• 제목/요약/키워드: Dynamic diagnosis

검색결과 366건 처리시간 0.02초

Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계 (Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease)

  • 조정아;최정일;곽동석;김정균;배선근;정병천;이재태;이규보;강승완;우언조;김신우;손상균;채성철
    • 대한핵의학회지
    • /
    • 제28권2호
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성 (Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke)

  • 오근택;정홍량;임청환;조영기;하본철;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.323-331
    • /
    • 2011
  • 본 연구는 급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 임상적 유용성을 평가하고자 하였다. 급성 허혈성 뇌경색 증상으로 응급실로 내원한 환자 중 확산강조영상(DWI)의 병변의 크기가 3 cm 이상이고 역동적 자화율대조 조영증강 관류자기공명(DSC)영상, 동맥스핀표지 관류자기공명(ASL)영상을 모두 시행한 22명과 정량적 분석을 위한 정상대조군 36명을 대상으로 하였다. 사용된 장비로는 Siemens Magnetom Verio 3.0 T이고 12 Chanel Head Coil을 사용하였다. 정성적 평가는 rMTT, TTP, rCBF, rCBV, ASL지도의 병변 인지도평가와 확산강조영상과 병변의 크기 비교평가를 하였고 정량적 평가는 각 관류영상의 평균 상대값을 Mann-Whitney U test를 사용하여 병변 그룹과 정상군 그룹의 유의성을 분석한 결과는 다음과 같다. 첫째, 병변의 인지도평가에서 TTP(95.5%), rCBF(95.5%), 지도가 가장 높았고, 둘째, 최종 뇌경색부위 연관성은 rCBV와 rCBF지도가 높게 나타났다. 셋째, 정량적 분석에서는 병변그룹의 평균 상대값은 유의하게 나타났다(p<0.05). 동맥스핀표지 관류자기공명(ASL)영상은 높은 병변의 인지율을 보여 임상에서 적용가능하다 생각되며, 정량적 상대값은 제시하기 어렵지만 참고적 자료로 사용될 수 있을 것이며 향후 지속적 연구를 한다면 뇌경색의 조기진단, 허혈성 반영부의 존재여부와 범위, 혈류역동학적평가가 가능함으로써 치료방침을 정하고 예후를 파악하는데 ASL영상이 유용할 것으로 사료된다.

대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성 (Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.96-103
    • /
    • 1998
  • 목적 : 고식적인 자기공명혈관조영술 (MR Angiography, MRA) 기법으로는 영상화가 어려웠던 대동맥궁의 주요 분지들의 평가에 있어서 새로운 MR기법인 조영증강 MRA의 임상적 유용성을 알아보고, 그 화질을 사용한 코일의 종류에 따라 비교해 보고자 한다. 대상 및 방법 : 뇌혈관 질환을 의심하여 고식적인 기법으로 뇌 및 경동맥 MRA를 시행한 29명에서 전향적으로 Gd-DAPA 15-20ml를 일시에 손으로 주입한 후 대동맥궁과 그의 주요 분지들에 대해 3시기의 고속 MRA를 시행하여 그 화질을 분석하였다. MRA는 1.0T MR기종에서 3D-FISP기법으로 얻었으며 총 영상 획득 시간은 40-60초였다. 영상 분석은 무명동맥, 양측 총경동맥, 양측 쇄골하동맥과 양측 척추 동맥들의 기시부로부터 전장에 걸쳐 화질을 주관적으로 3등급(good; 명백히 정상소견을 보이는 경우, fair; 약간 낮은 신호를 보이나 정상으로 진단하기에 비교적 만족할 만한 경우, poor; 협착이 모호하거나, 인공물이나 너무 낮은 신호로 혈관을 볼 수 없어 카테터 혈관조영술을 요하는 경우)으로 나누어 평가하였으며, 양측 총경동맥의 분기(bifurcation) 부위에서는 고식적인 기법의 영상과 그 화질을 비교평가하였다. 또한 세가지 사용한 코일의 종류(CP body array 12예, CP neck array 9예, head-and-neck 8예)에 따른 화질 차이를 정성적 및 정량적(신호대 잡음비)으로 분석하였다. 결과 : 대동맥궁 주요 분지들의 전반적인 화질은 55% (16/29)에서 'good', 34%(10/29)에서 'fair'로 평가되어 대부분 고식적인 카테터 혈과조영술이 피요치 않을 정도로 만족할 만한 화질을 보였다. 양측 총경 동맥분지 부위에서는 65%(17/26)에서 고식적인 3D-TOF기법과 같거나 나은 영상을 보였다. CP body array 코일을 사용한 경우가 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 정성적 및 정량적으로 유의하게 나은 영상을 보였다(p<0.05). 결론 : 고속 조영증강 MRA기법은 단시간내 (40-60초)에 대동맥구의 주요 분지들을 그 기시부위부터 두개골 저부에 이르기까지 대부분에서 잘 나타내주므로 선별검사로서 임상적으로 유용하리라 생각되며 CP body array 코일을 사용하였을 경우에 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 좀더 나은 화질을 얻을 수 있으리라 생각된다.

