• Title/Summary/Keyword: Dynamic lens

Search Result 81, Processing Time 0.029 seconds

Design of the Hybrid Optical Pickup Actuator by Numerical Simulation of Heat Transfer (열전달 수치해석에 의한 하이브리드 광픽업 액추에이터의 설계)

  • Shin, Su-Ho;Lee, Jin-Won;Cheong, Young-Min;Kim, Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.798-800
    • /
    • 2003
  • Recently, in optical storage device technical trends, the size of optical drive is slimmer to adopt notebook computer and the power of actuator is higher to achieve the high transfer rate. However, these trends of optical disc drives tend to increase the temperature of the actuator part, it causes some problems on the performance of optical parts - the resonance frequency of the actuator is down to lower band and the objective lens, coil and magnet are easily damaged. In this study, to overcome these thermal problems, the numerical simulations of heat transfer were performed. As the result of simulations, the thermal characteristic of the hybrid actuator is better than the previous design. And, it shows the good dynamic performance in experiment.

  • PDF

Development of A Small VCM Focusing Actuator (초소형 VCM 포커싱 액츄에이터 개발)

  • Shin, Young-Chul;Lee, Seung-Yop;Park, Young-Phil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.750-755
    • /
    • 2005
  • This paper proposes a small VCM (Voice coil motor) type actuator using curved suspensions for auto-focusing and zoom motions for mobile information devices. 1'he proposed focusing actuator adopts a nontraditional type of suspension using curved beams in order to extend output displacement within small height restriction. The curved beam is similar to the leaf spring type which is usually used in optical disk drives. In addition, three different materials are considered for the curved suspension model, and Aluminum shows the best dynamic characteristics. The proposed zoom actuator does not use a suspension supporting bobbin but a moving rail and a sloper mechanism by generating rotational force at lens holder. The sensitivity of design parameters on output performance is studied using ANSYS (3D FEM tool). Experiments using a prototype of the proposed actuator model verified the analytical prediction and performance.

  • PDF

Camera calibration parameters estimation using perspective variation ratio of grid type line widths (격자형 선폭들의 투영변화비를 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Choi, Seong-Gu;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.30-32
    • /
    • 2004
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as lens distortion, focal length, scale factor, pose, orientations, and distance. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1, 2, 3, 4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. The average scale factor tends to fluctuate with small variation and makes distance error decrease. Compared with classical methods that use stereo camera or two or three orthogonal planes, the proposed method is easy to use and flexible. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

Preliminary study on car detection and tracking method using surveillance camera in tunnel environment for accident detection (터널 내 유고상황 자동 판정을 위한 선행 연구: CCTV를 이용한 차량의 탐지와 추적 기법 고찰)

  • Oh, Young-Sup;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.813-827
    • /
    • 2017
  • Surveillance cameras installed in tunnels capture the various video frames effected by dynamic and variable factors. In addition, localizing and managing the cameras in tunnel is not affordable, and quality of capturing frame is effected by time. In this paper, we introduce a new method to detect and track the vehicles in tunnel by using surveillance cameras installed in a tunnel. It is difficult to detect the video frames directly from surveillance cameras due to the motion blur effect and blurring effect on lens by dirt. In order to overcome this difficulties, two new methods such as Differential Frame/Non-Maxima Suppression (DFNMS) and Haar Cascade Detector to track cars are proposed and investigated for their feasibilities. In the study, it was shown that high precision and recall values could be achieved by the two methods, which then be capable of providing practical data and key information to an automatic accident detection system in tunnels.

Aspheric Lens Measurements by Digital Holographic Microscopy and Liquid (액체와 Digital Holographic Microscopy을 이용한 비구면 렌즈 측정 연구)

  • Kim, Doocheol;Shin, Sanghoon;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.318-323
    • /
    • 2013
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on both the refractive index and the morphology of the sample. When interference fringes are very closely spaced, the phase data contain high frequencies where $2{\pi}$ ambiguities cannot be resolved. The immersion testing method, which is a transmission test while the sample is immersed in liquid, is very effective in reducing high frequency fringes in transmission measurements so that large dynamic range testing is possible for a non-null configuration. We developed a digital holographic microscope using liquid that can measure the high numerical aperture aspheric morphology of a sample. This system provides highly precise three-dimensional information on the sample. By improving the experimental method, choosing liquids which have similar refractive index to the sample, we can measure more accurate three-dimensional information on the samples.

