• Title/Summary/Keyword: Duration of cyclic loading

Search Result 18, Processing Time 0.023 seconds

An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading (실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구)

  • 심재욱;박근보;최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.329-337
    • /
    • 2002
  • Based on the equivalent uniform stress concept presented by Seed and Idriss, sinusoidal cyclic loads which simplified the earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. In this study, the criterion of the liquefaction resistance strength was determined by applying real earthquake loading to the cyclic triaxial test. From the test results, relationships between liquefaction behaviors of saturated sand and earthquake characteristics such as magnitude or time-duration were determined. Magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were also proposed.

Application of frictional sliding fuse in infilled frames, fuse adjustment and influencing parameters

  • Mohammadi-Gh, M.;Akrami, V.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.6
    • /
    • pp.715-727
    • /
    • 2010
  • An experimental investigation is conducted here to study the effects of applying frictional sliding fuses (FSF) in concrete infilled steel frames. Firstly, the influences of some parameters on the behavior of the sliding fuse are studied: Methods of adjusting the FSF for a certain sliding strength are explained and influences of time duration, welding and corrosion are investigated as well. Based on the results, time duration does not significantly affect the FSF, however influences of welding and corrosion of the constitutive plates are substantial. Then, the results of testing two 1/3 scale single-storey single-bay concrete infilled steel frames having FSF are presented. The specimens were similar, except for different regulations of their fuses, tested by displacement controlled cyclic loading. The results demonstrate that applying FSF improves infill behaviors in both perpendicular directions. The infilled frames with FSF have more appropriate hysteresis cycles, higher ductility, much lower deteriorations in strength and stiffness in comparison with regular ones. Consequently, the infills, provided with FSF, can be regarded as an engineered element, however, special consideration should be taken into the affecting parameters of their fuses.

Experimental investigation of local damage in high strength concrete columns using a shaking table

  • Bairrao, Rogerio;Kacianauskas, Rimantas;Kliukas, Romualdas
    • Structural Engineering and Mechanics
    • /
    • v.19 no.5
    • /
    • pp.581-602
    • /
    • 2005
  • In this paper the accumulation of local damage during the cyclic loading in reinforced high-strength concrete columns is experimentally investigated. Two identical column specimens with annular cross-section and spiral reinforcement were designed and two tests, up to failure, under the action of a constant vertical concentrated force and a time-dependent concentrated horizontal force, were carried out at the LNEC shaking tables facility. Sine type signals, controlled in amplitude, frequency and time duration were used for these experiments. The concept of local damage based on local stiffness degradation is considered in detail and illustrated by experimental results. The specimens were designed and reinforced in such a way that the accumulation of damage was predicted by dominating deformations (cracking and crushing of the concrete) while the increasing of the loading values was a dominating factor of damage. It was observed that the local damage of HSC columns has exposed their anisotropic local behaviour. The damage accumulation was slightly different from the expected in accordance with the continuum damage concept, and a partial random character was observed.

Energy-Based Seismic Evaluation of Reinforced Concrete Structures I - Flexural Components (에너지에 근거한 철근콘크리트 구조물의 내진성능 평가 I - 휨요소)

  • 김장훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.33-44
    • /
    • 1999
  • An energy balance procedure is developed to incorporate the effects of earthquake duration which involves the effect of cyclic loading and the corresponding cumulative plastic deformation. Particular emphasis is given to the flexural failure of non-seismically designed columns of reinforced concrete frames. For this, conceptual strength deterioration models for columns, governed by concrete, anchorage failure and longitudinal steel fracture due to low-cycle fatigue, are proposed. It is evident that the energy-based method has good agreement with the experimental data and is able to predict the failure mode.