  • PDF

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석 (LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies)

  • 김동환;김보현;최준일;오순남;나성은
    • 대한영상의학회지
    • /
    • 제83권2호
    • /
    • pp.331-343
    • /
    • 2022
  • 목적 국소 치료 후 잔존 간세포암 진단을 위한 LI-RADS 치료 반응(liver imaging reporting and data system treatment response; 이하 LR-TR)과 modified Response Evaluation Criteria in Solid Tumors (이하 mRECIST) 기준의 진단능을 체계적으로 비교한다. 대상과 방법 MEDLINE과 EMBASE에서 역동적 조영증강 CT 또는 MRI를 이용하여 LR-TR과 mRECIST의 진단능을 개인 내 비교한 원저를 검색하였다. 생존 종양에 대한 참조 표준은 수술을 통한 병리 진단을 사용하였다. 각 기준의 생존 카테고리에 대한 메타분석적 통합 민감도와 특이도는 bivariate random-effects model을 통해 계산하였고 bivariate meta-regression을 통해 비교하였다. 결과 총 다섯 개의 포함된 연구들에서(430명 환자들 및 631개 치료된 병변들), LR-TR 생존 카테고리의 병변별 통합 민감도와 특이도는 58% (95% 신뢰구간, 45%-70%)와 93% (95% 신뢰구간, 88%-96%)이었으며 mRECIST 생존 카테고리는 56% (95% 신뢰구간, 42%-69%)와 86% (95% 신뢰구간, 72%-94%)이었다. LR-TR 생존 카테고리는 mRECIST에 비하여 유의하게 높은 특이도를 보였으나(p < 0.01) 민감도는 유사하였다(p = 0.53). 결론 LR-TR 알고리즘은 국소 치료 후 병리학적 잔존 간세포암의 진단에 대하여 민감도의 유의한 차이 없이 mRECIST보다 높은 특이도를 보였다.

[I-123]IPT 약역학 컴퓨터시뮬레이션을 이용한 민감도 측정 및 간편화된 운반체 정량분석 방법들의 비교분석 연구 (The Measurement of Sensitivity and Comparative Analysis of Simplified Quantitation Methods to Measure Dopamine Transporters Using [I-123]IPT Pharmacokinetic Computer Simulations)

  • 손혜경;나상균;이희경;김희중
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.19-29
    • /
    • 1997
  • 목 적 : 본 연구의 목적은 IPT 약역학 컴퓨터시뮬레이션을 이용하여 혈류공급량, 도파민 운반체량 그리고 시간의 함수인 혈류와 도파민 운반체의 민감도를 측정하고 간편화된 정적 영상을 얻을 수 있는가의 가능성과 그 경우 도파민 운반체량의 변화를 어느 정도 반영하는가를 측정하고자 하는 것이었다. 또한 실제 결합능을 나타낸다고 가정된 $k_3/k_4$의 비를 반영하는 (BG-OCC)/OCC와 (ABBG-ABOCC)/ABOCC의 비를 이용한 방법과 그래프적 분석 방법의 정확성 및 유용성과 방사성의약품의 약역학을 분석하는 기법을 연구하고자 하였다. 방 법 : [I-123]IPT와 SPECT로 얻은 약 2시간 동적 선조체 시간방사능곡선, 동적 피 시간방사능곡선, 그리고 삼구획 역학모형을 이용, $K_1,\;k_2\;k_3\;k_4$ 속도상수들을 획득하였다. 위의 동적 피 시간방사능곡선과 속도상수들 중 혈류공급과 관련된 $K_l$ 또는 도파민 운반체량과 관련된 $k_3$의 양을 변경하면서 5분부터 5분씩 증가하여 120분까지의 혈류와 도파민 운반체의 민감도를 측정하였다. 또한 $k_3$의 양을 변화시킨 데이터를 이용하여 선조체와 후두엽에서의 시간방사능곡선을 계산한 후 각 방법의 정밀도를 측정하기 위해 (BG-OCC)/OCC와 $R_A$ 비값들과 그래프적 분석 방법을 이용하여 구한 $R_A$값들과 참값 $k_3/k_4$의 관계를 시간방사능곡선과 선형회귀 분석으로 계산하였다. 결 과 : 선조체와 후두엽에서의 $K_1,\;k_2\;k_3\;k_4$ 속도상수는 각각 $1.26{\pm}5.41%,\;0.044{\pm}19.58%,\;0.031{\pm}24.36%,\;0.008{\pm}22.78%$$1.36{\pm}4.76%,\;0.170{\pm}6.89%,\;0.007{\pm}23.89%,\;0.007{\pm}45.09%$이었다. 이들 속도상수를 이용하여 얻은 혈류 민감도와 도파민 운반체의 민감도는 30분, 60분, 90분, 120분에 각각 0.50, 0.35, 0.29, 0.23 그리고 0.19, 0.40, 0.53, 0.61이었다. 실제 속도상수의 비 $k_3/k_4$에 대한 (BG-OCC)/OCC와 $R_A,\;R_v$간의 상관계수는 각각 0.983, 0.984, 0.999이었으며 그때의 기울기는 각각 1.76, 0.47, 1.25이었다. 결 론 : IPT 약역학은 시간이 흐름에 따라 혈류량의 변동에 비해 도파민 운반체량의 변동에 더욱 민감한 경향을 보였으며 $k_3/k_4$에 대한 (BG-OCC)/OCC, $R_A,\;R_v$의 결과간에 좋은 상관관계를 가졌다. 따라서 이러한 약역학 컴퓨터시뮬레이션이 SPECT 영상을 이용한 도파민 운반체 또는 수용체 정량분석을 최적화하는데 매우 유용할 것으로 생각된다.

  • PDF