• Title/Summary/Keyword: Dynamic effects

Search Result 4,403, Processing Time 0.031 seconds

Dynamic Limit and Predatory Pricing Under Uncertainty (불확실성하(不確實性下)의 동태적(動態的) 진입제한(進入制限) 및 약탈가격(掠奪價格) 책정(策定))

  • Yoo, Yoon-ha
    • KDI Journal of Economic Policy
    • /
    • v.13 no.1
    • /
    • pp.151-166
    • /
    • 1991
  • In this paper, a simple game-theoretic entry deterrence model is developed that integrates both limit pricing and predatory pricing. While there have been extensive studies which have dealt with predation and limit pricing separately, no study so far has analyzed these closely related practices in a unified framework. Treating each practice as if it were an independent phenomenon is, of course, an analytical necessity to abstract from complex realities. However, welfare analysis based on such a model may give misleading policy implications. By analyzing limit and predatory pricing within a single framework, this paper attempts to shed some light on the effects of interactions between these two frequently cited tactics of entry deterrence. Another distinctive feature of the paper is that limit and predatory pricing emerge, in equilibrium, as rational, profit maximizing strategies in the model. Until recently, the only conclusion from formal analyses of predatory pricing was that predation is unlikely to take place if every economic agent is assumed to be rational. This conclusion rests upon the argument that predation is costly; that is, it inflicts more losses upon the predator than upon the rival producer, and, therefore, is unlikely to succeed in driving out the rival, who understands that the price cutting, if it ever takes place, must be temporary. Recently several attempts have been made to overcome this modelling difficulty by Kreps and Wilson, Milgram and Roberts, Benoit, Fudenberg and Tirole, and Roberts. With the exception of Roberts, however, these studies, though successful in preserving the rationality of players, still share one serious weakness in that they resort to ad hoc, external constraints in order to generate profit maximizing predation. The present paper uses a highly stylized model of Cournot duopoly and derives the equilibrium predatory strategy without invoking external constraints except the assumption of asymmetrically distributed information. The underlying intuition behind the model can be summarized as follows. Imagine a firm that is considering entry into a monopolist's market but is uncertain about the incumbent firm's cost structure. If the monopolist has low cost, the rival would rather not enter because it would be difficult to compete with an efficient, low-cost firm. If the monopolist has high costs, however, the rival will definitely enter the market because it can make positive profits. In this situation, if the incumbent firm unwittingly produces its monopoly output, the entrant can infer the nature of the monopolist's cost by observing the monopolist's price. Knowing this, the high cost monopolist increases its output level up to what would have been produced by a low cost firm in an effort to conceal its cost condition. This constitutes limit pricing. The same logic applies when there is a rival competitor in the market. Producing a high cost duopoly output is self-revealing and thus to be avoided. Therefore, the firm chooses to produce the low cost duopoly output, consequently inflicting losses to the entrant or rival producer, thus acting in a predatory manner. The policy implications of the analysis are rather mixed. Contrary to the widely accepted hypothesis that predation is, at best, a negative sum game, and thus, a strategy that is unlikely to be played from the outset, this paper concludes that predation can be real occurence by showing that it can arise as an effective profit maximizing strategy. This conclusion alone may imply that the government can play a role in increasing the consumer welfare, say, by banning predation or limit pricing. However, the problem is that it is rather difficult to ascribe any welfare losses to these kinds of entry deterring practices. This difficulty arises from the fact that if the same practices have been adopted by a low cost firm, they could not be called entry-deterring. Moreover, the high cost incumbent in the model is doing exactly what the low cost firm would have done to keep the market to itself. All in all, this paper suggests that a government injunction of limit and predatory pricing should be applied with great care, evaluating each case on its own basis. Hasty generalization may work to the detriment, rather than the enhancement of consumer welfare.

  • PDF

Study on the Short-Term Hemodynamic Effects of Experimental Cardiomyoplasty in Heart Failure Model (심부전 모델에서 실험적 심근성형술의 단기 혈역학적 효과에 관한 연구)

  • Jeong, Yoon-Seop;Youm, Wook;Lee, Chang-Ha;Kim, Wook-Seong;Lee, Young-Tak;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.224-236
    • /
    • 1999
  • Background: To evaluate the short-term effect of dynamic cardiomyoplasty on circulatory function and detect the related factors that can affect it, experimental cardiomyoplasties were performed under the state of normal cardiac function and heart failure. Material and Method: A total of 10 mongrel dogs weighing 20 to 30kg were divided arbitrarily into two groups. Five dogs of group A underwent cardiomyoplasty with latissimus dorsi(LD) muscle mobilization followed by a 2-week vascular delay and 6-week muscle training. Then, hemodynamic studies were conducted. In group B, doxorubicin was given to 5 dogs in an IV dose of 1 mg/kg once a week for 8 weeks to induce chronic heart failure, and simultaneous muscle training was given for preconditioning during this period. Then, cardiomyoplasties were performed and hemodynamic studies were conducted immediately after these cardiomyoplasties in group B. Result: In group A, under the state of normal cardiac function, only mean right atrial pressure significantly increased with the pacer-on(p<0.05) and the left ventricular hemodynamic parameters did not change significantly. However, with pacer-on in group B, cardiac output(CO), rate of left ventricular pressure development(dp/dt), stroke volume(SV), and left ventricular stroke work(SW) increased by 16.7${\pm}$7.2%, 9.3${\pm}$3.2%, 16.8${\pm}$8.6%, and 23.1${\pm}$9.7%, respectively, whereas left ventricular end-diastole pressure(LVEDP) and mean pulmonary capillary wedge pressure(mPCWP) decreased by 32.1${\pm}$4.6% and 17.7${\pm}$9.1%, respectively(p<0.05). In group A, imipramine was infused at the rate of 7.5mg/kg/hour for 34${\pm}$2.6 minutes to induce acute heart failure, which resulted in the reduction of cardiac output by 17.5${\pm}$2.7%, systolic left ventricular pressure by 15.8${\pm}$2.5% and the elevation of left ventricular end-diastole pressure by 54.3${\pm}$15.2%(p<0.05). With pacer-on under this state of acute heart failu e, CO, dp/dt, SV, and SW increased by 4.5${\pm}$1.8% and 3.1${\pm}$1.1%, 5.7${\pm}$3.6%, and 6.9${\pm}$4.4%, respectively, whereas LVEDP decreased by 11.7${\pm}$4.7%(p<0.05). Comparing CO, dp/dt, SV, SW and LVEDP that changed significantly with pacer-on, both under the state of acute and chronic heart failure, augmentation widths of these left ventricular hemodynamic parameters were significantly larger under the state of chronic heart failure(group B) than acute heart failure(group A)(p<0.05). On gross inspection, variable degrees of adhesion and inflammation were present in all 5 dogs of group A, including 2 dogs that showed no muscle contraction. No adhesion and inflammation were, however, present in all 5 dogs of group B, which showed vivid muscle contractions. Considering these differences in gross findings along with the following premise that the acute heart failure state was not statistically different from the chronic one in terms of left ventricular parameters(p>0.05), the larger augmentation effect seen in group B is presumed to be mainly attributed to the viability and contractility of the LD muscle. Conclusion: These results indicate that the positive circulatory augmentation effect of cardiomyoplasty is apparent only under the state of heart failure and the preservation of muscle contractility is important to maximize this effect.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF