• Title/Summary/Keyword: Duration reduction

Search Result 708, Processing Time 0.032 seconds

Performance Elements for Schedule Compression in Slab Form Work for High-rise Buildings (초고층 바닥거푸집 공사 공기단축을 위한 현장 요구 성능도출)

  • Lim, Hyun-Su;Kim, Tae-Hoon;Cho, Hun-Hee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.167-170
    • /
    • 2010
  • In tall building construction, It is important to reduce construction duration of slab form work. Therefore, the purpose of this study is to assess the required performance for reduction of construction duration in slab form work of tall buildings. We surveyed the required performance and their degrees of importance and economical efficiency through the interview and questionnaire survey by related experts. This study proposes the guideline to develop improved formwork system for reduction of construction duration.

  • PDF

Effect of Mating Duration and Multiple Use of Male Moth on Reproductive Performance of Some Cross Breeds of Silkworm, Bombyx mori L.

  • Sarkar, Kunal;Mandal, Manmatha;Moorthy, Shanmugam Manthira
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.19 no.2
    • /
    • pp.215-219
    • /
    • 2009
  • The effect of mating duration and multiple use of male on fecundity and fertility was investigated in the hybrids of Silkworm, Bombyx mori L. One hour to five hours of mating duration did not affect egg laying (fecundity) significantly, while fertilization affected significantly. Below 50% fertility was noticed when mating duration was reduced to below two hours. Similarly multiple use of male caused significant reduction in fertility but not fecundity. Till fourth mating no significant reduction in fertility was observed, thereafter fertility reduced considerably.

Phonetic Vowel Reduction Conditioned by Voicing of Adjacent Stops in English (음성적 모음 축소 현상에 영어 자음의 유무성 환경이 미치는 효과)

  • Oh, Eun-Jin
    • Speech Sciences
    • /
    • v.14 no.4
    • /
    • pp.81-98
    • /
    • 2007
  • This study aims to investigate whether shortened vowel duration conditioned by a following voiceless stop induces phonetic reduction of vowel space in English, and whether the reduction appears more in the height dimension than in the backness dimension (Lindblom, 1963; Flemming, 2005). Fifteen native speakers of American English read minimal pairs containing ten American English vowels in [bVd] and [bVt] syllables in a carrier phrase. All the subjects produced shorter vowels in the voiceless than in the voiced context. However, a reduction in vowel space and a raising of low vowels due to the shortened vowel duration were generally not found. To the contrary, the speakers tended to exhibit even more lowering of low vowels in the voiceless context, and vowel space was more commonly compressed in the backness dimension than in the height dimension. Many speakers, in particular, demonstrated fronting of the high back vowel [u] in the voiceless context. It was interpreted that due to a relatively large number of English vowels in the narrower low vowel space, the raising of low vowels may give rise to confusion in vowel contrasts, and therefore the degree of phonetic vowel reduction is restricted in that region. On the other hand, the high vowel region, being relatively spacious in English, allows a certain degree of phonetic vowel reduction in the F2 dimension. It is possible that heavy requirements for maintaining vowel contrasts may cause speakers to overachieve vowel target values, especially when faced with vowels which are difficult to distinguish due to shortened vowel duration, leading to an over-lowering of the low vowels.

  • PDF

A Competitive Advantage Analysis of Construction Duration through the Comparison of Actual Data of Domestic Construction Firms - Focused on Mix-Use Residential Building and Officetel Building - (건설사별 공기비교를 통한 공기경쟁력 분석 - 주상복합 및 오피스텔 건물을 중심으로 -)

  • Ryu, Han-Guk;Kim, Sun-Kuk;Lee, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.1 s.29
    • /
    • pp.138-147
    • /
    • 2006
  • Construction companies have been interested in the construction duration which importantly affects the performance and the success of the construction projects in accordance with the systemic changes such as five days per week system, introduction of construction duration reduction bidding system and post sale system nowadays. It is also very important to estimate and forecast properly the construction duration as the construction companies compete for the projects in the situation of construction market reduction and the lowest bidding system. Recognizing the importance about the construction duration, the researches about comparing and analyzing or estiamting the construction duration have been performed. However, comparing studies about the construction duraion have been limited to the apartment and office building in domestic area. Many studies about forecasting construction duration have been performed through stochastic analysis and simulations. Little research has been addressed the comparison analysis of the real construction duration about the mix-use building and officetel building which occured according to the changes of the building requirements. Therefore, the objective of this study is to compare and analyze the real construction duration and the hypothetical construction duration about the mix-use building and officetel building of the domestic companies. Moreover, we select the most competitve construction company to get the strengths and analyze the competitive advatages of the construction companies about construction duration.

Identifying Priority Area for Nonpoint Source Pollution Management and Setting up Load Reduction Goals using the Load Duration Curve (부하지속곡선을 이용한 비점오염원 우선관리 지역 선정 및 관리목표 설정 연구)

  • Jang, Sun Sook;Ji, Hyun Seo;Kim, Hak Kwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.17-27
    • /
    • 2018
  • The objective of this study is to identify the priority area where the nonpoint source pollution (NPS) management is required and to set up the load reduction goals for the identified priority area. In this study, the load duration curve (LDC) was first developed using the flow and water quality data observed at 286 monitoring stations. Based on the developed LDC, the priority area for the NPS pollution management was determined using a three-step method. The 24 watersheds were finally identified as the priority areas for the NPS pollution management. The water quality parameters of concern in the priority areas were the total phosphorus or chemical oxygen demand. The load reduction goals, which were calculated as the percent reduction from current loading levels needed to meet target water quality, ranged from 67.9% to 97.2% during high flows and from 40.3% to 69.5% during moist conditions, respectively. The results from this study will help to identify critical watersheds for NPS program planning purposes. In addition, the process used in this study can be effectively applied to identify the pollutant of concern as well as the load reduction target.

