• 제목/요약/키워드: Dynamic diagnosis

검색결과 362건 처리시간 0.036초

Successful High Flow Nasal Oxygen Therapy for Excessive Dynamic Airway Collapse: A Case Report

  • Park, Jisoo;Lee, Yeon Joo;Kim, Se Joong;Park, Jong Sun;Yoon, Ho Il;Lee, Jae Ho;Lee, Choon-Taek;Cho, Young-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • 제78권4호
    • /
    • pp.455-458
    • /
    • 2015
  • Excessive dynamic airway collapse (EDAC) is a disease entity of excessive reduction of the central airway diameter during exhalation, without cartilage collapse. An 80-year-old female presented with generalized edema and dyspnea at our hospital. The patient was in a state of acute decompensated heart failure due to pneumonia with respiratory failure. We accordingly managed the patient with renal replacement therapy, mechanical ventilation and antibiotics. Bronchoscopy confirmed the diagnosis of EDAC. We scheduled extubation after the improvement of pneumonia and heart condition. However, extubation failure occurred due to hypercapnic respiratory failure with poor expectoration. Her EDAC was improved in response to high flow nasal oxygen therapy (HFNOT). Subsequently, the patient was stabilized and transferred to the general ward. HFNOT, which generates physiologic positive end expiratory pressure (PEEP) effects, could be an alternative and effective management of EDAC. Further research and clinical trials are needed to demonstrate the therapeutic effect of HFNOT on EDAC.

동적분할 기법을 이용한 배전망의 정전복구 시스템에 관한 연구 (A Study on the Restoration System for Distribution Networks Using Dynamic Division Method)

  • 임찬호
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.64-72
    • /
    • 2003
  • 배전망은 그 구조가 매우 복잡하고, 수용가와 인접되어 있으므로 송전망에 비하여 사고의 발생도 매우 빈번하다. 또한 배전망에서의 사고는 수용가에게 직접적인 피해를 발생시킬 수 있다. 따라서 수용가의 피해를 줄이고 전력공급의 안정성 확보를 위한 배전망에서의 고장진단과 정전복구는 필수적으로 요구되는 기능이다. 배전망의 정전복구는 시간적인 제약성에 종속되며, 정전복구 과정에서 발생하는 스위칭 수를 최소화하는 것이 가장 중요한 요소이다. 폭, 모든 정전구역을 한번의 스위칭으로 복구하는 것이 가장 이상적이며, 그렇지 못한 경우 여러 번의 스위칭으로 복구하여야 한다. 본 논문에서는 조작되는 스위치의 수를 최소화시키기 위한 배전망의 정전 복구 시스템을 제안하였다. 제안된 시스템에서는 휴리스틱 탐색방법과 메타-알고리즘의 동적분할 기법의 계층구조를 사용하고 있다. 제안된 정전복구 시스템의 성능을 검증하기 위하여 모의 배전망을 대상으로 성능평가를 수행하였다.

주기적 충격하중을 받는 강 구조물의 구조건전성 평가 (Evaluation Using Dynamic Characteristic of Steel Structures under Periodical Impact Loads)

  • 김강석;나환선;이현주;이강민;유경석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.120-128
    • /
    • 2011
  • 변전소 구조물은 가스절연개폐기의 개폐로 유발되는 주기적인 충격하중을 받게 된다. 이러한 주기적인 충격하중은 구조물의 노후화 및 열화를 가속화하여 구조물의 일부 부재 혹은 전반적인 강성 감소를 초래할 수 있다. 본 연구에서는 이러한 주기적인 충격하중이 구조물에 미치는 영향을 정량적으로 평가하고, 손상 정도를 평가하는 방법을 선정하고자 한다. 따라서, 개략적인 손상 정도를 파악할 수 있는 효율적인 방법으로 인지되고 있는 시스템식별기법을 선정하였다. 선정된 기법에 대한 신뢰성을 검증하기 위해 3층 1경간 축소 모형을 대상으로 모의 손상실험 및 해석을 통해 모드형상 및 고유진동수를 산정하고 결과를 비교하였다.

Application of power spectral density function for damage diagnosis of bridge piers

