• 제목/요약/키워드: Dynamic CT

검색결과 143건 처리시간 0.028초

Dynamic study를 이용한 선조체에서의 18F-DOPA의 분포에 대한 평가 (Evaluation about Distribution of 18F-DOPA at Striatum by Using Dynamic Study)

  • 김재일;이홍재;김진의
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.67-71
    • /
    • 2015
  • Purpose At recently, we enter into the aging society and a age-related disease is increasing. Among that, prevalence of degenerative brain disease like Parkin's disease will be increased. So, many radiopharmaceuticals is developed to diagnosis early and to evaluate the performance of therapeutic drugs. Especially $^{18}F-DOPA$ which involved at dopamine synthesis and function of storage is widely used to the diagnosis of Parkinson's disease as well as brain tumors. in the study, we will evaluate the distribution pattern of $^{18}F-DOPA$ at the striatum by using dynamic study. Materials and Methods We used Biograph Truepoint(Siemens, Germany) as PET/CT scanner, injected a $^{18}F-DOPA$ ($600{\pm}30MBq$) to patient (4men, 6women. $67{\pm}11age$) who visited our hospital from June to September, started 95min dynamic study at same time. after finishing acquisition, we reconstructed PET data with 19 frame every 5 minutes, analysed a average counts at ROI's where set at both striatums, anterior putamen, posterior putamen Results Counts in the cerebellum as the background formed a plateau after 90 minutes from the highest out rapidly reduced to 15 minutes. Counts of anterior putamen and posterior gradually increased but formed a plateau after 60min. A count ratio of Striatum to cerebellum was continuously increased up to more than 95 minutes, A count ratios of an anterior putamen to posterior one formed a plateau after 85 minutes. Conclusion The dynamic acquisition can be possible to evaluate a distribution of the $^{18}F-DOPA$ in the striatum and the VOI analysis through a dynamic acquisition and a variety of patterns. Futhermore, to make a uniformed distribution and count ratio of striatum to cerebellum, a static acquisition will have to start 90minutes later after injection.

  • PDF

Classification and visualization of primary trabecular bone in lumbar vertebrae

  • Basaruddin, Khairul Salleh;Omori, Junya;Takano, Naoki;Nakano, Takayoshi
    • Advances in biomechanics and applications
    • /
    • 제1권2호
    • /
    • pp.111-126
    • /
    • 2014
  • The microarchitecture of trabecular bone plays a significant role in mechanical strength due to its load-bearing capability. However, the complexity of trabecular microarchitecture hinders the evaluation of its morphological characteristics. We therefore propose a new classification method based on static multiscale theory and dynamic finite element method (FEM) analysis to visualize a three-dimensional (3D) trabecular network for investigating the influence of trabecular microarchitecture on load-bearing capability. This method is applied to human vertebral trabecular bone images obtained by micro-computed tomography (micro-CT) through which primary trabecular bone is successfully visualized and extracted from a highly complicated microarchitecture. The morphological features were then analyzed by viewing the percolation of load pathways in the primary trabecular bone by using the stress wave propagation method analyzed under impact loading. We demonstrate that the present method is effective for describing the morphology of trabecular bone and has the potential for morphometric measurement applications.

전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택 (Selection of mAs with Using Table Strap in Computed Tomography Scan)

  • 이용현;안형택
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

Evaluation of the Ostium in Anomalous Origin of the Right Coronary Artery with an Interarterial Course Using Dynamic Cardiac CT and Implications of Ostial Findings

  • Jin-Young Kim;Yoo Jin Hong;Kyunghwa Han;Suji Lee;Young Jin Kim;Byoung Wook Choi;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.172-179
    • /
    • 2022
  • Objective: We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. Materials and Methods: From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. Results: During a median follow-up period of 2071 days (interquartile range, 1180.5-2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. Conclusion: The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.

폐암환자에서 종격동 방사선조사 후에 발생하는 림프구 감소증 (Lymphopenia after Mediastinal Irradiation in Lung Cancer)