Air Pressure Enema Reduction in Infant and Childhood Intussusception (장중첩증 환아의 공기압 정복)

  • Jun, Si-Youl
    • Advances in pediatric surgery
    • /
    • v.3 no.2
    • /
    • pp.126-132
    • /
    • 1997
  • Reduction of intussusception using air or oxygen has wide acceptance as an alternative to conventional hydrostatic reduction. This study was undertaken to evaluate the results and complications of air pressure enema in 948 pediatric intussusception. One hundred and twenty nine cases were operated on at the Department of Surgery, Masan Samsung Hospital from 1985 to 1996 because of air reduction failure. The success rate was 86.4 %. Twenty-one patients(2.2 %) showed perforation during air reduction. Risk prone factors of perforation were; age less than 3 months(42.9 % vs 11.1 %), duration of symptoms greater than 48 hours (66.7 % vs 33.3 %), and presence of pathologic leading point(28.6 % vs 3.7 %). Vomitting and spontaneous rectal bleeding revealed higher prediction to the complication. In nineteen cases, bowel infarction, coagulated necrosis and hemorrhage suggested that the cause of perforation was due to the preexisting strangulation. In conclusion, when doing an air pressure enema reduction, care must be taken if the patient is of a young age or the symptoms are of long duration.

  • PDF

Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor (DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축)

  • 김경서
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

Effect of Sharbat Afsantīn in Poly Cystic Ovarian Disease - An Open Observational Study

  • Zubair, Zainab;Shameem, Ismath;Begum, Wajeeha
    • CELLMED
    • /
    • v.12 no.3
    • /
    • pp.10.1-10.12
    • /
    • 2022
  • Objective: The objective of the study was to evaluate the effect of Sharbat Afsantin in Polycystic Ovarian Disease. Methods: An open observational study was carried out in the Department of Ilmul Qabalat wa Amraze Niswan. Diagnosed cases(n=30) of PCOD were included in the study. Patients with thyroid dysfunction, systemic diseases, on hormonal treatment in last three months, pregnancy and lactation were excluded. Research drug (Sharbat Afsantin) was administered orally in a dose of 25ml twice daily for 15 days/cycle for three consecutive cycles. Outcome measures were, changes in subjective parameters (duration of cycle, duration and amount of flow and weight reduction) and objective parameters {pictorial blood loss assessment chart (PBAC) score, basal metabolic index (BMI), modified Ferriman Gallwey (mFG) score, acanthosis nigricans scale and pelvic ultrasonography}. Data were analyzed using paired Student 't' test. Results: Changes in duration of cycle, duration and amount of flow were achieved in 83.3%, 50% and 40% patients respectively and weight reduction in 30% patients. Changes in PBAC score and BMI were achieved in 50% and 30% patients respectively and 30% patients showed normal findings on pelvic ultrasonography. Conclusion: Sharbat Afsantin can be used as an alternate remedy in PCOD patients, as it has significant effect to regularize menstruation by reduction in BMI and probably by improving insulin resistance in PCOD. No adverse effect of Sharbat Afsantin was noted during the trial.

EFFECTS OF MILLING DURATION ON THE THERMOELECTRIC PROPERTIES OF N-TYPE Bi2Te2.7Se0.3

  • MIN-SOO PARK;HYE-YOUNG KOO;YONH-HO PARK;GOOK-HYUN HA
    • Archives of Metallurgy and Materials
    • /
    • v.64 no.2
    • /
    • pp.591-595
    • /
    • 2019
  • In this study, an oxide reduction process and a reduction-sintering process were employed to synthesize a thermoelectric alloy from three thermoelectric composite oxide powders, and the thermoelectric properties were investigated as a function of the milling duration. Fine grain sizes were analyzed by via X-ray diffraction and scanning electron microscopy, to investigate the influence of the milling duration on the synthesized samples. It was found that microstructural changes, the Seebeck coefficient, and the electrical resistivity of the compounds were highly dependent on the sample milling duration. Additionally, the carrier concentration considerably increased in the samples milled for 6 h; this was attributed to the formation of antisite defects introduced by the accumulated thermal energy. Moreover, the highest value of ZT (=1.05) was achieved at 373K by the 6-h milled samples. The temperature at which the ZT value maximized varied according to the milling duration, which implies that the milling duration of the three thermoelectric composite oxide powders should be carefully optimized for their effective application.

Analysis of Runoff Reduction Effect and Rainfall Intensity-Duration Time of Permeable Block Facility (투수블록시설의 유출저감효과 분석 및 강우강도-지속시간 관계 분석)

  • Han, Sangyun;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Non-point pollution adversely affects the water system and its influence is increasing. In order to manage such nonpoint source pollution, the government has conducted studies on LID (Low Impact Development) facilities and various efficiency evaluations. In this study, the actual installed permeable block facility among the various LID facilities was analyzed the effluent reduction rate, the residual rainfall analysis, the runoff duration time and the reduction rate of the maximum inflow and outflow for the rainfall runoff control and the results were compared the other facilities. The analysis results show that the reduction efficiency is high in order of impermeable block, filter type permeable block, and clearance type permeable block, and the graph showing the relationship between the rainfall intensity and the runoff duration time is presented. This graph can be helpful in the design of facilities such as the facility capacity selection according to the reproduction period of the permeable block facility similar to this.