• 제목/요약/키워드: Dynamic centrifuge model tests

검색결과 37건 처리시간 0.021초

유효응력모델을 이용한 침매터널의 동적거동 해석 (Dynamic Analysis of an Immersed Tunnel using an Effective Stress Model)

  • 박성식;문홍득
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.51-58
    • /
    • 2008
  • The George Massey immersed tunnel passes the Fraser River near Vancouver, Western Canada. In this paper, dynamic analysis of the tunnel on sandy soils was performed using an effective stress constitutive model called UBCSAND. This model is able to calculate pore pressure rise and resulting tunnel deformation due to cyclic loading. Centrifuge tests conducted at RPI are used to verify the model performance. Centrifuge tests consist of 3 models: Model 1 is designed for an original ground condition, Model 2 for a ground improvement by compaction method, Model 3 for a ground improvement by gravel drainage. The results of centrifuge Model 1 are presented and compared with predictions of UBCSAND model. This model well captured the results of centrifuge test and therefore can be used to predict dynamic behavior of similar tunnels or underground structures on sandy soils.

  • PDF

액상화 지반에 대한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests on Liquefied Sand Grounds)

  • 김성렬;황재익;;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.

  • PDF

Nonlinear numerical analyses of a pile-soil system under sinusoidal bedrock loadings verifying centrifuge model test results

  • Kim, Yong-Seok;Choi, Jung-In
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.239-255
    • /
    • 2017
  • Various centrifuge model tests on the pile foundations were performed to investigate fundamental characteristics of a pile-soil-foundation system recently, but it is hard to find numerical analysis results of a pile foundation system considering the nonlinear behavior of soil layers due to the dynamic excitations. Numerical analyses for a pile-soil system were carried out to verify the experimental results of centrifuge model tests. Centrifuge model tests were performed at the laboratory applying 1.5 Hz sinusoidal base input motions, and nonlinear numerical analyses were performed utilizing a finite element program of P3DASS in the frequency domain and applying the same input motions with the intensities of 0.05 g~0.38 g. Nonlinear soil properties of soil elements were defined by Ramberg-Osgood soil model for the nonlinear dynamic analyses. Nonlinear numerical analyses with the P3DASS program were helpful to predict the trend of experimental responses of a centrifuge model efficiently, even though there were some difficulties in processing analytical results and to find out unintended deficits in measured experimental data. Also nonlinear soil properties of elements in the system can be estimated adequately using an analytical program to compare them with experimental results.

유효응력모델을 이용한 동적 원심모형실험의 수치해석 (Numerical Analysis of Dynamic Centrifuge Model Tests Using an Effective Stress Model)

  • 박성식;김영수
    • 한국지반공학회논문집
    • /
    • 제22권1호
    • /
    • pp.25-34
    • /
    • 2006
  • 본 연구에서는 비교적 높은 초기 유효응력을 가진 지반구조물의 액상화연구에 사용된 동적 원심모형실힘결과를 이용하여 유효응력모델검증에 관한 연구를 수행하였다. 원심모형 지반은 최대 유효응력 380kPa를 가진 충분히 포화된 느슨한 Nevada 모래 지반으로 구성되었으며, 수치해석에서는 1차원의 기둥형태로 가정하였다. 수치해석에 이용한 두 종류의 원심모형실험에서는 상당한 깊이(37m 및 22m)까지도 액상화가 발생하였으나, 깊이에 따른 액상화발생 경향은 경험적 액상화 평가방법과 상반된 결과를 보였다. 즉, 원심모형실험에서 계측된 과잉간극수압을 기준으로 해석하였을 때, 액상화는 모형지반의 윗부분에서 먼저 발생한 후 점차적으로 아랫부분으로 이동함을 알았다. 이와 같은 실험결과는 수치해석에서 비교적 잘 예측된 것으로 판단되었다 원심모형 지반의 초기 포화도와 원심력 증가에 따른 지반의 상대밀도 증가가 액상화모형실험의 수치해석에서 중요한 역할을 함을 알 수 있었다.