  • Bayat, Mahmoud;Ahmadi, Hamid Reza;Mahdavi, Navideh
    • Structural Engineering and Mechanics
    • /
    • 제71권1호
    • /
    • pp.57-63
    • /
    • 2019
  • During the last two decades, much joint research regarding vibration based methods has been done, leading to developing various algorithms and techniques. These algorithms and techniques can be divided into modal methods and signal methods. Although modal methods have been widely used for health monitoring and damage detection, signal methods due to higher efficiency have received considerable attention in various fields, including aerospace, mechanical and civil engineering. Signal-based methods are derived directly from the recorded responses through signal processing algorithms to detect damage. According to different signal processing techniques, signal-based methods can be divided into three categories including time domain methods, frequency domain methods, and time-frequency domain methods. The frequency domain methods are well-known and interest in using them has increased in recent years. To determine dynamic behaviours, to identify systems and to detect damages of bridges, different methods and algorithms have been proposed by researchers. In this study, a new algorithm to detect seismic damage in the bridge's piers is suggested. To evaluate the algorithm, an analytical model of a bridge with simple spans is used. Based on the algorithm, before and after damage, the bridge is excited by a sine force, and the piers' responses are measured. The dynamic specifications of the bridge are extracted by Power Spectral Density function. In addition, the Least Square Method is used to detect damage in the bridge's piers. The results indicate that the proposed algorithm can identify the seismic damage effectively. The algorithm is output-only method and measuring the excitation force is not needed. Moreover, the proposed approach does not need numerical models.

Analysis of vibration characterization of a multi-stage planetary gear transmission system containing faults

  • Hao Dong;Yue Bi;Bing-Xing Ren;Zhen-Bin Liu;Yue, Li
    • Structural Engineering and Mechanics
    • /
    • 제88권4호
    • /
    • pp.389-403
    • /
    • 2023
  • In order to explore the influence of tooth root cracks on the dynamic characteristics of multi-stage planetary gear transmission systems, a concentrated parameter method was used to construct a nonlinear dynamic model of the system with 30-DOF in bending and torsion, taking into account factors such as crack depth, length, angle, error, time-varying meshing stiffness (TVMS), and damping. In the model, the energy method was used to establish a TVMS model with cracks, and the influence of cracks on the TVMS of the system was studied. By using the Runge- Kutta method to calculate the differential equations of system dynamics, a series of system vibration diagrams containing cracks were obtained, and the influence of different crack parameters on the vibration of the system was analyzed. And vibration testing experiments were conducted on the system with planetary gear cracks. The results show that when the gear contains cracks, the TVMS of the system will decrease, and as the cracks intensify, the TVMS will decrease. When cracks appear on the II-stage planetary gear, the system will experience impact effects with intervals of rotation cycles of the II-stage planetary gear. There will be obvious sidebands near the meshing frequency doubling, and the vibration trajectory of the gear will also become disordered. These situations will become more and more obvious as the degree of cracks intensifies. Through experiments, the theoretical results are in good agreement with experimental results, verifying the correctness of the theoretical model. This provides a theoretical basis for fault diagnosis and reliability research of the system.

[I-123]IPT SPECT를 이용한 도파민 재섭취부위의 영상화: 반정성적 분석방법을 이용한 정상인과 파킨슨병 환자의 차이 ([I-123]IPT SPECT Dopamine Reuptake Site Imaging: Differences in Normal Controls and Parkinson's Patients by Semiquantitative Analysis Methods)

  • 김희중;임주혁;양승오;류진숙;최윤영;이명종;이희경
    • 대한핵의학회지
    • /
    • 제30권1호
    • /
    • pp.35-46
    • /
    • 1996
  • Dopamine transporter concentrations have been known to decrease in Parkinson's disease (PD) or increase in Tourette's disorder. The purpose of this study was to evaluate the effectiveness of [I-123]N-(3-iodopropene-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-chlorophenyl) tropane (IPT) as an imaging agent for measuring changes in transporter concentrations with PD. IPT labelled with 6.69+/-0.64 mCi(247.53+/-23.68 MBq) of I-123 was intravenously injected into ten patients(age: 55+/-11) with PD, and six normal controls(NC)(age: 46+/-14) as a bolus. Dynamic SPECT scans of the brain were then performed for 5 minutes each over 120 minutes on a triple headed camera. Time activity curves were generated for the left basal ganglia(LBG), right basal ganglia(RBC), and occipital cortex(OCC). The statistical parameters included the time to peak activity, the contrast ratio of LBG and RBG to OCC at several time points, and the accumulated specific binding counts/mCi/pixel(ASBC) from 0 to 115 minutes. The uptake of IPT in the brains of PD and NC peaked within 10 minutes of injection in all subjects. The maximum target to background ratio in the basal ganglia of PD and NC occurred at 85+/-20 min and 110+/-6 min of injection, respectively. The BG/OCC ratios at 115 minutes for PD and NC were 2.15+/-0.54 and 4.26+/-0.73, respectively. The ASBC at 115 minutes for PD and NC were 152.91+/-50.09 and 289.51+/-49.00, respectively. The ratio of BG/OCC for the NC was significantly higher than the ratio for PD. SPECT data matched with clinical diagnosis for PDs. The ratio between BG and OCC and the ASBC for PD were clearly separated from NC and may be useful outcome measures for clinical diagnosis. The findings suggest that IPT may be a very useful tracer for early diagnosis of PD and study of dopamine reuptake site.

