슬라이더의 동적거동에 대한 실험적 고찰(DFHT를 이용한 슬라이더의 동적거동 측정 방법) (Experimental study of dynamic response of a slider(A Measurement of Slider Dynamic Using DFHT))

  • 강태식;김재원;박노열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1117-1121
    • /
    • 2001
  • The dynamic behavior of slider is investigated using Dynamic Flying Height Tester(DFHT). The dependence of slider's dynamic fluctuation on disk velocity is measured, and a comparison is made with the computational result.

  • PDF

손등피부의 운동마찰계수 획득을 위한 컨트롤 요소 및 측정에 관한 연구 (A Study on Quality Control and Measurement for Acquisition of Dynamic Friction Coefficient on Back-hand Skin)

  • 이재훈;송한욱;박연규;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.103-111
    • /
    • 2008
  • Recently, skin diagnosis has been suggested as a promising tool for discrimination of Sasang Constitution, reported by examining the skin characteristics such as thickness, stiffness, slip, and skin textures like wrinkles and furrows. However, the works had a limitation in that clinical decision on the skin characteristics was made by relying upon oriental medicine doctors' subjective sense of touch. In order to objectify the skin diagnosis and claim its efficacy on the discrimination of the Sasang Constitutions, it is necessary to demonstrate its discrimination capability by providing numerical values in terms of physical quantities obtained from measurements using today's sensors and equipment technologies, which motivated this work as a priliminary step towards objectification of skin diagnosis. The skin characteristics focused in this work is the slip property of the back-hand skin that has been exploited using the dynamic friction measurement system. First, curved geometric effects of the back-hand skin on the measured lateral/vertical force signals were estimated using the artificially designed silicon coated structures, which led to a suggestion on a quality controlled experimental design based upon a empirical analysis model. Second, the experimental design thus suggested has been applied to the measurement of dynamic friction coefficients for two healthy male subjects of Taeumin (TE) and Soyangin (SY), respectively. The result shows that the dynamic friction coefficient is less for the SY subject than for the TE subject around the area of the skin used for diagnosis by the oriental medicine doctor, implying the TE subject's skin is more slippery than the SE subject's that is consistent with the oriental medicine doctor's diagnosis. Hopefully, this work can provide guidelines for obtaining quality data in friction measurement to be collected for discussion on the efficacy of the skin diagnosis and its objectification through statistical analysis.

  • PDF

비마커 영상기반 변위계측 시스템을 이용한 구조물의 동특성 측정 (Measurement of Dynamic Characteristics on Structure using Non-marker Vision-based Displacement Measurement System)

  • 최인섭;김준희
    • 한국전산구조공학회논문집
    • /
    • 제29권4호
    • /
    • pp.301-308
    • /
    • 2016
  • 본 연구에서는 마커없이 구조물의 변위를 측정할 수 있는 영상기반 변위계측 시스템(NVDMS)을 제안한다. 기존의 방식과 제안하는 NVDMS는 크게 두 가지의 차이점이 있다. 첫째, NVDMS는 마커를 사용하지 않고 구조물의 특징점의 픽셀좌표 변화를 추출한다. 둘째, 특징점의 픽셀좌표를 물리좌표로 변환하는 scaling factor는 기존 방식에선 마커의 크기로부터 계산되는 반면, NVDMS에서는 카메라와 구조물사이의 거리, 각도, 초점거리로 계산된다. 3층 축소모형의 자유진동 실험에서 제안한 NVDMS로부터 얻은 변위데이터의 신뢰도를 분석하기 위해 LDS로부터 얻은 변위데이터의 비교를 하였으며, 얻어진 변위데이터를 이용하여 동특성을 분석하였다. 분석결과 NVDMS는 마커없이 구조물의 동적변위를 정밀하게 측정가능할 뿐만 아니라 얻어진 변위데이터로부터 추출한 동특성의 신뢰도 또한 높았다.

다이나믹 프로그래밍 기반 경동맥 내막-중막 두께 자동측정 시스템 (Automated Measurement System of Carotid Artery Intima-Media Thickness based on Dynamic Programming)

