• Title/Summary/Keyword: Dynamic Background

Search Result 558, Processing Time 0.022 seconds

Modeling of truncated nanocompositeconical shell structures for dynamic stability response

  • S.M.R. Allahyari;M. Shokravi;T.T. Murmy
    • Structural Engineering and Mechanics
    • /
    • v.91 no.3
    • /
    • pp.325-334
    • /
    • 2024
  • This paper deals with the dynamic buckling behavior of truncated conical shells composed of carbon nanotube composites, an important area of study in view of their very wide engineering applications in aerospace industries. In this regard, the effective material properties of the nanocomposite have been computed using the Mori-Tanaka model, which has already been established for such analyses. The motion equations ruling the structure's behavior are derived using first order shear deformation theory, Hamilton's principle, and energy method. This will provide adequate background information on its dynamic response. In an effort to probe the dynamic instability region of the structure, differential quadrature method combined with Bolotin's method will be adopted to tackle the resulting motion equations, which enables efficient and accurate analysis. This work considers the effect of various parameters in the geometrical parameters and the volume fraction of CNTs on the structure's DIR. Specifically, it became clear that increasing the volume fraction of CNTs shifted the frequency range of the DIR to higher values, indicating the significant role of nanocomposite composition regarding structure stability.

Effects of Static and Dynamic Stretching on Lumbar Lordotic Angle and Low Back Pain in University Students

  • Ga, Heayoung;Gim, Mina
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1834-1839
    • /
    • 2019
  • Background: Lumbar lordosis is a result of muscle shortening and may cause low back pain. Objective: To examine the effects of static and dynamic stretching on lumbar lordosis and low back pain in university students. Stretching is an intervention that can be applied to shortened muscles; however, very few studies have compared the effects of static and dynamic stretching on lumbar lordosis and low back pain. Design: Randomized controlled clinical trial (single-blind) Methods: The 12 selected subjects were randomly assigned static stretching and dynamic stretching groups each containing six students. The subjects in each group performed their respective stretching programs for 17 minutes, 3 times a week for 4 weeks. Lumbar lordotic angle, low back pain, and Oswestry Disability Index (ODI) were measured before and after the intervention. Results: Intragroup comparisons showed significant reductions in lumbar lordotic angle and low back pain in the static stretching group while the dynamic stretching group showed significant decreases in lumbar lordotic angle, low back pain, and ODI. The intergroup comparisons showed significantly greater differences between pre- and post-intervention in lumbar lordotic angle and low back pain in the dynamic stretching group compared to those in the static stretching group while ODI did not show any intergroup difference. Conclusions: The results of this study indicated that, while both static and dynamic stretching helped to reduce the lumbar lordotic angle and low back pain, dynamic stretching was more effective in alleviating lumbar lordotic angle and low back pain compared to static stretching.

A Noisy Videos Background Subtraction Algorithm Based on Dictionary Learning

  • Xiao, Huaxin;Liu, Yu;Tan, Shuren;Duan, Jiang;Zhang, Maojun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.1946-1963
    • /
    • 2014
  • Most background subtraction methods focus on dynamic and complex scenes without considering robustness against noise. This paper proposes a background subtraction algorithm based on dictionary learning and sparse coding for handling low light conditions. The proposed method formulates background modeling as the linear and sparse combination of atoms in the dictionary. The background subtraction is considered as the difference between sparse representations of the current frame and the background model. Assuming that the projection of the noise over the dictionary is irregular and random guarantees the adaptability of the approach in large noisy scenes. Experimental results divided in simulated large noise and realistic low light conditions show the promising robustness of the proposed approach compared with other competing methods.

Motion-Based Background Image Extraction for Traffic Environment Analysis (교통 환경 분석을 위한 움직임 기반 배경영상 추출)

  • Oh, Jeong-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1919-1925
    • /
    • 2013
  • This paper proposes a background image extraction algorithm for traffic environment analysis in a school zone. The proposed algorithm solves the problems by level changes and stationary objects to be occurred frequently in traffic environment. For the former, it renews rapidly the background image toward the current frame using a fast Sima-Delta algorithm and for the latter, it excludes the stationary objects from the background image by detecting dynamic regions using a just previous frame and a background image averaged for a long time. The results of experiments show that the proposed algorithm adapts quickly itself to level change well, and reduces about 40~80% of SAD in background region in comparison with the conventional algorithms.

