• 제목/요약/키워드: Duty-ratio

검색결과 621건 처리시간 0.028초

승압인덕턴스 분산형 PWM 정류기 (Boosting Inductor Distribution Type PWM Rectifier)

  • 이무영;김우현;마진석;임성운;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1940-1943
    • /
    • 1998
  • A new PWM rectifier which offers a unity power factor is proposed. The circuit has same inductance as the conventional boosting type PWM rectifier in powering mode, but the inductance is splitted to 2 part in freewheeling mode. So the period of freewheeling mode is shorter than that of conventional boosting type PWM rectifier, and discontinuous input current is obtained in wide duty range. Therefore the proposed PWM rectifier accomplishs a unity power factor in wide range of duty ratio and boosting factor. And the conventional boosting type PWM rectifier has poor power factor near the unity boosting ratio, the proposed PWM rectifier improves this problem. The mathmatical analysis are presented and experimental results are given.

  • PDF

대기모드 기능을 내장한 전원 장치 제어용 PWM IC 설계 (Design of PWM IC with Standby Mode Control Function for SMPS)

  • 박현일;김형우;김기현;서길수;한석붕
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.289-295
    • /
    • 2008
  • In this paper, we designed the off-line PWM(Pulse width modulation) control IC for flyback type power converter to reduce the standby power consumption. In normal state, this off-line PWM IC generates the output pulse with $40\sim60kHz$ frequency and duty ratio of $20\sim88%$. When SMPS operates in standby mode, this IC generates the output pulse with 33kHz frequency and duty ratio of 1 %. SPICE simulation was performed to verify the standby power consumption of the power converter with designed of-line PWM IC. Power converter with designed off-line PWM IC consumes less than 0.3W when it operates in standby mode condition.

DDPWM Based Control of Matrix Converters

  • Li, Yu-Long;Choi, Nam-Sup;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.535-543
    • /
    • 2009
  • In this paper, pulse-width modulation (PWM) control strategy of various topologies of matrix converters is presented, which is based on direct duty ratio PWM (DDPWM). Because the DDPWM method has the characteristics of the inherent per-phase modular structure, it can be effectively applied to single-phase, two-phase and three-phase four-leg matrix converters as well as the common three-phase to three-phase matrix converter. Also, this paper treats command generation method in each matrix converter. The feasibility and validity of the proposed method are verified by experimental results.

Characteristics of Sŏlc Filters in X(2) Nonlinear Photonic Crystal

  • Kee, Chul-Sik;Lee, Jong-Min;Lee, Yeung-Lak
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.130-132
    • /
    • 2007
  • The characteristics of $S\breve{o}lc$ filters in $X^{(2)}$ nonlinear photonic crystals, periodically poled lithium niobate ($LiNbO_3$), were investigated by the Jones matrix method. The transmittance increases and the full width half maximum of the filter becomes narrow as the duty ratio increases. However, the filtering wavelength does not change. The transmittance at the filtering wavelength is over 95% when the duty ratio is larger than 0.35.

이중 쵸퍼 DC-DC 컨버터의 해석과 제어 (An analysis and control of double chopper DC-DC converter)

  • 한상완;신동희;홍석교
    • 제어로봇시스템학회논문지
    • /
    • 제3권6호
    • /
    • pp.576-581
    • /
    • 1997
  • DC-DC converter with chopper is seen to have problems, such as, loop instability and degradation of transient response, due to the interaction between input filter and switching regulator. In this paper, the switching regulator consisting of input filter and double chopper is analyzed, and the state space model at continuous current mode and the transfer function between duty ratio of switching pulse and output voltage are derived. The controller in this paper is designed as feedforward(P) and feedback(PI) control scheme to minimize the variation of output voltage, and computer simulation results are presented to show the performance of the proposed controller.

  • PDF

Boost 컨버터와 계통연계 인버터를 이용한 풍력발전의 센서리스 MPPT 제어 (Sensorless MPPT Control using a Boost Converter and a Grid Side Inverter in Wind Power Generation Systems)

  • 김도윤;이준민;김영석
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1372-1377
    • /
    • 2011
  • This paper proposes the control method of MPPT(maximum power point tracking) for the wind energy generation system using the duty ratio control of boost type DC-DC converter. For a lower cost and a higher reliability, the wind and the generator velocity sensors are removed. MPPT control is implemented by changing the duty ratio of the boost converter. Chain rule is applied by using each function. The grid side inverter is controlled to regulate unity power factor. The proposed control method was analyzed mathematically and verified by the computer simulation using PSIM.

A Simple Grid-Voltage-Sensorless Control Scheme for PFC Boost Converters

  • Nguyen, Cong-Long;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.712-721
    • /
    • 2014
  • This paper introduces a simple grid-voltage-sensorless control scheme for single-phase power factor correction (PFC) boost converters. The grid voltage waveform is obtained based on the dc output voltage, the switching duty ratio, and a phase-lead compensator. In addition, the duty ratio feedback is utilized to obtain the unity input power factor and the zero harmonic current. The proposed control scheme is designed and mathematically analyzed based on a small-signal model of PFC boost converters. To verify the effectiveness of the proposed control scheme, several simulations and experiments are carried out in two applications: an industrial power system with a 60 Hz grid frequency and a commercial aircraft application with a 400 Hz grid frequency.

적분기를 이용한 Cuk 컨버터의 순시추종형 PWM 제어 (Instantaneous Following PWM Control Strategy of Cuk Converter Using Integrator)

  • 손제봉;정순용;김광태;이우석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.103-105
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of Cuk converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with Cuk converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

브러시리스 직류전동기용 센서리스 드라이브의 토크 맥동 저감 방법 (Torque Ripple Reduction Method in a Sensorless Drive for BLDC Motor)

  • 이광운;김대경;김태덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1087-1089
    • /
    • 2003
  • This paper presents a method to reduce commutation torque ripple in a sensorless brushless DC motor drive without current sensors. To compensate the commutation torque ripple completely, the duration of commutation must be known. The proposed method measures the duration of commutation from terminal voltage waveforms, calculates a PWM duty ratio to suppress the commutation torque ripple from the output of speed controller, and applies the calculated PWM duty ratio only during the commutation. Experimental results show that vibrations are considerably reduced when the proposed method is applied to the sensorless brushless DC moter drive for air-conditioner compressor.

  • PDF

PDP용 MgO 박막의 스퍼터 연구 (Sputtering of Magnesium Oxide this film for Plasma Display Panel Application)

  • 최영욱;김지현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1732-1734
    • /
    • 2003
  • An MgO thin film sputtering system for the PDP (Plasma Display Panel) applications has been developed. This system was manufactured with a vertical In-Line type of 42 inch, which has the length of 520 mm and the width of 900 mm. A reactive magnetron discharge for this sputtering was generated using an unipolar pulsed power supply which has functions of constant voltage (Max. 500 V) and current (Max. 15 A) control, frequency of $10{\sim}100$ kHz and duty ratio of $10{\sim}60$ %. The experiment was conducted under various conditions : $3{\sim}10$ mTorr of pressure, the ratio of $O_2$/Ar = $0.1{\sim}0.5$, 50 % of duty and power of $0.5{\sim}1.7$ kW. From the experiment, the deposition rate of a static state and a moving state were measured to be about 45 nm/min and 6 nm m/min at the distance of 50 mm between the target and the substrate, respectively.

  • PDF