• 제목/요약/키워드: Dynamic Measurement

검색결과 1,876건 처리시간 0.031초

Dynamic Magnetic Field Measurement in the Air Gap of Magnetic Bearings Based on FBG-GMM Sensor

  • Jiayi, Liu;Zude, Zhou;Guoping, Ding;Huaqiang, Wang
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.575-585
    • /
    • 2015
  • Magnetic field in magnetic bearings is the physical medium to realize magnetic levitation, the distribution of the magnetic field determines the operating performance of magnetic bearings. In this paper, a thin-slice Fiber Bragg Grating-Giant Magnetostrictive Material magnetic sensor used for the air gap of magnetic bearings was proposed and tested in the condition of dynamic magnetic field. The static property of the sensor was calibrated and a polynomial curve was fitted to describe the performance of the sensor. Measurement of dynamic magnetic field with different frequencies in magnetic bearings was implemented. Comparing with the finite element simulations, the results showed the DC component of the magnetic field was detected by the sensor and error was less than 5.87%.

In-vivo 피부의 동적 점탄성 측정 (Measurement of Dynamic Viscoelasticity of In-vivo Human Skin)

  • 권현준;권영하;정철곤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.525-526
    • /
    • 2006
  • The products designed by human sensibility and ergonomics are given good impression. Especially the touch feeling on the human skin is very useful sensibility for quality of products. Elasticity and viscosity of human skin is very important element in product design based on ergonomics. In this paper, we describe a sophisticated method for measurement of dynamic viscoelasticity characteristics of human skin. For this measurement, we developed a measurement system assembled with load cell, actuator, amplifier and data acquisition system. The $MATLAB^{TM}$ is used to analyze the data and fit a approximation curves.

  • PDF

철도구조물 진동계측에의 고정밀 디지털 데이터로거 적용성 연구 (A Study of Dynamic Measurement using High Accuracy Digital Datalogger System for Railway Structures)

  • 이승원;이근호;정재민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1006-1011
    • /
    • 2008
  • The objective of this study is the developement of real time automatic dynamic measurement using high accuracy digital datalogger for safety and maintence of railway construction sites. For the replacement of current 16 bit analog/digital converter, Digital datalogger system using 24 bit analog/digital converter is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the automatic high accuracy digital datalogger system. The results of this study will be using real time automatic dynamic measurement of railway structures.

  • PDF

Health Monitoring of High-rise Building with Fiber Optic Sensor (SOFO)

  • Mikami, Takao;Nishizawa, Takao
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.27-37
    • /
    • 2015
  • Structural health monitoring is becoming more and more important in the domain of civil engineering as a proper mean to increase and maintain the safety, especially in the land of earthquakes like Japan. In many civil structures, the deformations are the most relevant parameter to be monitored. In this context, a monitoring technology based on the use of long-gage fiber optic deformation sensor, SOFO is being applied to a 33-floors tall building in Tokyo. Sensors were installed on the $2^{nd}$ floor's steel columns of the building on May 2005 in the early stage of the construction. The installed SOFO sensors were dynamic compatible ones which enable both static and dynamic measurements. The monitoring is to be performed during the whole lifespan of the building. During the construction, static deformations of the columns had been measured on a regular basis using a reading unit for static measurement and dynamic deformation measurements were occasionally conducted using a reading unit for dynamic measurement. The building was completed on August 2006. After the completion, static and dynamic deformation measurements have been continuing. This paper describes a health monitoring technology, SOFO system which is applicable to high-rise buildings and monitoring results of a 33-floors tall building in Tokyo from May 2005 to October 2010.

실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가 (Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing)

  • 류성룡;정창헌;조현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • 제8권4호
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

Effect of Passive Temperature Therapy of the Femoral Muscles on the Countermovement Jump Performance

  • Lee, Jintaek;Panday, Siddhartha Bikram;Byun, Kyungseok;Lee, Jusung;Hwang, Jinny;Moon, Jeheon
    • 한국운동역학회지
    • /
    • 제29권4호
    • /
    • pp.227-235
    • /
    • 2019
  • Objective: The purpose of this study was to evaluate the effect of passive-acute temperature therapy of the femoral muscle and dynamic warm-up on the countermovement jump performance. Method: Twenty male track and field athletes from national team underwent three treatments applied on the femoral muscles; cold temperature treatment, thermal treatment and dynamic warm-up. The variables extracted at 2 time points (pre-measurement and post measurement) were the temperature of the left and right femoral muscle, displacement & velocity of centre of mass, peak power out, range of motion and moment & power of the knee joint. Results: There was a statistically significant difference in the temperature of the femoral muscle according to measurement time which was high in the order of thermal treatment, dynamic treatment and cold treatment. The jump height was the highest in the dynamic warm-up with no statistically significant difference for the range of motion of the knee joint. The peak power out at dynamic warm-up and the power of the knee joint were statistically significant according to the treatment and measurement time. Conclusion: Local cold and thermal treatment of femoral muscles at ambient temperature did not improve jump performance, while dynamic warm-up was considered to be effective for maintaining the performance of the activities that require strong muscular power.

영상처리를 이용한 정동적 변위 계측과 속도, 가속도 추산방식 연구 (Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration)

  • 허석;곽문규;이호범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.527-532
    • /
    • 2010
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, ccd image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration measurement, velocity and acceleration directly without any contact. The current resolution of the displacement measurement is limited to 1/100 millimeter scale.

  • PDF

A Study on the Cost-Effective Personalized Plantar Pressure Measurement System

  • Kang, Ji-Woo;Kwon, Young-Man;Lim, Meoung-Jae;Chung, Dong-Kun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권4호
    • /
    • pp.11-17
    • /
    • 2019
  • Plantar pressure data can be used not only for walking patterns in daily life, but also for eating, health care, and disease prevention. For this reason, the importance of plantar pressure measurement has recently increased. However, most systems that can measure both static and dynamic plantar pressure at the same time are expensive, not portable, and not universal. In this study, we propose a system that effectively reduces the number of sensors in plantar pressure system. Through this, we want to increase the economics and practicality by reducing the size and weight of the system, as well as the power consumption. First, for static plantar pressure and dynamic plantar pressure, the values measured by existing precision instruments are analyzed to determine how many measurement parts the insole is divided into. Next, for the divided measuring parts, the position of the sensor is determined by calculating the Center of Pressure (COP) for each part with the values of all dynamic and static plantar pressure sensors. Finally, in order to construct a personalized plantar pressure measurement system, we propose a weighting method for the static plantar pressure COP and the dynamic plantar pressure COP for each part.