• Title/Summary/Keyword: Dynamic range extension

Search Result 50, Processing Time 0.023 seconds

Extension of the Dynamic Range in the CMOS Active Pixel Sensor Using a Stacked Photodiode and Feedback Structure

  • Jo, Sung-Hyun;Lee, Hee Ho;Bae, Myunghan;Lee, Minho;Kim, Ju-Yeong;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.256-261
    • /
    • 2013
  • This paper presents an extension of the dynamic range in a complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) using a stacked photodiode and feedback structure. The proposed APS is composed of two additional MOSFETs and stacked P+/N-well/P-sub photodiodes as compared with a conventional APS. Using the proposed technique, the sensor can improve the spectral response and dynamic range. The spectral response is improved using an additional stacked P+/N-well photodiode, and the dynamic range is increased using the feedback structure. Although the size of the pixel is slightly larger than that of a conventional three-transistor APS, control of the dynamic range is much easier than that of the conventional methods using the feedback structure. The simulation and measurement results for the proposed APS demonstrate a wide dynamic range feature. The maximum dynamic range of the proposed sensor is greater than 103 dB. The designed circuit is fabricated by the $0.35-{\mu}m$ 2-poly 4-metal standard CMOS process, and its characteristics are evaluated.

Operation of a wide dynamic range CMOS image sensor based on dual sampling mechanism and its SPICE simulation (이중 샘플링 기반의 넓은 동작 범위 CMOS 이미지 센서의 동작 및 시뮬레이션을 통한 특성 분석)

  • Kong, Jae-Sung;Jo, Sung-Hyun;Lee, Soo-Yeun;Choi, Kyung-Hwa;Seo, Sang-Ho;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2010
  • In this paper, a dynamic range(DR) extension technique based on a 3-transistor active pixel sensor(APS) and dual image sampling is proposed. The feature of the proposed APS is that the APS uses two or more photodiodes with different sensitivities, such as a high-sensitivity photodiode and a low-sensitivity photodiode. Compared with previously proposed wide DR(WDR) APS, the proposed approach has several advantages, such as no-external equipments or signal processing, no-additional time-requirement for additional charge accumulation, simple operation and adjustable DR extension by controlling parasitic capacitance and sensitivity of two photodiodes. Approximately 16 dB of DR extension was evaluated from the simulation for the situation of 10 times of sensitivity difference and the same size of parasitic capacitance between those two photodiodes.

Effect of Lumbar Stabilizing Exercise SEBT Training on Isometric Lumbar Strength, Dynamic Balance Ability and Range of Motion in Open Laser Lumbar Microdisectomy Patients (미세 현미경 레이저 요추 디스크 절제술 환자의 요부안정화운동과 SEBT 트레이닝이 등척성 요부근력과 동적균형능력, 관절가동범위에 미치는 영향)

  • Jeon, Ho-Min;Kim, Jung-Hoon;Lee, Jang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.212-220
    • /
    • 2020
  • This study examines the effects on isometric lumbar extension strength, dynamic balance ability, and range of motion, after administering 8 weeks SEBT exercise (dynamic balance exercise) and Lumbar Stabilizing exercise, to open laser lumbar microdiscectomy patients. Totally, 14 patients who underwent preservation treatment for 6 weeks after undergoing open laser lumbar microdiscectomy, were enrolled for the study. Patients were randomly assigned to the Lumbar Stabilizing Exercise Group (LSG, n=7) and SEBT Exercise + Lumbar Stabilizing Exercise Group (SGLS, n=7). Results indicate that isometric lumbar extension strength ratio significantly decreases after 8 weeks rehabilitation exercise in both the LSG (p=0.007) as well as SLSG (p=0.024) groups. Normalized reach distance of the three directions in the Y-balance test to examine the dynamic balance capability showed a significant increase in both groups. The dynamic balance capability showed significant increase to the left (LSG, p=0.010; SLSG, p=0.002) and right (LSG, p=0.002; SLSG, p=0.002). Moreover, significant increase was also obtained in the range of joint operation, in both LSG (p=0.006) and SLSG (p=0.017) groups. These results indicate that both groups of rehabilitation exercise achieve positive outcomes on the isometric lumbar extension strength, range of motion, and dynamic balance ability. However, some results suggest that the SEBT program is likely to have a better efficacy.

