• Title/Summary/Keyword: Dynamic SPME

Search Result 7, Processing Time 0.026 seconds

Analysis of Volatile Fatty Acids in Air by Dynamic SPME (Dynamic SPME를 이용한 공기 중 지방산 분석)

  • Yu, Mee-Seon;Yang, Sung-Bong;Ha, Nam-Ki
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

Comparisons of Volatile Compounds Extracted from Pinus densiflora by Headspace Analysis (Headspace법에 의한 솔향의 분석)

  • 이미정;정은주;이신조;조지은;이양봉;조현종;윤정로
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.1
    • /
    • pp.26-31
    • /
    • 2002
  • Volatile compounds from three parts of needles, sprouts and twigs in Pinus densiflora were extracted by solid phase microextraction (SPME) and dynamic headspace analysis (DHA). separated by gas chromatography, and identified by using mass selective detecter and Kovat's retention index. The amounts of monoterpenes isolated by SPME and DHA were 66.7% and 14.3% in needles, 90.6% and 0.7% in sprouts, and 90.6% and 1.2% in twings, respectively. The amounts of sesquiterpenes detected only by SPME were 25.8% in needles, 4.4% in twings and 1.5% in sprouts. And the amounts of oxygenated terpenes isolated by SPME and DHA were 4.7% and 79.0% in sprouts, 3.7% and 70.4% in twigs, and 1.0% and 50.7% in needles, respectively. The kinds of volatile compounds isolated by SPME were similar to those by solvent extraction, but the number of compounds identified to hate a boiling point below 5$0^{\circ}C$ by UHA was larger than that of SPME.

The Evaluation of Solid-Phase Microextraction(SPME) Techniques for Analyzing Mixed Fuel Oxygenates and Products

  • 이재선;이시진;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.458-461
    • /
    • 2003
  • Solid-phase microextraction (SPME) and gas chromatography/headspace techniques(HS) and flame ionization detection (GC/FID) have been combined for determination of very polar compounds in water, including the widely used gasoline oxygenates and by-products. A relatively simple extraction method using a CAR/PDMS(75${\mu}{\textrm}{m}$) SPME fiber was optimized for the routine analysis of gasoline oxygenates and by-products in groundwater and reagent water. A sodium chloride concentration of 25%(w/w) combined with an extraction time of 20 min provided the greatest sensitivity while maintaining analytical efficiency Replicate analyses in fortified reagent and groundwater spiked with microgram per liter concentrations of gasoline oxygenates and by-products indicate quantitative and reproducible recovery of these and related oxygenate compounds. Method dynamic range was 50$\mu\textrm{g}$ L-1 to 3000$\mu\textrm{g}$ L-1 for gasoline oxygenates and by-products.

  • PDF

Analysis of VOCs emitted from the Annals of the Joseon Dynasty by Dynamic Chamber System (Chamber System을 이용한 조선왕조실록의 미세유출가스 분석)

  • Kang, Yeong-Seok;Seo, Jin-Ho
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.9-16
    • /
    • 2010
  • The Annals of the Joseon Dynasty is one of the World Heritage which should be conserved well. However, some of wax treated volume of the Annals of the Joseon Dynasty have damaged seriously. Currently a variety of efforts to conserve and restore the injured volumes are continued and many studies about the aging mechanism of the wax treated volume have being progressed. The analysis of VOCs (Volatile Organic Compounds) emitted from paper cultural heritage is one of the methods to understand the degradation pathway of paper cultural heritage. The analysis of VOCs emitted from paper cultural heritage has been mainly conducted by SPME (Solid Phase Microextraction) method. SPME is potable and simple method but it is difficult to collect all VOCs emitted from a book such as the Annals of Joseon Dynasty. The dynamic chamber system has generally used to do analysis of VOCs emitted from the building materials, furniture and electric appliances. The chamber system is possible to do quantitative and qualitative analysis by a continuous $N_2$ gas flow and the proper chamber which is able to gather all VOCs emitted from the Annals of the Joseon Dynasty. In this study, the most material among detected VOCs was Naphthalene. Naphthalene has used to prevent organic cultural heritage from being damaged by various microbes for a long time. Apart from Naphthalene, main VOCs were Acetic acid, 2-Chloroethanol, 2-Bromoethanol, Furfural, 1-Methylnaphthalene, Azulene, and 2,4-Dioctylphenol. Of these VOCs, Furfural especially was known for a marker which represents a different emission rate according to the aging level.

  • PDF

Determination of Aroma Components in Pinus densiflora (Pine Needles) Studied by Using Different Extraction Methods (추출방법에 따른 솔잎의 휘발성 성분 조성 비교)

  • Lee Jae-Gon;Lee Chang-Gook;Baek Shin;Kwon Young-Ju;Jang Hee-Jin;Kwag Jae-Jin;Rhee Moon-Soo;Lee Gae-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.2
    • /
    • pp.161-168
    • /
    • 2006
  • The efficiency of six different extraction methods for the analysis of aroma components from pine needle(P. densiflora) was compared by gas chromatography-mass selective detector(GC-MSD). The six methods were dynamic headspace(DHS), reduced pressure headspace(RPHS), solid-phase microextraction(SPME), simultaneous distillation-extraction(SDE), supercritical fluid extraction(SFE) and pyrolysis distillation extraction(PDE). A total of 65 compounds were identified by using the six different extraction methods. These compounds are classified into six categories in terms of chemical functionality: 25 hydrocarbons, 16 alcohols, 9 carbonyls, 6 esters, 7 acids, and 2 ethers. The aroma compounds having low boiling point were more abundant in DHS, RPHS, and SPME extracts. On the other hand, the aroma compounds having high boiling point were more abundants in SDE, SFE and PDE extracts. The acid compounds were extracted by heat-based extraction methods such as SDE, SFE, PDE, but not by DHS, RPHS and SPME, which used neither solvent nor heat. The oxygenated terpens, hexanal, hexanol, and hexadienal were more abundant in DHS and RPHS extracts, compared with the other methods.

A Study on the Analytical Methods Using Solid-phase Extraction for the Determination of Phenols in Water

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.135-138
    • /
    • 2003
  • Based on solid phase extraction, gas chromatography and mass spectrometry procedure for determining phenol and its derivatives in natural water was presented. In solid phase extraction, three types of techniques using solid phase adsorption material were treated with acid and salt, and converted second portion of acetyl derivatives. Under the these condition, extraction efficiency and detection ability dependent on extraction methods were discussed. Obtained results using optimized solid phase extraction techniques showed more convenience, simplifier and lower cost than the conventional analytical methods with holding wide dynamic range and lower detection limits.

  • PDF