• Title/Summary/Keyword: Dust collecting

Search Result 73, Processing Time 0.023 seconds

Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator (설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측)

  • Suh, Jeong-Min;Yi, Pyong-In;Jung, Moon-Sub;Park, Jeong-Ho;Lim, Woo-Taik;Park, Chool-Jae;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

A Study on PM10 Control in Subway Tunnels Using Natural Polysaccharide Dust Collecting Agent (천연 다당류 먼지포집제를 이용한 지하철 터널 내 PM10 제어에 대한 연구)

  • Lee, Han-Seob;Hwang, Su-Jin;Hwang, Hyun-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.122-129
    • /
    • 2017
  • Objectives: Most of the $PM_{10}$ in subway stations is spread by the train-induced wind from the tunnels. Therefore, in order to improve air quality in subway stations, it is important to remove the $PM_{10}$ from the tunnels. After the installation of PSD (platform screen doors), the influence of train-induced wind and $PM_{10}$ at the platform has decreased, but is estimated to have increased in subway tunnels. This study was conducted to investigate the control of $PM_{10}$ in subway tunnels by applying a 500-fold diluted solution mixed with a humectant using a natural polymer. Methods: For this purpose, we tested the dust reduction effect in a laboratory and corrosion test and water pollution using fish and aquatic plants for the natural dust collecting agent. In the tunnel of a subway station, we used the natural dust collecting agent over 15 days. The study was carried out on $PM_{10}$ control during operation, which accounts for more than 70% of subway dust. Results: As results, the natural dust collecting agent exhibited an excellent dust control effect, and it was safe for water quality and soil. It showed the effect of controlling $PM_{10}$ in the subway tunnel by 49.5- 64.7% over 15 days. The use of the dust collecting agent for the control of $PM_{10}$ could be confirmed in the subway. Conclusion: It is necessary to clearly explain the major portions of chemical components contained in $PM_{10}$ to figure out the characteristics of $PM_{10}$ and to develop effective reduction measures to decrease the adverse effects of $PM_{10}$ in the subway.

Convergent Study on the Hydro-Gas Reforming Cyclo-Incinerator (물 가스 개질 고속선회 소각로에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.231-236
    • /
    • 2020
  • A water reforming reaction high-speed turning incinerator test facility was prepared. The reforming reaction chamber and the combustion chamber were directly connected. The incinerator and dust collecting device were integrated and made into a double bulkhead type air cooling structure. The blower is built into the dust collector to improve spatial efficiency. An axial flow type multi-stage dust collector was applied by collecting dust by using a plurality of dust collecting bins attached to the side of the dust collecting part. As a result of measuring dioxin among the exhausted gases, results below the standard value were obtained. As a result of measuring exhaust gas and heavy metals, results were obtained below the environmental standard.

An advanced study of multi-stage type hydrocyclone dust collector for fish egg collecting using Visualization (가시화기법을 이용한 다단형 하이드로 사이클론 어란 (魚卵) 집진장치의 개선에 관한 연구)

  • CHOI, Eunhee;PYEON, Yongbeom;LEE, Seung-heon;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.404-412
    • /
    • 2017
  • A centrifugal cyclone dust collecting apparatus includes a hydro cyclone dust collecting apparatus for separating solid or liquid using liquid or suspension as a medium. In this study, the formation mechanism and improvement of air core and inner air layer were confirmed through Particle Image Velocimetry. These results showed that the modified experimental model was designed in the conventional method suitable for the separation of juvenile fish and eggs. The inlet speed of the multi-stage hydrocyclone dust collector, which can increase the inlet velocity and minimize floatage in the turbulence chamber, was increased from 0.15 to 0.30 m/s. As a result, the air core was stably formed, the inner air layer was increased with increasing speed. In addition, the dust collecting efficiency of egg and juvenile fish was 97.8% on average, It can infer that this system confirmed the ability to efficiently collect particles of $40{\mu}m$ or more.

Variation of Collection Efficiency with Turbulence Model in a Mini Cyclone for Collecting Automobile Brake Fine Dust (자동차 브레이크 미세먼지 포집을 위한 미니 사이클론의 난류모델에 따른 포집효율 변화)

  • Han, Dong-Yeon;Lee, Young-Lim
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.47-52
    • /
    • 2021
  • Fine dust generated from vehicle brakes accounts for a significant amount of fine dust from non-exhaust system. Since such brake fine dust contains a large number of heavy metal components that are fatal to the human body, a device capable of collecting them needs to be developed. A mini cyclone, one of the devices that can effectively collect fine dust, has the advantage of relatively simple shape and high collection efficiency. Therefore, in this study, the collection efficiency of the mini-cyclone was numerically analyzed using CFD in order to find out whether such a mini-cyclone is suitable for collecting brake fine dust. As a result, the cut-off diameter was predicted to be about 1.5㎛, which means that the particle trapping load of the filter can be drastically reduced. Therefore, there is a possibility that the mini-cyclone can be used to collect fine dust from disc brakes.

Simultaneous Removal of Gas and Dust by Activated Carbon Coated Electrode

  • Kim, Kwang Soo;Park, Jung O;Lee, Ju Haeng;Jun, Tae Hwan;Kim, Ilho
    • Environmental Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.229-234
    • /
    • 2013
  • This study aimed to develop a new dust collecting system equipped with an activated carbon (A.C.) coated electrode. Before fabrication, pre-treatment of A.C. was performed to remove metal ions within the A.C. to enlarge its specific surface area. Then, pre-treated A.C., black carbon, polyvinyl acetate (PVAc), and methanol were mixed to make a gel compound, which was coated onto aluminum plates to fabricate electrodes. The optimal mixing ratio of A.C., black carbon, PVAc, and methanol was found to be 10 g: 2 g: 3 g: 20 mL. After fabrication, the electrodes were used in the batch-type experiment for $NH_3$ and $H_2S$ removal. The reduction rates of the gases were high at the beginning and slowly reduced with time. Dust collection experiments were conducted in continuous flow, with various voltages applied. Compared to 5 kV, dust removal efficiency was 1.5 times higher when 10 kV was applied. Increasing the number of electrodes applied also increased the collecting efficiency. The correlation coefficient between actual collecting efficiency and trend line was higher than 99%. Consequently, the novel dust collection system equipped with A.C. coated electrode appears to be a promising substitute for existing dust-control devices.

Development of Intelligent Solenoid Valve Controller for Dust Collecting System (집진장치용 지능형 솔레노이드 밸브 제어기의 개발)

  • Kang, Moon-Sung;Hong, Sung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • In this study, an intelligent solenoid valve controller has been developed for efficient maintaining of filters in a dust collecting system. This controller has automatic controllability of solenoid valves' ON/OFF time depending on the clogging status of filters, and then it can extend the filters' lifetimes, decrease the power consumption, and make effective operation of the system possible. This controllability has been executed by the fuzzy theory that utilizes the workers' experimental knowledges, the control expert's knowledges and the differential pressures between the inlets and outlets measured by the sensors. The system's operation is under the continuous surveillance by using a current transformer, which warns the operators and lets them take necessary actions in case of abnormal operation.

A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling (청정에너지 회수용 유증기/매연 포집모듈에 관한 연구)

  • Kim, Myung-Soo;Ohkura, Shigenobu;Ham, Koung-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

Development of Fine Dust Monitoring System Using Small Edge Computing (소형 엣지컴퓨팅을 이용한 미세먼지 모니터링 시스템 개발)

  • Hwang, KiHwan
    • Journal of Platform Technology
    • /
    • v.8 no.4
    • /
    • pp.59-69
    • /
    • 2020
  • Recently, the seriousness of ultrafine dust and fine dust has emerged as a national disaster, but small and medium-sized cities in provincial areas lack fine dust monitoring stations compared to their area, making it difficult to manage fine dust. Although the computing resources for collecting and processing fine dust data are not large, it is necessary to utilize cloud and private and public data to share data. In this paper, we proposed a small edge computing system that can measure fine dust, ultrafine dust and temperature and humidity and process it to provide real-time control of fine dust and service to the public. Collecting fine dust data and using public and private data to service fine dust ratings is efficient to handle with edge computing using raspberry pie because the amount of data is not large and the processing load is not large. For the experiment, the experiment system was constructed using three sensors, raspberry pie and Thinkspeak, and the fine dust measurement was conducted in northern part of kyongbuk region. The results of the experiment confirmed the measured fine dust measurement results over time based on the GIS data of the private sector.

  • PDF

Investigation of the Concentration of PM2.1 & PM10 and Alveolar Deposition Ratio (미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사)

  • Kim, Seong Cheon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • Objectives: In this study, a nine-stage cascade impactor was used to collect dust, and the concentration of $PM_{2.1}$ & $PM_{10}$ and alveolar deposition ratio were investigated. Methods: This study was conducted at Kunsan National University from May to June 2016. A nine-stage Cascade Impactor was used to analyze the concentrations of fine and ultrafine dust and to estimate the alveolar deposition rate by particle size of atmospheric dust particles. The pore size of each stage of the collector used in this study gradually increased from F to 0, with the F-stage as the last stage. Results: The mass fraction of PM showed a bimodal distribution divided into $PM_{2.1}$ & $PM_{10}$ based on $2.1-3.1{\mu}m$. The average mass fraction of particulate matter in the range of $2.1-3.1{\mu}m$ was 44%, and the area occupied by $PM_{2.1}$ was similar. Therefore, the Gunsan area is considered to be a region where there are similar effects from anthropogenic and natural sources. Conclusion: Dust collecting efficiency increased with the stage of collecting fine dust, and the efficiency of collection was very low at the stage of collecting ultra-fine dust. The seasonal overall efficiency of the Cascade Impactor was 44% in spring and 37.4% in summer, and the average overall efficiency was 40.7%. The alveolar deposition rate of $PM_{2.1}/PM_{10}$ during the sampling period was estimated to be about 75% deposited in the alveoli.