  • PDF

Tumor-like Presentation of Tubercular Brain Abscess: Case Report

  • Karki, Dan B.;Gurung, Ghanashyam;Sharma, Mohan R.;Shrestha, Ram K.;Sayami, Gita;Sedain, Gopal;Shrestha, Amina;Ghimire, Ram K.
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권4호
    • /
    • pp.231-236
    • /
    • 2015
  • A 17-year-old girl presented with complaints of headache and decreasing vision of one month's duration, without any history of fever, weight loss, or any evidence of an immuno-compromised state. Her neurological examination was normal, except for papilledema. Laboratory investigations were within normal limits, except for a slightly increased Erythrocyte Sedimentation Rate (ESR). Non-contrast computerized tomography of her head revealed complex mass in left frontal lobe with a concentric, slightly hyperdense, thickened wall, and moderate perilesional edema with mass effect. Differential diagnoses considered in this case were pilocytic astrocytoma, metastasis and abscess. Magnetic resonance imaging (MRI) obtained in 3.0 Tesla (3.0T) scanner revealed a lobulated outline cystic mass in the left frontal lobe with two concentric layers of T2 hypointense wall, with T2 hyperintensity between the concentric ring. Moderate perilesional edema and mass effect were seen. Post gadolinium study showed a markedly enhancing irregular wall with some enhancing nodular solid component. No restricted diffusion was seen in this mass in diffusion weighted imaging (DWI). Magnetic resonance spectroscopy (MRS) showed increased lactate and lipid peaks in the central part of this mass, although some areas at the wall and perilesional T2 hyperintensity showed an increased choline peak without significant decrease in N-acetylaspartate (NAA) level. Arterial spin labelling (ASL) and dynamic susceptibility contrast (DSC) enhanced perfusion study showed decrease in relative cerebral blood volume at this region. These features in MRI were suggestive of brain abscess. The patient underwent craniotomy with excision of a grayish nodular lesion. Abundant acid fast bacilli (AFB) in acid fast staining, and epithelioid cell granulomas, caseation necrosis and Langhans giant cells in histopathology, were conclusive of tubercular abscess. Tubercular brain abscess is a rare manifestation that simulates malignancy and cause diagnostic dilemma. MRI along with MRS and magnetic resonance perfusion studies, are powerful tools to differentiate lesions in such equivocal cases.

간담도스캔의 영상수집방법에 따른 담즙배출율의 비교분석 (A Comparative Analysis of GBEF According to Image Aquisition Method in Hepatobiliary Scan)

  • 김영선;서명덕;이완규;송재범
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.8-16
    • /
    • 2014
  • 간담도 스캔에서 GBEF의 산출은 정적영상법과 동적영상법으로 가능하다. 이번 연구를 통해 영상수집 방법에 따른 GBEF 차이를 알아보고, 정확한 GBEF를 산출하기 위한 방법을 강구하고자 한다. 본원의 환자 27명을 대상으로 하였으며, $^{99m}Tc$-mebrofenin을 정맥주사한 후 60분 동안은 정적영상법으로 영상을 수집하고 담낭이 잘 관찰되면 지방식(우유 $200m{\ell}$, 삶은 계란 1개)을 섭취하도록 하였다. 지방식 섭취 후 동적 영상법으로 60 sec/frame, 30분간 영상을 수집하고, 종료 후 60분 영상과 같은 조건으로 90분 영상을 수집하였다. 정적 GBEF는 지방식 전 후 정적 영상의 담낭계수를 이용하여 산출하고, 동적 GBEF는 시간-방사능곡선 상에 $T_{max}$$T_{min}$의 담낭계수를 이용하여 산출하였다. 또한 정적영상법의 지방식 전 영상과 동적영상법의 1분째 영상을 이용하여 지방식을 섭취하는 동안의 담즙배출량(초기담즙배출량)을 산출하였다. 결과는 $T_{max}$가 1분 이하인 경우는 20 case였으며, 정적영상법이 평균 $11.4{\pm}6.7%$ 높게 산출되었다(동적 : $40.1{\pm}21.7%$, 정적 : $51.5{\pm}23.6%$). $T_{max}$가 1분을 초과한 경우는 7 case였으며, 동적영상법이 평균 $-9.7{\pm}4.9%$ 높게 산출되었다(동적 : $31.0{\pm}19.7%$, 정적 : $21.3{\pm}19.4%$). 정확한 비교를 위해 영상법에 따른 담즙배출차이와 초기배출량을 지방식 전 담낭계수와의 비율로 부터 산출하였다. $T_{max}$가 1분 이하인 경우, 영상법간 차이는 평균 $16.7{\pm}13.6%$, 초기배출량은 평균 $12.7{\pm}13.8%$로, 오차범위 이내에서 일치하였다. 이는 영상법간 GBEF의 차이가 동적영상법이 시작되기 전에 이미 배출된 담즙때문이라는 것을 의미한다. $T_{max}$가 1분을 초과한 경우, 영상법간 차이는 평균 $-14.3{\pm}7.3%$, 초기배출량은 $-5.9{\pm}3.9%$로, 8.4% 차이가 났다. 이는 지방식 섭취를 시작한 시점부터 동적영상법을 시작한 후 일정 시점($T_{max}$)까지 계속 담즙이 집적되고 있음을 의미하며, 이 때문에 영상법간에 GBEF가 차이가 나는 것으로 판단된다. 정확히 30분 동안의 GBEF 산출하기 위해서, $T_{max}$가 9.5분 이상인 4 case를 추세 분석하여 GBEF를 산출한 결과, 평균 $57.2{\pm}20.4%$로, 정적영상법 (평균 $37.8{\pm}20.9%$) 보다는 20%정도, 동적영상법(평균 $42.0{\pm}16.2%$) 보다는 15% 정도 높게 산출되었다. 정적영상법은 비교적 간단하게 GBEF을 산출할 수 있으며, 환자의 움직임 등 여러 가지 오류로부터 영향을 적게 받는다는 장점이 있다. 반면에 $T_{max}$ 이전에 담낭자극을 시행한 경우이거나 환자의 상태에 따라서 담낭자극에 반응이 느린 경우엔 GBEF가 낮게 산출된다. 동적영상법은 담낭에서 담즙이 배출되는 양상을 분석할 수 있다는 장점이 있다. 배출이 지연되는 경우에도 T-A curve를 통해 $T_{max}$ 시점을 알 수 있기 때문에 정확한 GBEF를 산출할 수 있다. 하지만 지방식을 섭취한 후에 검사가 시작되기 때문에 지방식을 섭취하는 동안에 배출되는 답즙이 제외되어 GBEF가 낮게 산출된다. 연구 결과 간담도 스캔을 통해 정확한 GBEF를 산출하기 위해서는 우선적으로 동적영상법을 시행하여 T-A curve를 통해 담즙배출양상($T_{max}$의 시점)을 확인한 후에 두 영상법 중 적합한 GBEF를 선택하는 것이 바람직하다고 본다.