Evaluation of the effect of rubble mound on pile through dynamic centrifuge model tests

  • Jungwon Yun;Jintae Han
    • Geomechanics and Engineering
    • /
    • 제33권4호
    • /
    • pp.415-425
    • /
    • 2023
  • Pile-supported wharves, port structures that support the upper deck, are installed on sloping ground. The sloping ground should be covered with a rubble mound or artificial blocks to protect the interior material from erosion caused by wave force. The behavior of the pile may vary during an earthquake if a rubble mound is installed on the slope. However, studies evaluating the effect of rubble mound on the pile during an earthquake are limited. Here, we performed dynamic centrifuge model tests to evaluate the dynamic behavior of piles installed in a slope reinforced with rubble mound. In the structure, some sections (single-pile, 2×2 group-pile) were selected for the experiment. The moment of the group-pile decreased by up to 26% upon installation of the rubble mound, whereas the moment of the single-pile increased by up to 41%, thus demonstrating conflicting results.

동적 원심모형시험을 통한 지반 및 상부 구조물의 지진 하중 특성 (Dynamic Centrifuge Modeling for Evaluating Seismic Loads of Soil-Foundation-Structures)

  • 이세현;김동수;추연욱;박홍근;김동관
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.192-200
    • /
    • 2010
  • Korea is part of a region of low or moderate seismic zone in which few earthquakes have been monitored, so it is difficult to approve design ground motions and seismic responses on structures from response spectrum. In this study, a series of dynamic centrifuge model tests for demonstrating seismic amplification characteristics in soil-foundation-structure system were performed using electro-hydraulic shaking table mounted on the KOCED 5.0 m radius beam centrifuge at KAIST in Korea. The soil model were prepared by raining dry sand and $V_S$ profiles were determined by performing bender element tests before shaking. The foundation types used in this study are shallow embedded foundation and deep basement fixed on the bottom. Total 7 building structures were used and the response of building structures were compared with response spectrum from the acceleration records on surface.

  • PDF

상사법칙 검증을 위한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests for Similitude Laws)

  • 김성렬;황재익;김명모
    • 한국지반공학회논문집
    • /
    • 제22권5호
    • /
    • pp.59-67
    • /
    • 2006
  • 동일한 흙으로 조성된 모형지반에 대하여 1-g 모형실험과 원심모형실험을 수행하고 그 결과를 비교하였다. 원형지반은 10m 두께의 수평하고 느슨한 포화 사질토 지반으로 가정하였다. 1-g 모형실험은 1/20 축소모형, 원심모형실험은 1/40 축소모형을 이용하였다. 원심모형실험의 경우 점성유체를 사용하여 동적시간에 대한 상사비와 과잉간극수압소산시간에 대한 상사비가 동일하도록 하였다. 원심모형실험의 계측결과는 원형지반의 거동으로 가정하였다. 그리고, 1-g모형실험에 정상상태개념 및 두 가지 시간상사비 등을 적용하여 원형지반의 거동을 모사하고자 하였다. 동일한 위치에서의 과잉간극수압, 지반가속도 그리고 지표 침하량 등을 계측하여 비교하였다. 실험결과 지반의 투수계수가 작아서 진동 중 과잉간극수압 소산의 영향이 작고, 소산시간상사비를 적절하게 결정하면 1-g 모형실험으로부터 원형지반의 과잉간극수압 거동을 모사할 수 있는 것으로 나타났다.