Inter-rater Reliability of Cervical Proprioception, Dynamic Balance and Dorsiflexion Range of Motion Ising STARmat®

  • Park, Ji-Won;Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.88-93
    • /
    • 2020
  • Purpose: This study examined the inter-rater reliability of cervical proprioception, dynamic balance ability, and ankle dorsiflexion range of motion using STARmat®, which is a practical clinical tool that can provide practitioners and patients with quantitative and qualitative results. Methods: Thirty healthy young subjects were enrolled in this study, and two well-trained physical therapists participated as a tester. Two testers measured the cervical joint position error at the starting position after neck flexion, extension, side bending, and rotation; three dynamic balance tests, including anterior excursion, anterior reaching with single leg balance, and posterior diagonal excursion; and ankle dorsiflexion range of motion using STARmat®. The intra-class correlation coefficient (ICC) was used to determine the inter-rater reliability of the tests. Results: The inter-rater reliability for the cervical proprioception ranged from moderate to good (0.66 to 0.83), particularly for flexion (0.82), extension (0.70), right side bending (0.73), left side bending (0.71), right rotation (0.83), and left rotation (0.66). For the dynamic balance, the inter-rater reliability ranged from good to excellent (0.87 to 0.91), particularly for anterior excursion (0.86), posterior diagonal excursion (0.87 to 0.89), and anterior reaching with a single leg balance (0.90 to 0.91). In addition, for the ankle dorsiflexion range of motion, the ICC for the inter-rater reliability ranged from 0.95 to 0.96. Conclusion: STARmat® is a reliable tool for measuring cervical proprioception, dynamic balance tests, and ankle dorsiflexion range of motion in healthy young adults.

Extension of the Dynamic Range using the Switching Operation of In-Pixel Inverter in Complementary Metal Oxide Semiconductor Image Sensors

  • Seong, Donghyun;Choi, Byoung-Soo;Kim, Sang-Hwan;Lee, Jimin;Lee, Jewon;Lee, Junwoo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.71-75
    • /
    • 2019
  • This paper proposes the extension of the dynamic range in complementary metal oxide semiconductor (CMOS) image sensors (CIS) using switching operation of in-pixel inverter. A CMOS inverter is integrated in each unit pixel of the proposed CIS for switching operations. The n+/p-substrate photodiode junction capacitances are added to each unit pixel. When the output voltage of the photodiode is less than half of the power supply voltage of the CMOS inverter, the output voltage of the CMOS inverter changes from 0 V to the power supply voltage. Hence, the output voltage of the CMOS inverter is adjusted by changing the supply voltage of the CMOS inverter. Thus, the switching point is adjusted according to light intensity when the supply voltage of the CMOS inverter changes. Switching operations are then performed because the CMOS inverter is integrated with in each unit pixel. The proposed CIS is composed of a pixel array, multiplexers, shift registers, and biasing circuits. The size of the proposed pixel is $10{\mu}m{\times}10{\mu}m$. The number of pixels is $150(H){\times}220(V)$. The proposed CIS was fabricated using a $0.18{\mu}m$ 1-poly 6-metal CMOS standard process and its characteristics were experimentally analyzed.

Effect of Game-Based Balance Training with CIMT on Pain, Muscle Strength, Range of Motion and Dynamic Balance in Female Patients with Total Knee Replacement

  • Lee, Hyo Bin;Choi, Ho Suk;Shin, Won Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.159-165
    • /
    • 2018
  • Purpose: The aims of this study were to determine if game-based training with constraint-induced movement therapy (CIMT) is effective in improving the balance ability in female patients with a total knee replacement, and to provide clinical knowledge of CIMT game-based training that allows the application of total knee replacement. Methods: Thirty-six patients who had undergone a total knee replacement were assigned randomly to CIMT game training (n=12), general game training (n=12), and self-exercise (n=12) groups. All interventions were conducted 3 times a week for 4 weeks. All patients used a continuous passive motion machine 5 times a week and 2 times a day for 4 weeks. The visual analog scale (VAS), muscle strength of knee flexion and extension, and range of motion (ROM) of knee flexion and extension were assessed, and the functional reach test (FRT), and timed up and go (TUG) test were performed to evaluate the balance ability. Results: All 3 groups showed significant improvement in the VAS, knee flexion and extension muscle strength, FRT, and TUG test after the intervention (p<0.05). Post hoc analysis revealed significant differences in FRT, and TUG of the CIMT game training group compared to the other group (p<0.05). Conclusion: Although the general game training and CIMT game training improved both the knee extension muscle strength and dynamic balance ability, CIMT game training had a larger effect on dynamic balance control.

