• Title/Summary/Keyword: Dynamic X-ray

Search Result 220, Processing Time 0.022 seconds

Mass and energy of erupting plasma associated with a coronal mass ejection in X-rays and EUV

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Moon, Yong-Jae;Kim, Kap-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.85.1-85.1
    • /
    • 2015
  • We investigate the mass and energy of erupting plasma observed in X-rays and EUV, which is associated with a coronal mass ejection (CME) and an X-class flare. The erupting plasma was observed by both the X-ray telescope (XRT) on Hinode and the Atmospheric Imaging Assembly (AIA) on Solar Dynamic Observatory (SDO). We estimate the emission measures of the erupting plasma using a differential emission measure method. The plasma erupts with a loop-like structure in X-ray and EUV. We estimate the mass of erupting plasma assuming a cylinder structure. In addition, we estimate the radiative loss, thermal conduction, thermal, and kinetic energies of the eruptive hot plasma. We find that the thermal conduction timescale is much shorter than the duration of the eruption. This result implies that additional heating during the eruption may be required to explain the hot plasma observations in X-rays.

  • PDF

Activation energy for the loss of substitutional carbon in $Si_{0.984}C_{0.016}$ grown by solid phase epitaxy

  • Kim, Yong-Jeong;Kim, Tae-Joon;Park, Byungwoo;Song, Jong-Han
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.2
    • /
    • pp.50-54
    • /
    • 2000
  • We studied the synthesis of S $i_{1-x}$ Cx (x=0.016) epitaxial layer using ion implantation and solid phase epitaxy (SPE). The activation energy Ea was obtained for the loss of substitutional carbon using fourier transform-infrared spectroscopy (FTIR) and high-resolution x-ray diffraction (HR-XRD). In FTIR analysis, the integrated peak intensity was used to quantify the loss of carbon atoms from substitutional to interstitial sites during annealing. The substitutional carbon contents in S $i_{0.984}$ $C_{0.016}$ were also measured using HR-XRD. By dynamic simulations of x-ray rocking curves, the fraction of substitutional carbon was obtained. The effects of annealing temperature and time were also studied by comparing vacuum furnace annealing with rapid thermal annealing (RTA))))))

  • PDF

Study for X-ray detector using liquid crystal modulator (Liquid crystal modulator를 이용한 엑스선 검출기에 관한 연구)

  • Heo, Seung-Uk;Cho, Sung-Ho;Kim, Yoon-Seok;Kim, Young-Bin;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.5-9
    • /
    • 2009
  • The trend of Digital x-ray Detector research is to improve resolution of image and to embody large area imaging as well as dynamic moving imaging, etc. This research is divided with indirect conversion method and direct conversion method by radiation conversion process. Each conversion method has problems such as decrease of resolution from light scattering in indirect method case and not only low system stability but also difficult in dynamic moving imaging in direct method case. X-ray detector using liquid crystal has been researching to solve these problems, but it is difficulty in uniform injection of liquid crystal because of its structural properties. Therefore, this study suggests the structure which solves present problem. Also the possibility of suggested structure was investigated using simulation.

  • PDF

Radio and Hard X-ray Study of the 2011 August 09 Flare

  • Hwangbo, Jung-Eun;Bong, Su-Chan;Lee, Jeongwoo;Lee, Dae-Young;Park, Seong-Hong;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2013
  • The 2011 August 09 Flare is one of the largest X-ray flares of Sunspot Cycle 24 to attract a lot of attention for its various activities detected in coronal images. In this study we concern ourselves mostly on information of high energy electrons produced during this flare provided by hard X ray data from the Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) and radio data from the Korean Solar Radio Burst Locator (KSRBL) and Ondrejov. EUV images obtained by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory are used to provide the context of magnetic reconnection. In our results, (1) HXR spectra have a rich spectral morphology. Initially it could be fit by one thermal component (T~30MK) and one single power law nonthermal spectrum, but later a better fit could be made by introducing an additional thermal component (T~55 MK). (2) Time delays between the KSRBL burst and the RHESSI hard X-ray emission were found which are more obvious at low frequencies and insignificant at high frequencies. (3) The HXR source lies in the core of the quadrupolar active region. In our interpretation based on AIA 94 A images, the outer part of the active region erupted to be blown out, leaving the intense hard X-ray emission concentrated in the core. We relate the appearance of the second thermal component to the evolution of the AIA 171 and 94 A images. The time delays of microwave peaks to HXR peaks are interpreted as indicating presence of trapped electrons in larger closed magnetic loops. With these result we conclude that the hard X ray and microwaves are due to impulsive acceleration in the low and high heights and a sigmoidal reconnection scenario.

