• 제목/요약/키워드: Dynamic Seismic Analysis

검색결과 1,411건 처리시간 0.03초

Seismic performance assessment of steel building frames equipped with a novel type of bending dissipative braces

  • Taiyari, Farshad;Mazzolani, Federico M.;Bagheri, Saman
    • Steel and Composite Structures
    • /
    • 제33권4호
    • /
    • pp.525-535
    • /
    • 2019
  • The seismic performance of steel frames equipped with a particular type of bending dissipative braces (BDBs) having U elements, which has recently been introduced and tested by the authors, is investigated. For this purpose, two structural systems, i.e., simple and dual steel building frames, both with diagonal BDBs and different number of stories, are considered. After providing a design method of this new BDB, the detailed structural models are developed in the OpenSees platform to perform nonlinear dynamic analyses. Seismic performance factors like ductility, overstrength, response modification and deflection amplification factors are calculated using incremental dynamic analysis (IDA). In addition, to assess the damage probability of the structural models, their seismic fragilities are developed. The results show high energy dissipation capacity of both structural systems while the number of U elements needed for the bracing system of each story in the moment frames are less than those in the corresponding non-moment (simple) frames. The average response modification and deflection amplification factors for both structural schemes are obtained about 8.6 and 5.4, respectively, which are slightly larger than the corresponding recommended values of ASCE for the typical buckling-restrained braces (BRBs).

Sensitivity analysis of mass ratio effect on settlement and seismic response of shallow foundation using numerical simulation

  • Kil-Wan Ko;Jeong-Gon Ha;Jinsun Lee;Gye-Chun Cho
    • Geomechanics and Engineering
    • /
    • 제34권6호
    • /
    • pp.649-664
    • /
    • 2023
  • Structural inertial interaction is a representative the effect of dynamic soil-foundation-structure interaction (SFSI), which leads to a relative displacement between soil and foundation, period lengthening, and damping increasing phenomena. However, for a system with a significantly heavy foundation, the dynamic inertia of the foundation influences and interacts with the structural seismic response. The structure-to-foundation mass ratio (MR) quantifies the distribution of mass between the structure and foundation for a structure on a shallow foundation. Although both systems exhibit the same vertical factor of safety (FSv), the MR and corresponding seismic responses attributed to the structure and foundation masses may differ. This study explored the influence of MR on the permanent deformation and seismic response of soil-foundation-structure system considering SFSI via numerical simulations. Given that numerous dimensionless parameters of SFSI described its influence on the structural seismic response, the parameters, except for MR and FSv, were fixed for the sensitivity analysis. The results demonstrated that the foundation inertia of heavier foundations induced more settlement due to sliding behavior of heavily-loaded systems. Moreover, the structural inertia of heavier structures evidently exhibited foundation rocking behavior, which results in a more elongated natural period of the structure for lightly-loaded systems.

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • 해양환경안전학회지
    • /
    • 제26권3호
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

리히터 규모 7.0의 지진에 대응하는 MPS 면진받침의 필로티 구조물에 대한 내진성능 평가 - 비선형 동적 해석 (Seismic Performance Evaluation for Piloti Structures of MPS Seismic Isolation Device in Response to Earthquakes on the Richter Scale 7.0 - Nonlinear Dynamic Analysis)

  • 조한민;허종완
    • 대한토목학회논문집
    • /
    • 제41권1호
    • /
    • pp.13-20
    • /
    • 2021
  • 최근 우리나라는 주거 및 주차 공간의 확보를 위해 다양한 필로티 구조물이 건설되어 왔다. 하지만 이러한 필로티 구조물은 1층에 주차 공간을 확보하기 위해 벽체가 없는 돌출된 기둥의 형태로 건설되어 왔다. 이러한 형태는 지진 발생 시 일반적인 구조물에 비해 상대적으로 기둥의 파손이 쉽게 발생하며, 이러한 파손은 구조물의 붕괴로 이어질 수 있다. 따라서 본 연구에서는 MPS (Multi Performance System) 면진받침을 활용한 필로티 구조물의 안전성 확보에 대한 연구를 수행하였다. 기존에 건설되어 있는 필로티 구조물에 대해 MPS 면진받침 설치 유무에 따른 비선형 동적 해석을 수행하고 해석결과를 비교 및 분석하였다. 최종적으로 각각의 내진성능 평가를 수행하고 MPS 면진받침의 성능을 검증하였다.

Seismic performance evaluation of a steel slit damper for retrofit of structures on soft soil

  • Mahammad Seddiq Eskandari Nasab;Jinkoo Kim;Tae-Sang Ahn
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.93-101
    • /
    • 2024
  • This paper presents an experimental and analytical study on a steel slit damper designed as an energy dissipative device for earthquake protection of structures considering soil-structure interaction. The steel slit damper is made of a steel plate with a number of slits cut out of it. The slit damper has an advantage as a seismic energy dissipation device in that the stiffness and the yield force of the damper can be easily controlled by changing the number and size of the vertical strips. Cyclic loading tests of the slit damper are carried out to verify its energy dissipation capability, and an analytical model is developed validated based on the test results. The seismic performance of a case study building is then assessed using nonlinear dynamic analysis with and without soil-structure interaction. The soil-structure system turns out to show larger seismic responses and thus seismic retrofit is required to satisfy a predefined performance limit state. The developed slit dampers are employed as a seismic energy dissipation device for retrofitting the case study structure taking into account the soil-structure interaction. The seismic performance evaluation of the model structure shows that the device works stably and dissipates significant amount of seismic energy during earthquake excitations, and is effective in lowering the seismic response of structures standing on soft soil.

