• 제목/요약/키워드: Dynamic Power Distribution Control

검색결과 108건 처리시간 0.036초

통합 열관리 시스템의 제어를 위한 수소-전기 하이브리드 기반 고정밀 소형 선박 시뮬레이터 모델 개발 (Development of a High-precision Small Ship Simulator Model Based on Hydrogen-electric Hybrid to Control an Integrated Thermal Management System)

  • 안민우;현대일;한재영
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.230-239
    • /
    • 2024
  • Efforts are being made to replace ship diesel engines with electric propulsion motors in response to emission regulations. In particular, in the case of short-range small ships, research is being conducted to replace polymer electrolyte membrane fuel cells (PEMFC) with power sources. However, PEMFC has problems such as slow dynamic response characteristics and reduced durability at high temperatures. To solve this problem, a high-precision ship model was developed with power distribution and thermal management strategies applied, and through this, the required power, heat, and power characteristics of the propulsion system according to the ship's speed profile were analyzed.

Model Predictive Control of Bidirectional AC-DC Converter for Energy Storage System

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.165-175
    • /
    • 2015
  • Energy storage system has been widely applied in power distribution sectors as well as in renewable energy sources to ensure uninterruptible power supply. This paper presents a model predictive algorithm to control a bidirectional AC-DC converter, which is used in an energy storage system for power transferring between the three-phase AC voltage supply and energy storage devices. This model predictive control (MPC) algorithm utilizes the discrete behavior of the converter and predicts the future variables of the system by defining cost functions for all possible switching states. Subsequently, the switching state that corresponds to the minimum cost function is selected for the next sampling period for firing the switches of the AC-DC converter. The proposed model predictive control scheme of the AC-DC converter allows bidirectional power flow with instantaneous mode change capability and fast dynamic response. The performance of the MPC controlled bidirectional AC-DC converter is simulated with MATLAB/Simulink(R) and further verified with 3.0kW experimental prototypes. Both the simulation and experimental results show that, the AC-DC converter is operated with unity power factor, acceptable THD (3.3% during rectifier mode and 3.5% during inverter mode) level of AC current and very low DC voltage ripple. Moreover, an efficiency comparison is performed between the proposed MPC and conventional VOC-based PWM controller of the bidirectional AC-DC converter which ensures the effectiveness of MPC controller.

동적 부하를 고려한 계측 축중의 신뢰 범위 (Confidence bevels of Measured Axle Load with a Consideration of Dynamic Loading)

  • 조일수;김성욱;이주형;박종연;이동훈;조동일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.303-303
    • /
    • 2000
  • It is difficult to determine the static axle weight of a vehicle with weigh-in-motion systems which in absence measure instantaneous axle impact forces. The difficulty in determining a static axle weight results from dynamic effects induced by vehicle/road interactions. One method to improve the problem is to quantify a statistical confidence level for measured axle weight. The quarter-car model is used to simulate vehicle motion, Also, the road input to vehicle model can be characterized in statistical terms by PSD (power spectral density) of appropriate amplitude and frequency contents other than an exact spatial distribution. The confidence levels for the measured axle weight can be obtained by the random process analysis using both vehicle model and road input.

  • PDF

New algorithm for simulating heat transfer in a complex CPFS (Cable Penetration Fire Stop)

  • Yun, Jong-Pil;Kwon, Seong-Pil;Cho, Jae-Kyu;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1798-1803
    • /
    • 2003
  • In this work the dynamic heat transfer occurring in a cable penetration fire stop system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealants. The dynamic heat transfer can be described by a partial differential equation (PDE) and its initial and boundary conditions. For the shake of simplicity PDE is divided into two parts; one corresponding to the heat transfer in the axial direction and the other corresponding to the heat transfer on the vertical layers. Two numerical methods, SOR (Sequential Over-Relaxation) and FEM (Finite Element Method), are implemented to solve these equations respectively. The axial line is discretized, and SOR is applied. Similarly, all the layers are separated into finite elements, where the time and spatial functions are assumed to be of orthogonal collocation state at each element. The heat fluxes on the layers are calculated by FEM. It is shown that the penetration cable influences the temperature distribution of the fire stop system very significantly. The simulation results are shown in the three-dimensional graphics for the understanding of the transient temperature distribution in the fire stop system.

  • PDF

보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의 (A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding)

  • 곽주식;심정운;심응보;최종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

자기연성을 이용한 동극형 자기베어링의 고장강건 제어 (Fault Tolerant Homopolar Magnetic Bearings with Flux Coupling)

  • 나언주
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.83-92
    • /
    • 2008
  • This paper develops the theory for a fault-tolerant, permanent magnet biased, homopolar magnetic bearing. If some of the coils or power amplifiers suddenly fail, the remaining coil currents change via a novel distribution matrix such that the same magnetic forces are maintained before and after failure. Lagrange multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrix that maximizes the load capacity of the failed bearing. Some numerical examples of distribution matrices are provided to illustrate the theory. Simulations show that very much the same dynamic responses (orbits or displacements) are maintained throughout failure events (up to any combination of 3 coils failed for the 6 pole magnetic bearing) while currents and fluxes change significantly. The overall load capacity of the bearing actuator is reduced as coils fail. The same magnetic forces are then preserved up to the load capacity of the failed.