  • PDF

System of a Selenium Based X-ray Detector for Radiography (일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템)

  • Lee, D.G.;Park, J.K.;Choi, J.Y.;Ahn, S.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

Experimental Study on Deformation and Failure Behavior of Limestones under Dynamic Loadings (동적하중 하에서 석회암의 변형 및 파괴거동에 관한 실험적 연구)

  • Kang, Myoung-Soo;Kang, Hyeong-Min;Kim, Seung-Kon;Cheon, Dae-Sung;Kaneko, Katsuhiko;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.339-345
    • /
    • 2012
  • Information on the deformation behavior and fracture strength of rocks subjected to dynamic loadings is important to stability analyses of underground openings underground vibration due to rock blasts, earthquakes and rock bursts. In this study, Split Hopkinson Pressure Bar (SHPB) system was applied to estimate dynamic compressive and tensile fracture strengths of limestone and also examine deformation behavior of limestones under dynamic loadings. A micro-focus X-ray CT scanner was used to observe non-destructively inside the impacted limestone specimens. From the dynamic tests, it was revealed that the limestone have over 140MPa dynamic compressive strength and the strain-rate dependency of the strength. Dynamic Brazilian tensile strength of the limestone exceeds 21MPa and shows over 3 times static Brazilian tensile strength.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

X-ray Photoelectron Spectroscopic Analysis of Modified MWCNT and Dynamic Mechanical Properties of E-beam Cured Epoxy Resins with the MWCNT

  • Lee, Young-Seak;Im, Ji-Sun;Yun, Seok-Min;Nho, Young-Chang;Kang, Phil-Hyun;Jin, Hang-Kyo
    • Carbon letters
    • /
    • v.10 no.4
    • /
    • pp.314-319
    • /
    • 2009
  • The surface treatment effects of reinforcement filler were investigated based on the dynamic mechanical properties of mutiwalled carbon nanotubes (MWCNTs)/epoxy composites. The as-received MWCNTs(R-MWCNTs) were chemically modified by direct oxyfluorination method to improve the dispersibility and adhesiveness with epoxy resins in composite system. In order to investigate the induced functional groups on MWCNTs during oxyfluorination, X-ray photoelectron spectroscopy was used. The thermo-mechanical property of MWCNTs/epoxy composite was also measured based on effects of oxyfluorination treatment of MWCNTs. The storage modulus of MWCNTs/epoxy composite was enhanced about 1.27 times through oxyfluorination of MWCNTs fillers at $25^{\circ}C$. The storage modulus of oxyfluorinated MWCNTs (OF73-MWCNTs) reinforced epoxy composite was much higher than that of R-MWCNTs/epoxy composite. It revealed that oxygen content led to the efficient carbon-fluorine covalent bonding during oxyfluorination. These functional groups on surface modified MWCNTs induced by oxyfluorination strikingly made an important role for the reinforced epoxy composite.

Wide-bandwidth SQUID Current Amplifier and Control Electronics for X-ray Microcalorimeter (X-선 미소열량계 신호 검출을 위한 광대역 SQUID 전류증폭기와 조절 회로)

  • 김진목;이용호;권혁찬;김기웅;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • Wide-bandwidth SQUID current amplifier and its control electronics have been constructed for detecting pulse outputs of a superconducting microcalorimeter. The current amplifier made of a double relaxation oscillation SQUID (DROS) has a bandwidth of 1.2 MHz and typical white noise level of about 6 pA/(equation omitted) Hz. To increase the dynamic range of the current amplifier, the flux-locked loop (FLL) has additional circuits to reset the integrator and to count reset numbers which present the number of passed flux quanta. In this system, dynamic range covers from -65 mA to +65 mA. SQUID electronics are controlled by software to get the optimum FLL condition, and to control the current to bias the transition edge sensor (TES). The electronics are shielded from the outside electromagnetic noises by using an aluminum case of 66 mm ${\times}$ 25 mm ${\times}$ 100 mm, and consist of 2 separate printed-circuit-boards for the current amplifier and the control electronics, respectively. The SQUID current amplifier and its control electronics will be used in TESs for detecting photons such as UV and X-ray with high energy resolution.

  • PDF

Multi-Channel Data Acquisition System Design for Spiral CT Application

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yun Yi;Kwak, Sung-Woo;Cho, Kyu-Sung;Park, Jung-Byung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.468-470
    • /
    • 2002
  • We have designed X-ray detection system and multi-channel data acquisition system for Spiral CT application. X-ray detection system consists of scintillator and photodiode. Scintillator converts X-ray into visible light. Photodiode converts visible light into electrical signal. The multi-channel data acquisition system consists of analog, digital, master and backplane board. Analog board detects electrical signal and amplifies signal by 140dB. Digital board consists of MUX(Multiplex) which routes multi-channel analog signal to preamplifier, and ADC(Analog to Digital Converter) which converts analog signal into digital signal. Master board supplies the synchronized clock and transmits the digital data to image reconstructor. Backplane provides electrical power, analog output and clock signal. The system converts the projected X-ray signal over the detector array with large gain, samples the data in each channel sequentially, and the sampled data are transmitted to host computer in a given time frame. To meet the timing limitation, this system is very flexible since it is implemented by FPGA(Field Programmable Gate Array). This system must have a high-speed operation with low noise and high SNR(signal to noise ratio), wide dynamic range to get a high resolution image.

  • PDF