  • 오윤경;하철수;박희철;이승일;류소연;기근홍;전호종
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.34-40
    • /
    • 2002
  • 목적 : 방사선치료가 세포매개면역을 저하시킨다는 보고들이 있었으나 이를 방사선치료 부위 안의 혈류와 관련해서 고려되지는 않고 있다. 본 연구는 폐암의 방사선치료 후에 발생하는 백혈구 감소, 특히 림프구의 감소를 후향적으로 분석하고, 면역억제의 한 기전으로서 방사선치료 부위 안의 많은 혈액량과 동적인 혈류가 관련될 수 있는지를 알아보고자 한다. 대상 및 방법 : 34명의 폐암환자 들을 대상으로 하였으며, 방사선치료 단독군(RT군)이 10명, 방사선치료와 화학요법 병용군(RT/CT군) 16명, 화학요법 단독군(CT군)이 8명이었다. 말초혈액의 전체 백혈구수와 림프구수, 전체 백혈구수 중 림프구수의 비율(림프구 율)을 방사선치료 전중후에, 화학요법 전후에 측정하였는데 방사선치료 중에는 매 주마다 검사를 하였고, 화학요법과 방사선치료 후에는 좀 더 긴 간격으로 하였다. 환자의 특성과 병변의 특성은 세 군간에 통계적으로 유의한 차이를 보이지 않아다. 치료방법에 있어서도 RT군과 RT/CT군 사이에 총 방사선량, 분할조사선량, 치료면적, 치료용적은 통계학적으로 유의한 차이는 없었다. 방사선치료를 시행한 군(RT군, RT/CT군)과 방사선치료를 시행하지 않은 군(CT군)의 평균 추적기간은 각각 6개월과 8개월이었다. 결과 : 치료 후 전체 백혈구수의 변화는 다른 치료군 간에 의미 있는 차이는 보이지 않았다. 방사선치료를 시행한 RT군과 RT/CT군은 방사선치료 후 훨씬 낮은 림프구수와 림프구 율을 보였다. 치료 전 림프구수와 최종 림프구수 사이의 감소는 방사선치료를 시행한 군과 시행하지 않은 군간에 통계학적으로 유의한 차이를 보였다(p=0.044). 또한 림프구 율에 있어서도 치료 전과 최종 림프구 율 사이의 감소는 방사선치료를 시행한 군과 시행하지 않은 군간에 통계학적으로 유의한 차이를 보였다(p=0.037). 결론 : 림프구 감소증은 화학요법만을 시행한 경우보다 방사선치료를 시행한 경우에 더 현저하였다. 그리고 이러한 림프구 감소증이 폐암의 흉부 방사선치료 후 면역감소의 한 원인이 될 수도 있겠다. 저 선량의 방사선조사 후 림프구의 아포토시스 유도를 보여준 이전의 몇몇 연구들을 함께 생각해 볼 때, 조심스럽게 제안하고 싶은 것은 혹시 본 연구에서 보이는 림프구 감소증이 방사선조사야 내의 많은 혈액량이나 역동적인 혈류와 약간의 관련성이 있을 수도 있다는 것이다.

픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작 (duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector)

  • 전승익;이봉구
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.969-974
    • /
    • 2022
  • 디지털 엑스레이 디텍터 영상 취득에 있어 동적 범위를 최대화하고 영상지연을 최소화하기 위해서는 엑스레이 영상센서의 픽셀내 포토다이오드에 존재하는 잔류 정전기생용량을 빠르고 완전하기 제거하는 것이 매우 중요하다. 이러한 요구사항은 특히 고속 프레임과 낮은 영상지연이 필요한 산업용 2D/3D 자동화 엑스레이 검사와 의료용 CT 엑스레이 디텍터에 특별히 요구된다. 본 연구는 리셋 박막트랜지스터, 리드아웃 박막트랜지스터 그리고 포토다이오드로 픽셀이 구성된 듀오픽스TM 엑스레이 영상센서를 처음으로 제안한다. 듀오픽스TM 엑스레이 영상센서의 구동을 검증하기 위해 105 ㎛의 픽셀 사이즈, 347 mm × 430 mm의 영상영역 그리고 3300 × 4096의 픽셀 (13.5M pixels)을 갖는 듀오픽스TM 엑스레이 영상센서를 설계, 제작하여 모듈테스터와 영상취득 프로그램을 통해 영상을 취득하였다.

단계적 충격하중에 의한 암석의 동적손상메커니즘에 관한 실험적 연구 (Experimental Study on the Dynamic Damage Mechanism of Rocks Under Different Impact Loadings)

  • 조상호;조슬기;김승곤;박찬;금자승비고
    • 터널과지하공간
    • /
    • 제19권6호
    • /
    • pp.545-557
    • /
    • 2009
  • 단계별 손상에 따른 취성재료의 동적손상메커니즘을 파악하고자 국내암석을 대상으로 스플릿 홉킨슨 압력바 시스템을 이용한 단계적 충격하중실험을 수행하였다. 실험시료 내 동적손상을 평가하기 위하여 고해상도 X-ray 단층촬영 시스템을 적용하였다. 그 결과 낮은 충격하중에서는 시료 내 전반적으로 축방향 균열 즉 수직균열이 발생하지만, 충격속도가 증가함에 따라 시료와 입사바 또는 전달바와의 접촉면에 구속효과가 발생하여 입사바와의 접촉면 중심부에 균열이 사라지는 경향을 보였다. 그러나 구속력을 적게 받는 시료의 원주표면 부근에서는 박리균열을 보였다.