Comparison of the Duration of Hamstring Flexibility Improvement Following Termination of Modified Dynamic Stretching, Hold-Relax, and Static Stretching

  • Moon, A-Young;Jang, Hee-Jin;Jang, Hyun-Jeong;Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • The aim of this study was to compare the duration of hamstring flexibility improvement after 3 stretching interventions in people with limited hamstring flexibility. Twenty-two subjects (12 men, 10 women) with limited hamstring flexibility of the dominant leg received 3 stretching interventions- modified dynamic stretching (MDS), hold-relax (HR), and static stretching (SS)-in a random order. All the subjects received all 3 interventions at intervals of at least 24 hours to minimize any carry-over effect. Modified dynamic stretching was applied as a closed kinetic chain exercise in the supine position by using the sling suspension system (Redcord Trainer(R)). The SS and HR interventions were individually performed in the straight leg raising (SLR) position, and all 3 interventions were performed for 3 minutes. Outcome measures included passive knee extension (PKE) measurements. Five post-test measurements were recorded for all subjects at 3, 6, 9, 15, and 30 minutes after the interventions. MDS was associated with a significant increase in knee extension range of motion even at 30 minutes post-treatment. In contrast, the HR and SS stretching methods showed increased hamstring flexibility for only 6 minutes post-treatment. Improvements in the range of motion of knee extension (indicating enhancement in hamstring flexibility) with MDS were maintained longer than those with the HR and SS interventions. Therefore, MDS may be more effective than the other interventions for maintaining hamstring flexibility.

A Wide Dynamic Range CMOS Image Sensor Based on a Pseudo 3-Transistor Active Pixel Sensor Using Feedback Structure

  • Bae, Myunghan;Jo, Sung-Hyun;Lee, Minho;Kim, Ju-Yeong;Choi, Jinhyeon;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.413-419
    • /
    • 2012
  • A dynamic range extension technique is proposed based on a 3-transistor active pixel sensor (APS) with gate/body-tied p-channel metal oxide semiconductor field effect transistor (PMOSFET)-type photodetector using a feedback structure. The new APS consists of a pseudo 3-transistor APS and an additional gate/body-tied PMOSFET-type photodetector, and to extend the dynamic range, an NMOSFET switch is proposed. An additional detector and an NMOSFET switch are integrated into the APS to provide negative feedback. The proposed APS and pseudo 3-transistor APS were designed and fabricated using a $0.35-{\mu}m$ 2-poly 4-metal standard complementary metal oxide semiconductor (CMOS) process. Afterwards, their optical responses were measured and characterized. Although the proposed pixel size increased in comparison with the pseudo 3-transistor APS, the proposed pixel had a significantly extended dynamic range of 98 dB compared to a pseudo 3-transistor APS, which had a dynamic range of 28 dB. We present a proposed pixel that can be switched between two operating modes depending on the transfer gate voltage. The proposed pixel can be switched between two operating modes depending on the transfer gate voltage: normal mode and WDR mode. We also present an imaging system using the proposed APS.

Long-term Variations of Chemical Properties in Controlled Horticultural Soils of Gyeongnam Province

  • Lee, Young-Han;Lee, Seong-Tae;Hong, Kang-Pyo;Lee, Sang-Dae;Kim, Je-Hong;Ok, Yong-Sik;Kim, Min-Keun;Kim, HyeRan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.5
    • /
    • pp.308-312
    • /
    • 2013
  • The monitoring of chemical dynamic changes in controlled horticultural lands is very important for agricultural sustainability. Field monitoring was performed to evaluate the soil chemical properties of 200 controlled horticultural soil samples in Gyeongnam province every 4 years from 2000 to 2012. Soil chemical properties such as pH, amount of organic matter, available phosphate, nitrate nitrogen, and exchangeable potassium, calcium, magnesium, and sodium were analyzed. The amount of exchangeable calcium and soil pH were significantly higher in 2012 than in 2000. In 2012, the frequency distribution for values of pH, organic matter, available phosphate, and exchangeable potassium, calcium, and magnesium that were within the optimum range was 16.0%, 22.5%, 11.5%, 3.5%, 2.5%, and 5.0%, respectively. Especially, available phosphate and exchangeable calcium were excess level with portions of 76.0% and 96.5%, respectively. These results indicated that a balanced management of soil chemical properties can reduce the amount of fertilizer applied for sustainable agriculture in controlled horticultural lands.

Analysis of Metal Transfer using Dynamic Force Balance Model in GMAW (동적 힘 평형 모델을 이용한 GMA 용접의 용적이행 해석)

  • 최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.399-405
    • /
    • 2001
  • A dynamic force balance model is proposed in this work as an extension of the previous static force balance model to predict metal transfer in arc welding. Dynamics of a pendant drop is modeled as the second order system, which consists of the mass, spring and damper. The spring constant of a spherical drop at equilibrium is derived in the closed-form equation, and the inertia force caused by drop vibration is included in the drop detaching condition. While the inertia force is small in the low current range, it becomes larger than the gravitational force with current increase. The inertia force reaches half of the electromagnetic force at transition current, and has considerable effects on drop detachment. The proposed dynamic force balance model predicts the detaching drop size more accurately than the static force balance model.

  • PDF