• 제목/요약/키워드: Dynamic resolution

검색결과 549건 처리시간 0.032초

High-Resolution Interrogation Technique for Fiber Bragg crating Sensor Using Long-Period Fiber Grating Pair and Erbium-Doped fiber

  • Jung, Jae-Hoon;Lee, Yong-Wook;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제6권1호
    • /
    • pp.5-12
    • /
    • 2002
  • A novel interrogation scheme to detect fine Bragg wavelength shift using a long period fiber grating pair with erbium-doped fiber inserted between the two gratings is reported. The technique is shown to feature high resolution and much more immunity to temperature perturbation compared to the conventioned Mach-Zehnder interferometer demodulation system. For quasi-static strain measurement, this approach provides high wavelength resolution of 0.05 pm that corresponds to 41.7 ne in strain and $3.8 $\times$ 10^{-3}$$^{\circ}C$ in temperature. This interrogation system is also employed in dynamic measurement to obtain the minimum detectable strain perturbation of ~ 8.76 ne/H $z^{{\frac}{1}{2}}$ at 100 Hz. Moreover, this interrogation system has prominent thermal stability. This thermal stability comes from the fact that two arms of the interferometer, the core and cladding in erbium-doped fiber, are exposed to nearly the same environment .

동부호화 최적화 기법의 성능개선을 위한 과거 검색정보의 활용 (Improvement of Dynamic encoding algorithm with history information)

  • 박영수;김종욱;김연탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.111-113
    • /
    • 2006
  • DEAS is an direct searching and optimization method that based on the binary code space. It can be classified as an direct hill climbing searching. However, because of binary code space based searching, the searching in low resolution has random property. As the resolution of code increases during the search, its property of searching changes like that of hill climbing search. This paper propose a method for improving the performance of minimum seeking ability of DEAS with history information. The cost evaluation is increased. However the minimum searching ability of DEAS is improved along the same starting resolution.

  • PDF

초음파 B스캔너의 개발(I) -시스템 및 아나로그부분- (Development of Ultrasound B-scanner(I)-System and Analog Part-)

  • 김진하;신동희
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF

유한요소법을 이용한 Super-ROM 디스크 구조의 열 분포 해석 (Simulations of time dependent temperature distributions of Super-ROM disk structure using finite element method)

  • 안덕원;유천열
    • 정보저장시스템학회논문집
    • /
    • 제1권2호
    • /
    • pp.132-136
    • /
    • 2005
  • It is widely accepted that the reading mechanism of Super-RENS(super-resolution near field structure) and Super-ROM(super-resolution read only memory) is closely related with non-linear temperature dependent material properties such as refractive indices, phase change. Furthermore, the dynamic change of the temperature distribution also an essential part of reading mechanism of Super-RENS/ROM. Therefore, the knowledge of the temperature distribution as a function a time is one of the important keys to reveal the physics of reading mechanism in Super-RENS/ROM. We calculated time-dependent temperature distribution in a 3-dimensional Super-ROM disk structure when moving laser beam is irradiated. With a help of commercial software FEMLAB which employed finite element method, we simulated the temperature distribution of ROM structure whose pit diameter is 120-nm with 50-nm depth. Energy absorption by moving laser irradiation, time variations of heat transfer processes, heat fluxes, heat transfer ratios, and temperature distributions of the complicate 3-dimensional ROM structure have been obtained.

  • PDF

저분해능 위치센서를 갖는 표면부착형 영구자석 동기전동기의 전류센서 없는 단위 전류 당 최대 토크 제어 (Current-Sensorless Maximum Torque per Ampere Control for a Surface Mounted Permanent Magnet Synchronous Motor with Low-Resolution Position Sensor)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.204-210
    • /
    • 2009
  • 본 논문에서는 저분해능 위치센서를 갖는 표면부착형 영구자석 동기전동기의 새로운 전류센서 없는 단위 전류당 최대 토크 제어를 제안한다. 영구자석 동기전동기의 수학적 모델로부터 d축 전류를 추정하고, 추정된 d축 전류가 영(零)이 되도록 d축과 q축 전압지령 사이의 위상 각을 제어하여 단위 전류 당 최대 토크 제어를 구현한다. 제안된 방식은 동적 응답 특성이 느린 저가 응용 분야에 적합하다.