  • PDF

Electrode Fabrication of MWCNT-PDMS Strain Sensors by Wet-etching (습식 식각을 이용한 MWCNT-PMDS 변형율 센서 전극 생성에 관한 연구)

  • Jung, La-Hee;Hwang, Hui-Yun
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.387-393
    • /
    • 2021
  • This paper investigated the electrical properties of multiwall carbon nanotube reinforced polydimethylsiloxane (CNT-PDMS) strain sensors with copper electrodes on the wet-etched surface. MWCNT-PDMS strain sensors were fabricated according to the wt% of MWCNT. Surfaces on the electrode area were wet-etched with various etching duration and silver epoxy adhesives were spread on the wet-etched surface. Finally, we attached the copper electrodes to the MWCNT-PMDS strain sensors. We checked the electric conductivities by the two-probe method and sensing characteristics under the cyclic loading. We observed the electric conductivity of MWCNT-PDMS strain sensors increased sharply and the scattering of the measured data decreased when the surface of the electrode area was wet-etched. Initial resistances of MWCNT-PDMS strain sensors were inversely proportion to wt% of MWCNT and the etching duration. However, the resistance changing rates under 30% strain increased as wt% of MWCNT and the etching duration increased. Decreasing rate of the electric resistance change after 100 repetitions was smaller when wt% of MWCNT was larger and the etching duration was short. This was due to the low initial resistance of the MWCNT-PMDS strain sensors by the wet-etching.

4D full-field measurements over the entire loading history: Evaluation of different temporal interpolations

  • Ana Vrgoc;Viktor Kosin;Clement Jailin;Benjamin Smaniotto;Zvonimir Tomicevic;Francois Hild
    • Coupled systems mechanics
    • /
    • v.12 no.6
    • /
    • pp.503-517
    • /
    • 2023
  • Standard Digital Volume Correlation (DVC) approaches are based on pattern matching between two reconstructed volumes acquired at different stages. Such frameworks are limited by the number of scans (due to acquisition duration), and time-dependent phenomena can generally not be captured. Projection-based Digital Volume Correlation (P-DVC) measures displacement fields from series of 2D radiographs acquired at different angles and loadings, thus resulting in richer temporal sampling (compared to standard DVC). The sought displacement field is decomposed over a basis of separated variables, namely, temporal and spatial modes. This study utilizes an alternative route in which spatial modes are con-structed via scan-wise DVC, and thus only the temporal amplitudes are sought via P-DVC. This meth-od is applied to a glass fiber mat reinforced polymer specimen containing a machined notch, subjected to in-situ cyclic tension, and imaged via X-Ray Computed Tomography. Different temporal interpolations are exploited. It is shown that utilizing only one DVC displacement field (as spatial mode) was sufficient to properly capture the complex kinematics up to specimen failure.

Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket (천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능)

  • Lee, Seung-Jae;Kwak, Eui-Shin;Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

A New Detailed Assessment for Liquefaction Potential Based on the Liquefaction Driving Effect of the Real Earthquake Motion (실지진하중의 액상화 발생특성에 기초한 액상화 상세평가법)

  • 최재순;강한수;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.145-159
    • /
    • 2004
  • The conventional method for assessment of liquefaction potential proposed by Seed and Idriss has been widely used in most countries because of simplicity of tests. Even though various data such as stress, strain, stress path, and excess pore water pressure can be obtained from the dynamic test, especially, two simple experimental data such as the maximum deviatoric stress and the number of cycles at liquefaction have been used in the conventional assessment. In this study, a new detailed assessment for liquefaction potential to reflect both characteristics of real earthquake motion and dynamic soil resistance is proposed and verified. In the assessment, the safety factor of the liquefaction potential at a given depth of a site can be obtained by the ratio of a resistible cumulative plastic shear strain determined through the performance of the conventional cyclic test and a driving cumulative plastic shear strain calculated from the shear strain time history through the ground response analysis. The last point to cumulate the driving plastic shear strain to initiate soil liquefaction is important for this assessment. From the result of cyclic triaxial test using real earthquake motions, it was concluded that liquefaction under the impact-type earthquake loads would initiate as soon as a peak loading signal was reached. The driving cumulative plastic shear strain, therefore, can be determined by adding all plastic shear strains obtained from the ground response analysis up to the peak point. Through the verification of the proposed assessment, it can be concluded that the proposed assessment for liquefaction potential can be a progressive method to reflect both characteristics of the unique soil resistance and earthquake parameters such as peak earthquake signal, significant duration time, earthquake loading type, and magnitude.