척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가 (Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion)

  • 김윤혁;박원만;김경수;박형균;주증우;박경우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

$^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계 (Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET)

  • 이병일;김계훈;김정영;김수진;이재성;민정준;송호천;범희승
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.194-200
    • /
    • 2007
  • 목적: $^{13}N$-암모니아는 심근혈류 측정에 유용한 방사성의 약품으로 최근 국내에 도입된 PET/CT를 이용하여 비침습적으로 정량적인 검사를 시행 할 수 있다. 이 연구에서는 $^{13}N$-암모니아를 이용한 동적 영상으로부터 얻은 심근혈류정보와 정적 영상으로부터 얻은 심근관류정보의 상관관계를 살펴봄으로써 심장핵의학 검사의 유용성을 알아보고자 하였다. 방법: 심혈관질환이 의심되어 핵의학 심근관류 검사를 시행한 12명(남 11명, 여 1명, 평균나이 $57.9{\pm}8.6$세)을 대상으로 $^{13}N$-암모니아 검사를 시행하였다. 휴식기와 부하기에서 영상획득을 위하여 $^{13}N$ 암모니아 0.3 mCi/kg를 15초간 순간주사하면서 동시에 동적영상을 6분간(5초씩 12회, 10초씩 6회, 20초씩 3회, 30초씩 6회) 획득하고 이어서 게이트 영상을 13분간 각각 획득하였다. 심근혈류의 측정은 기저부 4분절, 중간부 4분절, 그리고 심첨부로 구성된 9분절 모델을 이용하였으며, 추출한 시간-방사능곡선과 추적자 모델을 사용하여 정량화 하였다. 심근관류는 정량화 분석 소프트웨어를 사용하여 구하였다. 20분절 모델을 9분절 모델과 비교하기 위하여 최기저부 6분절은 제외하고 인접분절의 값을 평균하여 사용하였다. 결과: 심근혈류량(휴식기, 0.18-2.38 ml/min/g; 부하기, 0.4-4.95 ml/min/g)과 심근섭취율(휴식기, 22-91%; 부하기, 14-90%) 간에는 약한 상관관계가 있었으며, 휴식기 보정된 심근관류와 혈류의 상관이 부하기에서보다 더 컸다(휴식기 r=0.59, 부하기 r=0.80). 수축기 심근두꺼워짐이 좋을수록 보정된 관상동맥 혈류예비능과 심근관류 예비능이 상관관계를 보였다. 결론: $^{13}N$-암모니아를 이용한 관류값을 특성에 따라 보정하고 해석하였을 때, 동적영상에서 절대값으로 구한 심근혈류와 좋은 상관관계를 보였다. 따라서 심근관류가 심근혈류를 잘 반영하는 지표임을 보였으므로 심장질환에서의 PET-CT 검사를 유용하게 활용할 수 있을 것으로 기대한다.

취성재료의 충격파괴에 관한 연구 I

  • 양인영;정태권;정낙규;이상호
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.298-309
    • /
    • 1990
  • In this paper, a new method is suggested to analyze impulsive stresses at loading poing of concentrated impact load under certain impact conditions determined by impact velocity, stiffness of plate and mass of impact body, etc. The impulsive stresses are analyzed by using the three dimensional dynamic theory of elasticity so as to analytically clarify the generation phenomenon of cone crack at the impact fracture of fragile materials (to be discussed if the second paper). The Lagrange's plate theory and Hertz's law of contact theory are used for the analysis of impact load, and the approximate equation of impact load is suggested to analyze the impulsive stresses at the impact point to decide the ranage of impact load factor. When impact load factors are over and under 0.263, approximate equations are suggested to be F(t)=Aexp(-Bt)sinCt and F(t)=Aexp(-bt) {1-exp(Ct)} respectively. Also, the inverse Laplace transformation is done by using the F.F.T.(fast fourier transform) algorithm. And in order to clarity the validity of stress analysis method, experiments on strain fluctuation at impact point are performed on a supported square glass plate. Finally, these analytical results are shown to be in close agreement with experimental results.