlation but the peel strength and dynamic shear strength increased with increasing filler content. From these correlations the PSA tapes could be optimized for the applications requiring high performance.