• 제목/요약/키워드: Dynamic power cable

검색결과 59건 처리시간 0.02초

동적 파워 케이블의 해양운용환경 내구성 검증시험에 관한 연구 (A Study for Durability Test of Dynamic Power Cable under Marine Operating Environment Condition)

  • 심천식;김철민;노유호;이재복;채광수;송하철;김호경;배철민;위성국;임기천
    • 대한조선학회논문집
    • /
    • 제58권1호
    • /
    • pp.49-57
    • /
    • 2021
  • In the production power transmitting of a floating production system like a wind offshore floating, the power cable should be connected from the surface system into the subsea system. The connection between the surface and the subsea system will make the power cable get a dynamic load like current and wave forces. Based on this condition, a dynamic power cable is required to endure external physical force and vibration in the long-term condition. It needs more requirements than static power cable for mechanical fatigue properties to prevent failures during operations in marine environments where the external and internal loads work continuously. As a process to verify, the durability test of dynamic power cables under the marine operation environment condition was carried out by using domestic technology development.

강한 전단 해류 환경에서 동적 전력케이블의 VIV 피로해석 절차에 관한 기초 연구 (A Fundamental Study of VIV Fatigue Analysis Procedure for Dynamic Power Cables Subjected to Severely Sheared Currents)

  • 심천식;김민석;김철민;노유호;이재복;채광수;김강호;정다슬
    • 대한조선학회논문집
    • /
    • 제60권5호
    • /
    • pp.375-387
    • /
    • 2023
  • The subsea power cables are increasingly important for harvesting renewable energies as we develop offshore wind farms located at a long distance from shore. Particularly, the continuous flexural motion of inter-array dynamic power cable of floating offshore wind turbine causes tremendous fatigue damages on the cable. As the subsea power cable consists of the helical structures with various components unlike a mooring line and a steel pipe riser, the fatigue analysis of the cables should be performed using special procedures that consider stick/slip phenomenon. This phenomenon occurs between inner helically wound components when they are tensioned or compressed by environmental loads and the floater motions. In particular, Vortex-induced vibration (VIV) can be generated by currents and have significant impacts on the fatigue life of the cable. In this study, the procedure for VIV fatigue analysis of the dynamic power cable has been established. Additionally, the respective roles of programs employed and required inputs and outputs are explained in detail. Demonstrations of case studies are provided under severely sheared currents to investigate the influences on amplitude variations of dynamic power cables caused by the excitation of high mode numbers. Finally, sensitivity studies have been performed to compare dynamic cable design parameters, specifically, structural damping ratio, higher order harmonics, and lift coefficients tables. In the future, one of the fundamental assumptions to assess the VIV response will be examined in detail, namely a narrow-banded Gaussian process derived from the VIV amplitudes. Although this approach is consistent with current industry standards, the level of consistency and the potential errors between the Gaussian process and the fatigue damage generated from deterministic time-domain results are to be confirmed to verify VIV fatigue analysis procedure for slender marine structures.

불평형 고장시의 초전도 케이블의 응동 특성 (Dynamic Characteristic of the Superconducting Cable in unbalanced Faults)

  • 이근준;이종배;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.37-39
    • /
    • 2007
  • In the faults of power line, single line ground and line-to-line fault make power system to unbalanced. These fault currents make unbalanced power system. This paper suggests the simulation results of dynamic characteristic of HTS cable system under unbalanced faults condition using EMTDC, Quench phenomenon and current limiting effects are observed. However, quench on the HTS is destroy cable system, coordination with SFCL has to be considered.

  • PDF

케이블 장력 및 피뢰기의 강성 변화를 고려한 애자형 피뢰기의 동특성 시험 연구 (Experimental Study on the Dynamic Characteristics of Porcelain Surge Arrestor Considering the Variation of Cable's Tension and Arrestor's Stiffness)

  • 장정범;황경민;연관희
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.253-259
    • /
    • 2014
  • Porcelain surge arrestor is very vulnerable to earthquake but there is very few information on its dynamic characteristics which are necessary to the seismic design. Therefore, the dynamic characteristics of the porcelain surge arrestor are evaluated considering the variation of its cable tension and stiffness by shaking table test. The test results show that the first natural frequencies are 5.3 Hz and 5.2 Hz in the horizontal x- and y-axis directions, respectively, and higher than 30 Hz in the vertical z-axis direction, respectively. The installation of cable on the surge arrestor reduces the horizontal natural frequencies due to the constraint effect of the cable but cable tension has no effect on the natural frequency. Also, the natural frequency is proportional to the stiffness of the surge arrestor. This test result will be used for the seismic design and seismic capacity assessment of domestic substations and contribute to the stability of the electric power supply under earthquake event.