조건부스펙트럼을 적용한 원전 격납건물의 비선형 동적 해석 기반 지진취약도평가 (Application of Conditional Spectra to Seismic Fragility Assessment for an NPP Containment Building based on Nonlinear Dynamic Analysis)

  • 신동현;박지훈;전성하
    • 한국지진공학회논문집
    • /
    • 제25권4호
    • /
    • pp.179-189
    • /
    • 2021
  • Conditional spectra (CS) are applied to the seismic fragility assessment of a nuclear power plant (NPP) containment building for comparison with a relevant conventional uniform hazard response spectrum (UHRS). Three different control frequencies are considered in developing conditional spectra. The contribution of diverse magnitudes and epicentral distances is identified from deaggregation for the UHRS at a control frequency and incorporated into the conditional spectra. A total of 30 ground motion records are selected and scaled to simulate the probability distribution of each conditional spectra, respectively. A set of lumped mass stick models for the containment building are built considering nonlinear bending and shear deformation and uncertainty in modeling parameters using the Latin hypercube sampling technique. Incremental dynamic analysis is conducted for different seismic input models in order to estimate seismic fragility functions. The seismic fragility functions and high confidence of low probability of failure (HCLPF) are calculated for different seismic input models and analyzed comparatively.

SVM 기반 히스테리시스 제어기를 이용한 D-STATCOM 전류 제어에 관한 연구 (A Study on Current Control using a Novel SVM-Based Hysteresis Controller in D-STATCOM)

  • 최정혜;신은철;유지윤
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.293-301
    • /
    • 2006
  • 배전급 STATCOM(Distribution-network STATic synchronous COMpensator)에 적용 가능한 공간 벡터 변조 (Space Vector Modulation, SVM) 기법을 이용한 히스테리시스 전류제어기를 제안하였다. 히스테리시스 전류제어기는 빠른 응답 특성, 쉬운 구현, 파라미터 변화에 대한 둔감성 등 많은 장점에도 불구하고 높은 스위칭 주파수와 제한되지 않는 전류 오차 때문에 스위칭 주파수에 영향을 받는 배전급 STATCOM 전류제어기로는 적합하지 않았다. 또한 전압 벡터의 인가방식에서도 뚜렷한 근거가 없어 전류오차가 제한되지 않았다. 이에 본 논문에서는 구역판별기, SVM, 그리고 외부와 내부 히스테리시스 제어기를 이용하여 높은 스위칭 주파수를 저감하고 특정 밴드 내에서 전류 오차를 줄인 개선된 SVM 기반의 히스테리시스 전류제어기를 제안하고 모의실험을 통해 제안한 기법의 유효성을 입증하였다.

배전운영시스템용 응용 프로그램을 위한 공통 데이터베이스 구축 (Development of Common Database for the Application Programs of Distribution Management System)

  • 윤상윤;추철민;권성철;이학주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1199-1208
    • /
    • 2013
  • In recent years, the development of application programs for distribution system analysis and control has been essential part for distribution management system (DMS). In this paper, we propose the common database for application programs of distribution management system. The proposed database model has several characteristics as followings. First, the proposed database model is designed for the common use of almost the whole distribution application software. The static equipment model and dynamic type tables are mixed and the parallel table structure is applied. Second, the linked list structure of database are used for the fast processing of applications. The database model includes the hierarchy and non-hierarchy distribution system structure. Third, the reduction method of distribution database is applied. For this, we present the network reduction rules. The basic concept of reduction rules are the electrical unification of successive line section which has not lateral branches and the removal of simple lateral branches which has no devices and other laterals. Proposed database model is tested for the Jeju system of Korea Electric Power Corporation (KEPCO). Through the test, we verified that the proposed database structure can be effectively used to accomplish the distribution system operation.

PMSG 풍력발전시스템에서 전원 저전압 발생시 비틀림 진동 동특성 시뮬레이션 (Simulation of Dynamic Torsional Vibration during Grid Low Voltage in a PMSG Wind Power Generation System)

  • 권순형;송승호;최주엽;정승기;최익
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.242-244
    • /
    • 2011
  • A wind generator system model includes wind model, rotor dynamics, synchronous generator, power converter, distribution line and infinite bus. This paper investigates the low-Voltage Ride-Through capability of PMSG wind turbine in a variable speed. The drive train of a wind turbine on 2-mass modeling can observe the shaft torsional vibration when the low-voltage occur. To reduce the torsional vibration when the low-voltage occur, this paper designs suppression control algorithm of the torsional vibration and implements simulation. A Matlab/Simulink is used to investigate the response during the transient state.

  • PDF