• Title/Summary/Keyword: Dynamic Flowrate

Search Result 29, Processing Time 0.027 seconds

AN INVERSTIGATION OF THE DYNAMIC ERRORS OF THE REMOTE-INSTANTANEOUS FLOWRATE MEASUREMENT DUE TO PARAMETER CHANGES

  • Kim, Do-Tae;Yokota, Shinichi;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1712-1717
    • /
    • 1991
  • The paper describes estimation errors of unsteady flowrate measurements due to parameter changes in a quasi-remote instantaneous flowrate measurement method (abbreviate as QIFM) and an instantaneous flowrate measurement method using two points pressure measurements (abbreviate as TPFM). By introducing error performance index, the influence of parameter changes on the accuracy, and dynamic response of the estimated unsteady flowrate are evaluated. Of four parameters, the variation of the length of the pipeline and speed of sound produce large errors in the estimated unsteady flowrate during transient periods. The effect of kinematic viscosity of the working fluid(oil) is relatively insensitive in unsteady flowrate estimation.

  • PDF

An approach for remote measurement of instantaneous flowrate by making use of hydraulic pipeline dynamics

  • Yokota, Shinichi;Kim, Dotae;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.749-754
    • /
    • 1989
  • This paper describes a remote measurement method for estimating unsteady flowrate through a pipeline. By this method, instantaneous flowrate at the remote location along a pipeline (distance L) from flowmeters is measured by making use of dynamic characteristics between two cross sections of the circular pipeline. Using this method, instantaneous flowrate is accurately measured at a location where it is difficult to setup flowmeters. The estimated flowrate waveforms by the method are compared with directly measured ones by cylindrical choke-type instantaneous flowmeter. The validity of the method is established.

  • PDF

Dynamic Characteristic Analysis of KSR-III Propulsion Feeding System (KSR-III 추진기관 공급계 동특성 해석)

  • Jung, Young-Suk;Cho, In-Hyun;Jung, Tae-Kyu;Kwon, Oh-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.1008-1013
    • /
    • 2001
  • KSR-III propulsion system designed in KARI has a gas-pressurization system for propellant feeding system. This system uses a regulator for the control of the ullage pressure of propellant tank and a venturi for passive control of propellant flowrate. This system seems to be very reliable, but the flowrate of propellant varies according to the change of acceleration with the rocket flight. In this paper, dynamic characteristic of KSR-III propulsion feeding system was analyzed in flight condition. The purpose of this research is to find the variation of off ratio and propellant flowrate change for certification condition of engine reliability test.

  • PDF

Design of pressure and flowrate control systems for a supercritical extraction process (초임계 추출 공정의 압력 및 유량 제어계 구성)

  • 김원철;김홍식;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.471-475
    • /
    • 1988
  • Pressure and flowrate control systems for a supercritical extraction process are designed and analyzed. To do this, the dynamic model was first set up using the performance equations of control valves, CO2 compressor and the state equation of the supercritical fluid. Using this model, optimum pairs of manipulated and controlled variable which give least steady stat interaction are determined though the relative gain analysis.

  • PDF

A Study on Dynamic Water Quality Change for Gate Operation in Seonakdong River (서낙동강 수문 운영에 따른 동적 수질 변화 연구)

  • Kim, Jung Min;Kim, Young Do
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1401-1411
    • /
    • 2013
  • The inflow from Daejeo gate and the outflow from Noksan gate in Seonakdong river, which is a reservoir-like river with the characteristics of stagnant water, is very important for TMDLs (Total Maximum Daily Load) of Nakbon N unit watershed. However, there are very few measured data for calculating base flow. The operating data is much different from the actual measured data because the probable maximum flowrate is used for gate operation. In this study, the operating flowrate data of Daejeo and Noksan gates are compared with the monthly water quality data from Ministry of Environment monitoring station. The dynamic change of the flowrate and the water quality is also measured for the operation of Daejeo and Noksan gates. The flowrate of Seonakdong river is measured, which is affected by the gate operation, the water elevation difference of Nakdong river and Seonakdong river, and the tidal elevation. The results of this study can be used for establishing the water quality improvement measures by the optimal gate operation.