  • PDF

협력학습을 위한 웹 기반 지능형 교수 시스템에 관한 연구 : 도형학습을 위한 스케줄링 에이전트 시스템을 중심으로 (A Study on Web Based Intelligent Tutoring System for Collaborative Learning : A Case of Scheduling Agents Systems for Figure Learning)

  • 한선관;김세형;조근식
    • 한국지능정보시스템학회:학술대회논문집
    • /
    • 한국지능정보시스템학회 1999년도 추계학술대회-지능형 정보기술과 미래조직 Information Technology and Future Organization
    • /
    • pp.269-279
    • /
    • 1999
  • 본 연구는 Web상에서 원격 협력 학습을 위한 수준별 학습자 모집 스케줄링 에이전트의 설계와 구현에 관해 제안한다. 본 시스템의 구조는 원격 교사 모듈과 여러 명의 학습자, 그리고 이를 연결해 주는 스케줄링 Agents, 학습자를 진단할 수 있는 진단 Agent로 구성된다. 컴퓨터가 분산환경으로 발전됨에 따라서 교육의 변화도 가속화되었고, 지식의 공유와 정보의 공유가 원격 협력학습에 의하여 절실히 필요하게 되었다. 원격 협력 학습에서의 학습자는 동일한 과목과 주제에 흥미를 느끼는 여러 명의 아동이 동시에 학습할 수 있는 상황이 필요하며, 선행 지식 또한 비슷한 수준이어야 동일한 주제로 학습의 효과가 있다. 이런 학습자를 판단하기 위해서 진단 Agent가 학습자를 진단하며 스케줄링 Agents의 학습자 지식에 추가한 후 스케줄링 Agents가 학습자의 기본 사항과 요구 내용을 추론하여 비슷한 수준의 학습자를 연결한다. 교사 모듈은 전통적인 ITS의 구조의 교수 학습 모듈, 전문가모듈로 구성되어 교수 학습을 할 수 있다. 이렇게 여러 명의 학습자를 연결하여 협력학습을 하기 위해서는 학습자간의 요구사항과 지식 수준 그리고 학습 가능한 시간이 같아야 하는데 이를 위해 시간을 자원으로 하는 동적 자원 스케줄링(Dynamic Resource Scheduling)으로 모델링 하였다. 본 연구에서 도형학습을 기반으로 하는 실험을 통해 구현한 원격 협력학습을 위한 지능형 스케줄링 에이전트를 평가하였다.

  • PDF

임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용 (The methods for occlusal force measurement and their clinical applicatio)

  • 박지만;허성주;전윤식
    • 대한치과의사협회지
    • /
    • 제50권1호
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.