회귀방법에 의한 초음파 진단기의 측면해상도 개선에 관한 연구 (A recursive scheme for improvement of the lateral resolution in B-scan ultrasonography)

  • 김선일;민병구;고명삼
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.204-208
    • /
    • 1982
  • The objective of this paper is to present a digital method for improving the lateral resolution of the B-scan images in the medical applications of ultrasound. The method is based upon a mathematical model of the lateral blurring caused by the finite beam width of the transducers. This model provides a simple method of applying a recursive scheme for image restoration with fast computation time. The point spread function (P.S.F.) can be measured by the reflective signals after scanning the small pins located along the depth of interest. From the measured P.S.F., one can compute the coefficient matrices of the inverse discrete-time dynamic state variable equation of the blurring process. Then, a recursive scheme for deblurring is applied to the recorded B-scan to improve the lateral resolution. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

An Efficient Focusing Method for High Resolution Ultrasound Imaging

  • Kim Kang-Sik
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권1호
    • /
    • pp.22-29
    • /
    • 2006
  • This paper proposes an efficient array beamforming method using spatial matched filtering for ultrasound imaging. In the proposed method, ultrasound waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency (RF) echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed. The filter remaps and spatially registers the acoustic energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that the proposed spatial filtering method can provide more improved spatial resolution and contrast-to-noise ratio (CNR) compared with conventional dynamic receive focusing (DRF) method by implementing two-way dynamically focused beam pattern throughout the field.

HSFE Network and Fusion Model based Dynamic Hand Gesture Recognition

  • Tai, Do Nhu;Na, In Seop;Kim, Soo Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권9호
    • /
    • pp.3924-3940
    • /
    • 2020
  • Dynamic hand gesture recognition(d-HGR) plays an important role in human-computer interaction(HCI) system. With the growth of hand-pose estimation as well as 3D depth sensors, depth, and the hand-skeleton dataset is proposed to bring much research in depth and 3D hand skeleton approaches. However, it is still a challenging problem due to the low resolution, higher complexity, and self-occlusion. In this paper, we propose a hand-shape feature extraction(HSFE) network to produce robust hand-shapes. We build a hand-shape model, and hand-skeleton based on LSTM to exploit the temporal information from hand-shape and motion changes. Fusion between two models brings the best accuracy in dynamic hand gesture (DHG) dataset.

선형 모터의 동특성 분석 (Analysis of the Dynamic Characteristics of the Linear Motors)

  • 설진수;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.258-263
    • /
    • 2005
  • The nearest variety of the industrial world requires using the high precision and resolution positioning technology to do a semi-conductor, information field , and measurement field. It is especially important for the positioning technology that makes up a proper controller, is affected by the minimal heat and vibration, and can control a structurally generated non-linear friction factor to determine the efficiency of the system. The paper is to analyze the vibration characteristic according to the speed of linear motor and grasp the dynamic characteristic through the modal test and show the verification of the experimental result and design parameters by using FEM(Finite Element Method). Also, it shows the optimum standard analyzed the acceleration patterns of the moving part that lead to the vibration source in linear motor. It presents the analyzed dynamic of linear motor in compliance with a change of the non-linear factor.

  • PDF

넓은 다이내믹 레인지의 유연 촉각센서 적용을 위한 PVP 유전층과 PDMS 접착력 검증 (Verification of Bonding Force between PVP Dielectric Layer and PDMS for Application of Flexible Capacitive-type Touch Sensor with Large Dynamic Range)

  • 원동준;허명;김준원
    • 로봇학회논문지
    • /
    • 제11권3호
    • /
    • pp.140-145
    • /
    • 2016
  • In this paper, we fabricate arrayed-type flexible capacitive touch sensor using liquid metal (LM) droplets (4 mm spatial resolution). Poly-4-vinylphenol (PVP) layer is used as a dielectric layer on the electrode patterned Polyethylene naphthalate (PEN) film. Bonding tests between hydroxyl group (-OH) on the PVP film and polydimethylsiloxane (PDMS) are conducted in a various $O_2$ plasma treatment conditions. Through the tests, we can confirm that non-$O_2$ plasma treated PVP layer and $O_2$ plasma treated PDMS can make a chemical bond. To measure dynamic range of the device, one-cell experiments are conducted and we confirmed that the fabricated device has a large dynamic range (~60 pF).