An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method (다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구)

  • Kim, Jang Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

A Study Compensation Method for Dynamic Characteristics in Electro-Hydraulic Servosystem Equipping Load Pressure Feedback Compensator (부하압력 피이드백 보상기를 장착한 전기-유압서보계의 동특성 개선에 관한 연구)

  • Kim, Jong-Kyum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.126-136
    • /
    • 1992
  • In this paper, a simple structured feedback compensation scheme for a electro-hydraulic servo system to keep the response characteristics unchanged regardless of the load variation is proposed. In electro-hydraulic servo system, servovalve is most important control element. But the relation between input corrent and output flowrate of the servovalve has properties as follows; firstly, in spite of constant input current, output flowrate decreases as load pressure increases, secondly, according to frequency response of typical servovalve, the characteristics of gain and phase shift is something like 2'nd order system. Load pressure feedback compensation method has been applied to eliminate the first influence, the second influence has been improved by phase lead compensation method. As a result of above compensation methods, regardless of variation load condition, spring and inertia load, the compensation scheme has been verified to be effective within the range of frequency less than 25Hz by static response and dynamic response in time domain and frequency domain through experiments.

  • PDF

Modeling, Control, and Optimization of Activated Sludge Processes

  • Bae, Hye-on;Kim, Bong-chul;Kim, Sung-shin;Kim, Chang-won;Kim, Sang-hyun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.1 no.1
    • /
    • pp.56-61
    • /
    • 2001
  • Activated sludge processes are broadly used in the biological wastewater treatment processes. The activated sludge processes are complex systems because of the many factors such as the variation of influent flowrate and ingredients, the complexity of biological reactions, and the various operation conditions. The main motivation o this research is to develop an intelligent control strategy for activated sludge process (ASP). ASP is a complex and nonlinear dynamic system owing to the characteristic of wastewater, the change in influent flowrate, weather conditions, and so on. The mathematical model of ASP also includes the uncertainty which is a ignored or unconsidered factor from process designers. The ASP model based on Matlabⓡ/Simulinkⓡ is developed in this paper. And the model performance is examined by IWA (International Water Association) and COST (European Cooperation in the filed of Scientific and Technical Research) data. The model tests derive steady-state results of 14 days. In this paper, fuzzy logic control approach is applied to handle DO concentrations. The fuzzy logic controller includes two inputs and one output to adjust air flowrate. The objective function for the optimization, in the implemented evolutionary strategy, is formed with focusing on improving the effluent quality and reducing the operating cost.

  • PDF

Development of the Pneumatic Servo Valve

  • Kim, Dong-Soo;Choi, Byung-Oh;Kim, Kwang-Young;Lee, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1146-1151
    • /
    • 2003
  • Pneumatic servo valve is an electro-mechanical device which change electric signals to a proper pneumatic signals, that is, flowrate and pressure. In this study, a pneumatic servo valve was designed and each simulation was conducted on any variation in the flowrate depending upon the magnetic force of the linear force motor and the displacement of the spool. And permanent magnet was used as a material for the plunger of the servo valve. Thereby, a low electrical power consumption type coil was desinged. And a modeling for the coil design was conducted by using the magnetic circuit. also, the feasibility of the modeling was verified by using a commercial magnetic field analysis program. The designed and fabrication of the spool and sleeve, position sensor, servo controller and the dynamic characteristic verified by the experiment.

  • PDF

Development of Gasoline Direct Swirl Injector (직접분사식 가솔린 선회분사기 개발에 관한 연구)

  • Park, Yong-Guk;Lee, Chung-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.78-86
    • /
    • 2001
  • The Gasoline Direct Injection(GDI) system has been highlighted due to the improvement of fuel consumption and the control of exhaust emission from gasoline engines. The GDI system includes a high injection pressure, smaller mean diameter, good spray characteristics and stability. We were interested in the development for gasoline direct swirl injector(GDSI) in which the swirler is specially designed with an incident angle. Nymerical analysis was utilized to investigate the internal flow of GDSI with a goal to determine the swirl incident angle and needle lift. Accordingly, it describes characteristics of a GDSI in which the flowrate and spray characteristics are satisfied. especially the spray tip penetration decreases, compared with other type GDI, mean diameter of droplets is from 20${\mu}{\textrm}{m}$ to 25${\mu}{\textrm}{m}$ and spray angle ranges from 64$^{\circ}$to 66$^{\circ}$.