초전도 전력케이블의 열 등가 회로에 관한 연구 (A Study on the Equivalent Thermal Circuit for HTS Power Cable)

  • 이수길;이흥재
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.61-65
    • /
    • 2010
  • To develop the thermal analysis method for the thermal behavior of HTS power cable system, cooled with sub-cooled liquid nitrogen, new thermo dynamic model for HTS cable system is introduced. The introduced thermal model is mainly modified from the thermal circuit following to IEC60287 for underground power cable systems such as XLPE or paper wrapped insulation cables. The thermal circuits for HTS cables are similar to the forced cooled underground cable system but the major thermal parameters and the configuration is apparently different to the normal cable systems so there has been no proposals in this field of analysing method. In this paper, 154kV HTS cable system has been introduced as an aspects of thermal models and a thermal circuit is proposed for the fundamentals on the dynamic rating systems for the HTS cable system. By using the thermal circuit developed in this paper, the optimal controls on the sub-cooling system's capacity become possible and it is expected to make the efficiency of HTS cable higher than conventional static controls.

지중송전선로 실시간 송전용량 산정 시스템 개발(I) - 실시간 도체온도 산정 시스템 (The Dynamic Rating System(I) - Real Time Conductor Temperature Monitoring System)

  • 남석현;이충환;이수길;백주흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1455-1457
    • /
    • 2002
  • The real-time dynamic rating system(DRS) can provide the maximum ampacity within required periods, so it can help the transmission-line operation more safely and efficiently. Because the conductor temperature is the main limit of increasing rating current, conductor temperature monitoring(CTM) technology is the basic to DRS. In this paper, real-time CTM was developed for 345kV XLPE cable in tunnel and we have also compared the CTM result of this study with the result according to IEC 287 and JCS 168 thermal parameters.

  • PDF

전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템 (A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring))

  • 남석현;이수길;홍진영;김정년;정성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.

대규모 계통의 동적 축약에 관한 연구 (A Study on the Dynamic Reduction of Large-Scale Power Systems)

  • 김형준;장길수;윤용범;이진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.399-404
    • /
    • 2000
  • This paper presents new algorithms equivalencing large-scale power systems. Generators are identified to the coherent groups according to the relation factors, which represent the relative coupling degree between the generators. While the groups are identified, participation numbers, which are the measure of the relative participation of the generators in the group, are obtained. All generators and controllers in the group are weighted by participation numbers and aggregated to construct a dynamic equivalent. The proposed algorithms are applied to a 272-machine Korea Electric Power Corporation (KEPCO)'s system. The enclosed results indicate the accuracy and usefulness of the algorithms.

  • PDF

동적 물성치를 고려한 진공 인터럽터 충격특성의 영향인자 분석 (Parameter Study of Impact Characteristics for a Vacuum Interrupter Considering Dynamic Material Properties)

  • 임지호;송정한;허훈;박우진;오일성;안길영;최종웅
    • 대한기계학회논문집A
    • /
    • 제26권5호
    • /
    • pp.924-931
    • /
    • 2002
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

동적 계획 알고리즘을 이용한 효과적인 케이블 드럼 스케줄 및 자동화 프로그램 구현 (Implementation of Automation Program and Efficient Cable Drum Schedule using Dynamic Programming Algorithm)

  • 박기홍;이양선
    • 디지털콘텐츠학회 논문지
    • /
    • 제17권4호
    • /
    • pp.257-263
    • /
    • 2016
  • 케이블 드럼 스케줄은 발전소 전기설비 설계를 위한 최종단계로 레이스웨이에 포설 계획된 케이블들을 효율적으로 케이블 드럼에 할당하는 것이다. 본 논문에서는 케이블들을 코드별로 케이블 드럼 용량에 맞게 스케줄링 하는 자동화 프로그램을 구현하였으며, 케이블 드럼 스케줄을 위한 최적화 문제를 효과적으로 해결하기 위해 동적 계획 알고리즘을 적용하였다. 구현 결과 케이블 드럼 스케줄 자동화는 설계 규격대로 수행됨을 확인할 수 있었고, 기존방법에서 발생되는 케이블 부족 및 낭비와 같은 오류를 제거 및 케이블 드럼 스케줄 소요시간을 줄일 수 있었다. 발전소 전기설비를 위한 케이블은 최소 2만개 이상으로 설계되기 때문에 제안하는 자동화 프로그램을 적용한다면 심각한 오류 없이 케이블 드럼 스케줄의 설계 소요시간을 현저히 줄일 수 있을 것으로 사료된다.