Seismic response of operational tunnels to earthquakes with foreshocks or aftershocks

  • Junyoung Lee;Jae-Kwang Ahn;Byungmin Kim
    • Geomechanics and Engineering
    • /
    • 제38권6호
    • /
    • pp.621-631
    • /
    • 2024
  • In designing earthquake-resistant structures, we traditionally select dynamic loads based on the recurrence period of earthquakes, using individual seismic records or aligning them with the design spectrum. However, these records often represent isolated waveforms lacking continuity, underscoring the need for a deeper understanding of natural seismic phenomena. The Earth's crustal movement, both before and after a significant earthquake, can trigger a series of both minor and major seismic events. These minor earthquakes, which often occur in short time before or after the major seismic events, prompt a critical reassessment of their potential impact on structural design. In this study, we conducted a detailed tunnel response analysis to assess the impact of both single mainshock and multiple earthquake scenarios (including foreshock-mainshock and mainshock-aftershock sequences). Utilizing numerical analysis, we explored how multiple earthquakes affect tunnel deformation. Our findings reveal that sequential seismic events, even those of moderate magnitude, can exert considerable stress on tunnel lining, resulting in heightened bending stress and permanent displacement. This research highlights a significant insight: current seismic design methodologies, which predominantly focus on the largest seismic intensity, may fail to account for the cumulative impact of smaller, yet frequent, seismic events like foreshocks and aftershocks. Our results demonstrate that dynamic analyses considering only a single mainshock are likely to underestimate the potential damage (i.e., ovaling deformation, failure lining, permanent displacement etc.) when compared to analyses that incorporate multiple earthquake scenarios.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

An evaluation of the seismic response of symmetric steel space buildings

  • Yon, Burak
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.399-412
    • /
    • 2016
  • This paper evaluates the seismic response of three dimensional steel space buildings using the spread plastic hinge approach. A numerical study was carried out in which a sample steel space building was selected for pushover analysis and incremental nonlinear dynamic time history analysis. For the nonlinear analysis, three earthquake acceleration records were selected to ensure compatibility with the design spectrum defined in the Turkish Earthquake Code. The interstorey drift, capacity curve, maximum responses and dynamic pushover curves of the building were obtained. The analysis results were compared and good correlation was obtained between the idealized dynamic analyses envelopes with and static pushover curves for the selected building. As a result to more accurately account response of steel buildings, dynamic pushover envelopes can be obtained and compared with static pushover curve of the building.

Dynamic simulation models for seismic behavior of soil systems - Part I: Block diagrams

  • Sahin, Abdurrahman
    • Geomechanics and Engineering
    • /
    • 제9권2호
    • /
    • pp.145-167
    • /
    • 2015
  • Digital simulation has recently become the preferred method for designing complex and dynamic systems. Simulation packages provide interactive, block-diagram environment for modeling and simulating dynamic models. The block diagrams in simulation models are flowcharts which describe the components of dynamic systems and their interaction. This paper is the first part of the study for determining the seismic behavior of soil systems. The aim of this part is to present the constructed block diagrams for discrete-time analysis of seismic site amplification in layered media for vertically propagating shear waves. Detailed block diagrams are constructed for single and multiple soil layers by considering wave propagation with and without damping, respectively. The block diagrams for recursive filter to model attenuation in discrete-time form are also constructed. Finite difference method is used for strain calculation. The block diagrams are developed by utilizing Simulink which is a software add-on to Matlab.

원자력발전소용 주 제어반의 내진 검증 (Seismic Qualification of the Main Control Board for Nuclear Power Plant)

  • 변훈석;이준근
    • 한국소음진동공학회논문집
    • /
    • 제12권11호
    • /
    • pp.856-863
    • /
    • 2002
  • Seismic qualification of the main control board(MCB) for the nuclear power plant Ulchin 5 and 6 has been performed with the guideline of ASME Section III and IEEE 344 code. As the size and weight of the MCB are too large and heavy to excite using the excitation table, finite element analysis is used in order to investigate the dynamic behaviors and structural integrity of the MCB. As the fundamental frequencies of the equipment are found to be less than 33 Hz, which is the upper frequency limit for the dynamic analysis, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the electrical stability of the major components of the MCB. modal analysis theory has been adopted to derive the required response spectra at the component locations. As the all combined stresses obtained from the above procedures are less than the allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors can confirm the safety of the nuclear equipment MCB under the given seismic loading conditions.