  • 이유부;김명희
    • 한국시뮬레이션학회논문지
    • /
    • 제16권1호
    • /
    • pp.21-29
    • /
    • 2007
  • 본 연구에서는 경동맥 B-모드 초음파영상에서 내막-중막 두께(IMT : Intima-Media Thickness)의 자동측정을 위해 다이나믹 프로그래밍(dynamic programming)을 이용하여 내막과 중막의 경계선을 자동 추출하는 알고리즘을 제안하고 실험결과를 보여준다. 혈관 인터페이스의 픽셀 값과 기울기 등의 영상특징과 연속성의 기하학적 특징을 고려한 평가항(cost term)들을 포함하는 평가함수(cost function)를 계산하여 그 값이 최소가 되는 최적의 위치를 결정하기 위해 다이나믹 프로그래밍 방법을 적용하였다. 또한 스페클(speckle), 드랍아웃(dropout)과 같은 잡음과 약한 에지로 인한 거친 추출 결과에 대해 B-spline을 적용하여 더욱 부드러운 경계선을 유지하도록 함으로써 경계선의 연속성을 향상시켰다. 제안한 방법은 다중영상특징(multiple image features)을 고려함으로써 일반적인 에지 알고리즘보다 더욱 정확하고 재생산 가능한 경계선을 추출하였고 수동측정 시 발생하는 측정자 내, 측정자 간의 추출결과 변이성과 비효율성의 문제점을 해결하여 편리한 자동측정이 가능하게 한다.

  • PDF

항공기의 롤운동 동안정미계수 측정에 관한 연구 (A Study on the Measurement of Dynamic Stability Derivatives in the Rolling Motion of Aircraft)

  • 조환기
    • 한국항공운항학회지
    • /
    • 제21권4호
    • /
    • pp.41-46
    • /
    • 2013
  • 본 논문은 항공기의 롤운동에 대한 동안정미계수 측정을 위한 실험적 기법에 관하여 기술하였다. 항공기 동안정미계수의 실험적인 추출 방법은 항공기 모델을 이용하여 풍동에서 진동실험을 수행하는 것이다. 항공기 모델의 진동은 강제진동기법이 적용되었다. 강제진동 기법은 항공기 모델의 내부에 밸런스형의 측정장치를 설치하고 모델을 풍동 시험부 내에 고정한 후에 강제로 진동시키면서 밸런스로부터 측정값을 획득하는 방법이다. 롤링 운동에 대한 동안정미계수는 풍속이 있는 상태에서 강제진동에 의한 항공기 모델의 모멘트와 진동 주파수 및 진폭을 측정한 후에 자료처리를 통하여 계산되었다. 풍동실험의 결과는 타 기관에서 측정된 표준동역학모델의 롤 동안정미계수와 유사한 결과가 얻어짐을 확인하였다.

초고속 회전체용 공기 포일 베어링의 동특성 계수 측정을 위한 전자석 가진장치에 관한 연구 (Study on the Electromagnetic Excitation System for the Measurement of Dynamic Coefficients of Air Foil Bearing for High Speed Rotor)

  • 박철훈;최상규;함상용
    • 한국유체기계학회 논문집
    • /
    • 제16권3호
    • /
    • pp.18-25
    • /
    • 2013
  • Recently the requirement of long-term mobile energy source for mobile robot or small-sized unmanned vehicle is highly increased, and the micro turbine generator(MTG) which is known to have high energy and power density is under development. MTG is designed to have air foil bearing and high speed rotor of which operating speed is 400,000rpm. In the development stage of high speed rotor and bearing, stability analysis for the full operational speed range is essential and the dynamic coefficients such as stiffness and damping coefficients of bearing depending on the rotational speed are required for that. Although perturbation method is usually used to identify the dynamic coefficients, it's not easy to give the perturbation to the high speed rotating rotor. In this study, we present the dynamic coefficients measurement system for air foil bearing which consists of electromagnets, gap sensors, high speed motor and controller. This measurement system can exert the sine sweep force to the rotor-bearing, measure the displacement of rotor and get FRF(Frequency response function) of rotor-bearing. The least square estimation method is applied to identify the dynamic coefficients of bearing from the measured frequency response at the different rpm and the identified dynamic coefficients for the wide rotational speed range are presented.

비특이성 만성 경부통 환자에게 적용한 동적 균형 운동이 통증과 기능적 수준, 심리사회적 수준에 미치는 효과 (Effects of Dynamic Balance Exercise on Pain, Functional level, and Psychosocial Level in Patients with Non-specific Chronic Neck Pain)