Dynamic properties of the retinal neurons by using of the intracellular recording method (세포내 기록법으로써 검출한 망막 신경원의 동적 특성)

  • 이성종;정창섭;배선호
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.95-104
    • /
    • 1998
  • The dynamic properties of the 3rd-order neuron of the retina was investigated by using conventional intracellular recording techniques. Experiments were performed in the superfused retina-eyecup preparation of the channel catfish, Ictalurus punctatus. The cornea, iris, lens, and vitreous were removed by absorption with Kimwipe tissue under the dissection microscope thereby exposing the retina in a hemi -eyecup. The electrical signal was amplified by electrometer, viewed on oscilloscope. Regular signals from the cells were recorded on a penwriter and stored by data recorder and computer. Full-field, spot or annular light stimuli were generated on a computer monitor and focused onto the retina. Baclofen hyperpolarized the dark membrane potential, suppressed sustained component and enhanced transient component of the ON-sustained cell with a large transient component, but did not affect the surround antagonism of the cell. Baclofen selectively suppressed responses evoked by moving bar light stimuli on the ON-OFF transient cell. The results suggest that transient cells have directional selectivity in the inner retina. These dynamic properties of amacrine and ganglion cells were modulated by baclofen. Therefore, it is presumed that there is baclofen-induced directional selectivity in ON-OFF transient cells in the catfish retina.

  • PDF

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Development of Digital 3D Real Object Duplication System and Process Technology (디지털 3차원 실물복제기 시스템 및 공정기술 개발)

  • Kim D.S.;An Y.J.;Lee W.H.;Choi B.O.;Chang M.H.;Baek Y.J.;Choi K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.732-737
    • /
    • 2005
  • Distal 3D Real Object Duplication System(RODS) consists of 3D Scanner and Solid Freeform Fabrication System(SFFS). It is a device to make three-dimensional objects directly from the drawing or the scanning data. In this research, we developed an office type SFFS based on Three Dimensional Printing Process and a industrial SFFS using Dual Laser. An office type SFFS applied sliding mode control with sliding perturbation observer(SMCSPO) algorithm for control of this system. And we measured process variables about droplet diameter measurement and powder bed formation etc. through experiments. Also, in order to develop more elaborate and speedy system for large objects than existing SLS process, this study applies a new Selective Multi-Laser Sintering(SMLS) process and 3-axis dynamic Focusing Scanner for scanning large area instead of the existing $f\theta$ lens. In this process, the temperature has a great influence on sintering of the polymer. Also the laser parameters are considered like that laser beam power, scan speed, scan spacing. Now, this study is in progress to eveluate the effect of experimental parameters on the sintering process.

  • PDF

Advanced tube formation assay using human endothelial colony forming cells for in vitro evaluation of angiogenesis

  • Lee, Hyunsook;Kang, Kyu-Tae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.6
    • /
    • pp.705-712
    • /
    • 2018
  • The tube formation assay is a widely used in vitro experiment model to evaluate angiogenic properties by measuring the formation of tubular structures from vascular endothelial cells (ECs). In vitro experimental results are crucial when considered the advisability of moving forward to in vivo studies. Thus, the additional attentions to the in vitro assay is necessary to improve the quality of the pre-clinical data, leading to better decision-making for successful drug discovery. In this study, we improved the tube formation assay system in three aspects. First, we used human endothelial colony forming cells (ECFCs), which are endothelial precursors that have a robust proliferative capacity and more defined angiogenic characteristics compared to mature ECs. Second, we utilized a real-time cell recorder to track the progression of tube formation for 48 hours. Third, to minimize analysis error due to the limited observation area, we used image-stitching software to increase the microscope field of view to a $2{\times}2$ stitched area from the $4{\times}$ object lens. Our advanced tube formation assay system successfully demonstrated the time-dependent dynamic progression of tube formation in the presence and absence of VEGF and FGF-2. Vatalanib, VEGF inhibitor, was tested by our assay system. Of note, $IC_{50}$ values of vatalanib was different at each observation time point. Collectively, these results indicate that our advanced tube formation assay system replicates the dynamic progression of tube formation in response to angiogenic modulators. Therefore, this new system provides a sensitive and versatile assay model for evaluating pro- or anti-angiogenic drugs.

A study on the dynamic characteristics of exciting Flexural beam by ultrasonic wave (초음파에 의해서 가진되어지는 Flexural Beam의 동특성에 관한 연구)

  • Jeong, Sang-Hwa;Shin, Sang-Moon;Kim, Gwang-Ho;Lee, Sang-Hee;Kim, Ju-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.792-796
    • /
    • 2006
  • In recent years, the semiconductor industry and the optical industry is developed rapidly. The recent demand has expanded for optical components such as a optical lens, a optical semiconductor and a measuring instrument. Object transport systems are driven typically by the magnetic field and the conveyer belt. Recent industry requires more faster and efficient transport system. However, conventional transport systems are not adequate for transportation of optical elements and semiconductors. Because conveyor belts can damage precision optical elements by the contact force and magnetic systems can destroy the inner structure of semiconductor by the magnetic field. In this paper, the levitation transport system using ultrasonic wave is developed for transporting precision elements without damages. This transport system is using 2-mode ultrasonic wave excitation and flexural beam modes shapes are evaluated. It compared simulation results with experimental results

  • PDF