원심모형실험을 이용한 무리말뚝의 동적 p-y 곡선 산정 (Evaluation of Dynamic p-y Curves of Group Piles Using Centrifuge Model Tests)

  • ;;김성렬
    • 한국지반공학회논문집
    • /
    • 제34권5호
    • /
    • pp.53-63
    • /
    • 2018
  • 무리말뚝의 내진설계를 수행할 때 지반-말뚝 동적상호작용을 고려하는 것이 중요하다. 특히, 동적하중을 받는 무리말뚝의 횡방향 저항력은 무리말뚝 효과에 의하여 단일말뚝과 비교하여 감소한다. 그러나, 지금까지 지진하중을 받는 무리말뚝의 동적 무리말뚝 효과를 제안한 연구는 매우 부족한 실정이다. 그러므로, 본 연구에서는 건조 모래지반에 설치된 $3{\times}3$ 무리말뚝에 대한 동적 원심모형실험을 수행하여 무리말뚝 효과를 산정하였다. 이 무리말뚝 효과는 동적 p-y 곡선에서 극한 횡방향 지반반력과 지반반력계수에 대한 보정계수(multiplier)를 적용하여 고려하였다. 그리고, 본 연구에서 얻어진 동적 p-y 곡선을 Beam on Nonlinear Winkler Foundation 모델을 이용한 비선형 동해석에 적용하여 그 적용성을 검증하였다. 그 결과, 본 연구에서 제안한 무리말뚝의 보정계수가 원심모형실험 결과를 잘 모사할 수 있는 것으로 나타났다.

가상고정점기법이 적용된 잔교식 구조물의 응답스펙트 럼해석법 개선사항 도출 연구 (Study on the Improvement of Response Spectrum Analysis of Pile-supported Wharf with Virtual Fixed Point)

  • 윤정원;한진태
    • 한국지진공학회논문집
    • /
    • 제22권6호
    • /
    • pp.311-322
    • /
    • 2018
  • As a method of seismic-design for pile-supported wharves, equivalent static analysis, response spectrum analysis, and time history analysis method are applied. Among them, the response spectrum analysis is widely used to obtain the maximum response of a structure. Because the ground is not modeled in the response spectrum analysis of pile-supported wharves, the amplified input ground acceleration should be calculated by ground classification or seismic response analysis. However, it is difficult to calculate the input ground acceleration through ground classification because the pile-supported wharf is build on inclined ground, the methods to calculate the input ground acceleration proposed in the standards are different. Therefore, in this study, the dynamic centrifuge model tests and the response spectrum analysis were carried out to calculate the appropriate input ground acceleration. The pile moment in response spectrum analysis and the dynamic centrifuge model tests were compared. As a result of comparison, it was shown that the response spectrum analysis results using the amplified acceleration in the ground surface were appropriate.

원심모형 실험을 통한 궤도지지말뚝구조의 동적 거동 평가 (Dynamic Behavior Evaluation of Pile-Supported Slab Track System by Centrifuge Model Test)

  • 유민택;이명재;백민철;추연욱;이일화
    • 한국지반공학회논문집
    • /
    • 제35권2호
    • /
    • pp.5-17
    • /
    • 2019
  • 철도하중 및 지진하중 재하 시 궤도지지말뚝 구조의 동적 거동 평가를 위해 동적원심모형 실험을 수행하였다. 실험의 변수는 연약지반의 깊이와 성토체의 높이로 결정하였으며, 총 4가지 경우에 대해 실험을 수행하였다. 연약지반 깊이는 실제 연약지반층에 고속철도를 부설한 호남고속철도의 익산-정읍 구간의 시추주상도를 분석하여 결정하였으며, 성토체의 높이는 일반적인 고속철도의 성토체 높이 범위의 하한 값과 상한 값으로 결정하였다. 실험 결과, 연약지반 깊이 대비 성토체 높이 비율이 높을 수록 말뚝에 작용하는 최대 휨모멘트 값이 크게 평가되었다. 또한, 실험조건 내에서 부설되는 궤도지지말뚝 구조는 단주기 지진파에 대해서는 국내 내진설계 기준의 최대 지진하중인 0.22g에 대해서까지 안전한 것으로 확인되었다. 그러나, 장주기 지진파에 대해서는 재현주기 2400년 지진인 0.22g로 가진시 말뚝의 균열 모멘트가 초과되었다. 일련의 실험결과를 바탕으로, 본 논문에 기술된 연약지반 깊이와 성토체 높이 범위 내에서 궤도지지말뚝 일반 단면에 대한 연약지반 대비 성토체 높이 비율 기준을 제시하였다.