  • 권유희;김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제29권3호
    • /
    • pp.43-53
    • /
    • 2023
  • Background: Patients with neck pain develop instability due to muscle imbalance, decreased proprioception, and balance disorders. Studies have examined various exercise methods as treatment methods, but few studies have compared the effects of cervical stabilization exercise and dynamic balance exercise. The purpose of this study was to investigate the effects of dynamic balance exercise on pain, functional level, and psychosocial level in patients with non-specific chronic neck pain. Methods: Thirty-four non-specific chronic neck pain patients were randomly assigned to the experimental group (EG, n=17) and control group (CG, n=17); the cervical stabilization exercise and dynamic balance exercise program were applied to the EG; and only the cervical stabilization exercise program was applied to the CG. The intervention was conducted twice a week, for six weeks. Assessment items evaluated pain, dysfunction (Korean version neck disability index), range of motion, craniocervical flexion test, cervical deep flexor endurance test, and psychosocial level. Data analysis was performed using intention-to-treat analysis as assigned. To analyze differences in the items assessed in the two groups, we used a repeated measures analysis of variance with an interaction between group (EG, CG) and time point (baseline, 6 weeks, 12 weeks). Results: The endurance of the cervical flexor muscles between the group and the measurement point after intervention (p<.05). Both groups showed significantly improved endurance between time points after the intervention (p<.05), with the EG showing a greater change than the CG. None of the other measurement items differed in the pattern of change between measurement points. Conclusion: In conclusion, the EG applying a cervical stabilization exercise and a dynamic balance exercise experienced a significant difference in muscle endurance improvement compared to the CG. We propose an exercise intervention program that includes stabilization exercises and dynamic balance exercises for patients with chronic cervical pain who lack muscle endurance.

  • PDF

화상회의 시스템에서 RSTT를 이용한 동적 흐름제어 기법에 관한 연구 (The Study of Dynamic Flow Control Method using RSST in Video Conference System)

  • 구하성;심종익
    • 한국정보통신학회논문지
    • /
    • 제9권8호
    • /
    • pp.1683-1690
    • /
    • 2005
  • 본 논문에서는 UDP에서의 동적 흐름 제어기법을 제안하며, 기존의 동적 흐름제어에서 많이 사용되는 측정 요소인 패킷 손실과 왕복시간의 특성에 대해 분석한 후 새로운 측정요소인 RSTT를 제안한다. 제안된 RSTT를 사용한 알고리즘은 전송률을 조절하는데 있어서 현재 측정된 네트워크 상태와 과거의 상태를 고려함으로써 보다 정확한 네트워크 상태측정을 할 수 있었다. 비교실험을 위하여 전송량과 네트워크의 상태를 출력하고 네트워크의 흐름패턴에 대한 상세 정보를 보여주는 네트워크 상태측정 프로그램을 구현하였다. 이를 이용한 성능실험을 통해 제안된 알고리듬이 기존 알고리듬에 비해 낮은 패킷 손실률로 네트워크 상태에 더욱 빠르게 적응함을 보여준다.

Digital Image Correlation기법을 이용한 구조물의 다중 동적변위응답 측정 (Multi-point Dynamic Displacement Measurements of Structures Using Digital Image Correlation Technique)

  • 김성완;김남식
    • 한국지진공학회논문집
    • /
    • 제13권3호
    • /
    • pp.11-19
    • /
    • 2009
  • 최근 대형구조물의 유지관리에 대한 관심이 커지고 있으며 자연재해, 구조물의 노후 등으로 구조적 안전성의 검토가 요구되는 대형구조물의 수가 급증하고 있는 실정이다. 실제 사용하고 있는 구조물의 구조적 특성은 최초 설계 당시의 특성과 차이점을 보이는 것이 일반적이며 부재의 균열 및 구조물의 노후화 등으로 인한 강성저하에 의하여 구조물의 동특성에 변화가 나타날 수 있다. 구조물의 동특성의 변화를 관찰하면 손상의 위치를 파악할 수 있으며 정량적 평가 또한 가능하다. 교량, 건물 등 구조물 모니터링에 사용되는 대표적 계측장비가 동적계측기이다. 현재 구조용 동적계측기는 각 센서와 계측기를 1:1로 연결하는 방식을 취하고 있어 많은 케이블 작업을 필요로 하기 때문에 센서를 부착하지 않고 원거리에서 진동을 측정하는 방법이 필요하다. 구조물의 동적응답 계측을 위하여 적용 가능한 비접촉식 방법으로는 레이저의 도플러효과 및 GPS를 이용하는 방법 등이 있으나 비경제적이기 때문에 교량구조물에 적용하기에 보편적이지 못하다. 그러나 영상 이미지를 이용하는 방법은 경제적이며 접근이 어려운 구조물의 진동 및 동특성 추출에 적합하다. 기존에 도 센서를 대신하여 카메라의 영상신호를 이용하는 연구가 수행되었으나 구조물에 부착된 target의 한 지점을 기록한 후 이미지 처리기법 을 이용하여 변위응답을 측정하는 방법으로서 측정 대상이 비교적 국한적일 수 있다. 그러므로 본 연구에서 제안한 DIC(Digital Image Correlation)기법을 이용한 다중 변위응답 측정기법을 검증하기 위하여 실내모형실험을 수행하였다.

Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

  • Jeong Bin Park;Yeon Joo Jeong;Geewon Lee;Nam Kyung Lee;Jin You Kim;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.94-101
    • /
    • 2019
  • Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50-120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.