An Illumination and Background-Robust Hand Image Segmentation Method Based on the Dynamic Threshold Values (조명과 배경에 강인한 동적 임계값 기반 손 영상 분할 기법)

  • Na, Min-Young;Kim, Hyun-Jung;Kim, Tae-Young
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.5
    • /
    • pp.607-613
    • /
    • 2011
  • In this paper, we propose a hand image segmentation method using the dynamic threshold values on input images with various lighting and background attributes. First, a moving hand silhouette is extracted using the camera input difference images, Next, based on the R,G,B histogram analysis of the extracted hand silhouette area, the threshold interval for each R, G, and B is calculated on run-time. Finally, the hand area is segmented using the thresholding and then a morphology operation, a connected component analysis and a flood-fill operation are performed for the noise removal. Experimental results on various input images showed that our hand segmentation method provides high level of accuracy and relatively fast stable results without the need of the fixed threshold values. Proposed methods can be used in the user interface of mixed reality applications.

Ultrafast Dynamic Contrast-Enhanced Breast MRI: Lesion Conspicuity and Size Assessment according to Background Parenchymal Enhancement

  • Soo-Yeon Kim;Nariya Cho;Yunhee Choi;Sung Ui Shin;Eun Sil Kim;Su Hyun Lee;Jung Min Chang;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.561-571
    • /
    • 2020
  • Objective: To evaluate the clinical utility of ultrafast dynamic contrast-enhanced (DCE)-MRI compared to conventional DCE-MRI by studying lesion conspicuity and size according to the level of background parenchymal enhancement (BPE). Materials and Methods: This study included 360 women (median age, 54 years; range, 26-82 years) with 361 who had undergone breast MRI, including both ultrafast and conventional DCE-MRI before surgery, between January and December 2017. Conspicuity was evaluated using a five-point score. Size was measured as the single maximal diameter. The Wilcoxon signed-rank test was used to compare median conspicuity score. To identify factors associated with conspicuity, multivariable logistic regression was performed. Absolute agreement between size at MRI and histopathologic examination was assessed using the intraclass correlation coefficient (ICC). Results: The median conspicuity scores were 5 at both scans, but the interquartile ranges were significantly different (5-5 at ultrafast vs. 4-5 at conventional, p < 0.001). Premenopausal status (odds ratio [OR] = 2.2, p = 0.048), non-mass enhancement (OR = 4.1, p = 0.001), moderate to marked BPE (OR = 7.5, p < 0.001), and shorter time to enhancement (OR = 0.9, p = 0.043) were independently associated with better conspicuity at ultrafast scans. Tumor size agreement between MRI and histopathologic examination was similar for both scans (ICC = 0.66 for ultrafast vs. 0.63 for conventional). Conclusion: Ultrafast DCE-MRI could improve lesion conspicuity compared to conventional DCE-MRI, especially in women with premenopausal status, non-mass enhancement, moderate to marked BPE or short time to enhancement.

Dynamic Scene Segmentation Algorithm Using a Cross Mask and Edge Information (Cross Mask와 에지 정보를 사용한 동영상 분할)

  • 강정숙;박래홍;이상욱
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.8
    • /
    • pp.1247-1256
    • /
    • 1989
  • In this paper, we propose the dynamic scene segmentation algorithm using a cross mask and edge information. This method, a combination of the conventioanl feature-based and pixel-based approaches, uses edges as features and determines moving pixels, with a cross mask centered on each edge pixel, by computing similarity measure between two consecutive image frames. With simple calcualtion the proposed method works well for image consisting of complex background or several moving objects. Also this method works satisfactorily in case of rotaitional motion.

  • PDF

Feature-Based Panoramic Background Generation for Object Tracking in Dynamic Video (가변시점 비디오 객체추적을 위한 특징점 기반 파노라마 배경 생성)

  • Im, Jae-Hyun;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.108-116
    • /
    • 2008
  • In this paper, we propose the algorithm for making panoramic background and object tacking using pan-tilt-zoom camera. We draw an analogy relation between images for cylinder projection, rearrange of images, stitching, and blending. We can then make the panoramic background, and can track the object use the panoramic background. After generated the background, the proposed algorithm tracks the moving object. Therefore it can detect the wide area, and it tracks the object continuously. So the proposed algorithm is able to use at wide area to detect and track the object.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF