• Title/Summary/Keyword: Dust Prevention

Search Result 117, Processing Time 0.028 seconds

Anti-inflammatory Effects of Hataedock with Douchi in Atopic Dermatitis-like Skin Lesions in House Dust Mite-Induced NC/Nga Mice (PKC 활성 조절을 통한 두시 하태독법의 항염증작용이 Mite 항원 유도 아토피유사피부염 발병 조절에 미치는 효과)

  • Ahn, Sang Hyun;Kim, Ki Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.77-86
    • /
    • 2016
  • Objectives Hataedock (HTD) is an oral Korean herbal medical oral treatment that removes fetal toxic heat and meconium from new born babies. The purpose of this study is to evaluate whether Hataedock treatment of Duchi extracts has anti-inflammation effects in atopic dermatitis-like skin lesions in House Dust Mite-Induced NC/Nga Mice. Methods The mice were divided into 3 groups (n=10 per group) as follows: the control group (Ctrl group), AD-induced group (AE group), AD-induced with HTD treatment group (DT group). 3-week-old NC/Nga mice were introduced to Hataedock treatment, made of Duchi extract. After 4 weeks, House Dust Mite-Induced application was used six times per week for 3 weeks to induce the first atopic dermatitis, and second AD in 7 weeks after. To examine skin injuries and anti-inflammatory effect, PKC, MMP-9, iNOS immunohistochemistry were used. Results The alleviate effect of the skin damage and angiogenesis was observed in DT group. The damage of stratum corneum, hyperplasia, edema, infiltration of lymphocytes and distribution of capillary were decreased in DT group. Also, the study results suggested that Hataedock treatment made of Duchi extracts in DT group remarkably decreased skin damages by 51% (p < 0.001), as well as PKC by 91%, MMP-9 by 48% (p < 0.001), iNOS by 51% (p < 0.001). Conclusions Based on the study results, we observed that Hataedock treatment of Duchi extracts alleviates AD by diminishing various inflammatory cytokines, initial steps of AD development, in the skin lesions. Potential applications for prevention and treatment of atopic dermatitis are expected.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 1. Analysis of Pollution Incidents occurred in Shipyards (국내 조선소 주변해역의 해양오염 현황 - 1. 조선소 오염사고 분석)

  • Kim, Kwang-Soo;Han, Won-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.646-652
    • /
    • 2014
  • Data of pollution incidents which occurred in shipyards of South Korea for 10 years from 2004 to 2013 were collected and analyzed in order to propose the plans for the prevention of pollution incidents in shipyards. Total number of pollution incidents in shipyards was 103 cases over the nation of Korea for the recent 10 years and the average annual number was about 10 cases, and annual cases tended to increase from 8 cases in 2004 to 23 cases in 2010 and then to decrease to 9 cases in 2013. The location data of pollution incidents showed 32 cases in Busan metropolitan city (31%), 30 cases in Jeonnam (29%), 21 cases in Gyeongam (21%), 5 cases in Jeju (5%), 4 cases in Gangwon (4%), 4 cases in Gyeongbuk (4%), 3 cases in Chungnam (3%) and 3 cases in Incheon metropolitan city (3%). According to the data of work types of shipyards, 60 cases happened during the work of ship repair (58%), 25 cases during the work of ship breakup (24%), 10 cases in the course of ship building (10%) and 8 cases by others (8%). The data of pollutant type showed oil and oily mixtures to be 59 cases (57%), waste paint dust to be 22 cases (21%), iron dust and welding slag to be 13 cases (13%), wastes to be 4 cases (4%), waste FRP powder to be 3 cases (3%), and others to be 2 cases (2%). The plans for the prevention of pollution incidents in shipyards of Korea were proposed as follows; (1) Observance of the related laws and regulations, (2) Establishment and implementation of action plans to prevent areas dense with shipyards from causing pollution incidents, (3) Establishment and implementation of oil pollution prevention plans in shipyards, especially during the ship repair and breakup works, (4) Preparation of measures to solve civil complaints against pollution incidents in shipyards, and (5) Improvement in national management for the control of shipyards.

A Systematized Overview of Published Reviews on Biological Hazards, Occupational Health, and Safety

  • Alexis Descatha;Halim Hamzaoui;Jukka Takala;Anne Oppliger
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.347-357
    • /
    • 2023
  • Introduction: The COVID-19 pandemic turned biological hazards in the working environment into a global concern. This systematized review of published reviews aimed to provide a comprehensive overview of the specific jobs and categories of workers exposed to biological hazards with the related prevention. Methods: We extracted reviews published in English and French in PubMed, Embase, and Web of Science. Two authors, working independently, subsequently screened the potentially relevant titles and abstracts recovered (step 1) and then examined relevant full texts (step 2). Disagreements were resolved by consensus. We built tables summarizing populations of exposed workers, types of hazards, types of outcomes (types of health issues, means of prevention), and routes of transmission. Results: Of 1426 studies initially identified, 79 studies by authors from every continent were selected, mostly published after 2010 (n = 63, 79.7%). About half of the reviews dealt with infectious hazards alone (n = 38, 48.1%). The industrial sectors identified involved healthcare alone (n = 16), laboratories (n = 10), agriculture (including the animal, vegetable, and grain sectors, n = 32), waste (n = 10), in addition of 11 studies without specific sectors. The results also highlighted a range of hazards (infectious and noninfectious agents, endotoxins, bioaerosols, organic dust, and emerging agents). Conclusion: This systematized overview allowed to list the populations of workers exposed to biological hazards and underlined how prevention measures in the healthcare and laboratory sectors were usually well defined and controlled, although this was not the case in the agriculture and waste sectors. Further studies are necessary to quantify these risks and implement prevention measures that can be applied in every country.

The Particle Size Characteristics of Coal Preparation Plant in a Coal Mine (석탄광산 선탄장에서의 발생 분진의 입도분포 특성)

  • Ok, Yun-Yong;Hur, Jun-Seok;Lee, Seung-Chul;Kim, So-Young;Chio, Kwang-Su
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.263-266
    • /
    • 2009
  • 석탄광산의 선탄장(選炭場)에서 운용하는 장치들로부터 발생하는 석탄분진의 입도분포를 현장조사와 실내분석을 통하여 파악하였으며, 연구결과는 광해(鑛害)로서 작용하는 석탄분진을 포집하는 집진기(A Dust Collector)의 설계에 필요한 자료로 제시하고자 한다. 연구결과 TB업체의 분진 입도분포는 $1{\mu}m$이하의 미세(微細)입자와 $100{\mu}m$이상의 조대(粗大)입자가 차지하는 비중이 미약한 반면, 특히 $5{\mu}m{\sim}80{\mu}m$ 사이에 분포되는 분진들이 89.2%로 나타나 발생분진의 대부분을 차지하는 것으로 파악되었다. 이들 중 원심집진기에 포집된 분진은 $70{\mu}m$이하에서 89.5%인 반면 여과집진기에서 포집된 분진의 90.0%가 $20{\mu}m$이하인 것으로 나타났다. SD업체의 분진 또한 $1{\mu}m$이하와 $100{\mu}m$이상 입자는 적은 분포를 보인 반면, $5{\mu}m{\sim}70{\mu}m$사이에 분포되는 분진들이 89.6%로 나타나 발생분진의 대부분을 차지하는 것으로 파악되었다. 이들 중 여과집진기에 포집된 분진의 입도는 $30{\mu}m$이하에서 96.2%인 것으로 나타났다.

  • PDF

The Study on the Optimal Operating Conditions of Direct Charging Type Electrospray for Particulate Matter Collection (미세먼지 집진을 위한 직접 하전 방식 정전분무의 최적 동작 조건에 관한 연구)

  • Sugi Choi;Sunghwan Kim;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.474-481
    • /
    • 2023
  • This paper is an experimental study on the optimal operating conditions of direct charging type electrospray for particulate matter collection. To perform the research, a direct charging type electrospray visualization system was configured to photograph the spray shape of microdroplets, and experiments were performed with varying electrode distance, flow rate, and applied voltage, which are the main factors affecting the particulate matter collection efficacy. Through image processing, the total number of microdroplets according to each condition was analyzed, and the number of microdroplets with a diameter of 1.5 mm or less was confirmed. In addition, by calculating the number of microdroplets per power consumption according to the applied voltage, the optimal operating conditions were derived in terms of energy consumption efficacy, and the microdroplet size distribution was analyzed under the optimal operating conditions. As a result of the experiment, it was confirmed that the optimal operating condition was at a flow rate of 10 mL/min and a voltage of -20 kV in case of 5 mm electrode distance, and at a flow rate of 15 mL/min and a voltage of -30 kV in case of 100 mm electrode distance.

A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments (화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석)

  • Jeong-il Lee;Jong-Hwa Im
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station (지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가)

  • Park, Dae Hoon;Hwang, Jungho;Shin, Dongho;Kim, Younghun;Lee, Gunhee;Park, Inyong;Kim, Sang Bok;Hong, Keejung;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

Clinical Year-in-Review of Occupational Lung Disease (호흡기내과의사를 위한 직업성 폐질환 리뷰)

  • Lee, Won-Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.5
    • /
    • pp.317-321
    • /
    • 2011
  • Occupational lung disease (OLD) is a group of lung diseases caused and/or aggravated by organic and inorganic inhaled dust, fumes, and mist. OLD can develop under various occupational situations. Therefore, occupational history should be considered when evaluating respiratory symptoms. Once OLD is developed, it may not be treated and may even progress after exposure to the causative agents has stopped. The best ways to treat OLD are prevention and early detection by controlling the working environment and conducting regular surveillance of workers. Common OLDs in Korea are coal worker's pneumoconiosis, asbestos-related diseases, and occupational asthma. Recent aspects of these common OLDs in Korea will be described based on recently published studies.