• Title/Summary/Keyword: Durability testing

검색결과 303건 처리시간 0.033초

로드 프로파일 재현 소프트웨어 개발 (Development of Road Profile Realization Software)

  • 류신호;정상화;김우영;나윤철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.265-268
    • /
    • 1997
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structures of the automotwe vehicle. Component testing is part~cularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, multi-axial road simulator is used to carry out the fatigue test and the vibration test. In this paper, the algorithm and software to realize the real road profile are developed. The validity of the software are verified by applying the belgian road, the city road, the highway, and the gravel road. The results of the above experiment show that the real road profiles are realized well after loth iteration.

  • PDF

접촉압력을 고려한 R-134a용 냉도기유의 윤활성 평가 연구

  • 나병철;전경진;한동철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.145-151
    • /
    • 1997
  • PAG(Polyalkylene Glycol) and esters are tested with HFC-134a as a refrigeration oil. This investigation enhances the testing method by taking the compressor's environment into account. A testing environment charged with refrigerant gas more closely simulates the conditions of a compressor. The friction coetTicient of the PAG/HFC-134a system is similar to that of the mineral oil/CFC-12 system at operating conditions. Ester oils are preferable at the start & stop condition in the lubricity aspect. PAG shows good lubricity in conditions of extreme contact pressure. Consequently, this test provides reliable results on compressor lubricity of refrigeration oils with HFC-134a. It suggests a methodological way for the proper selection of refrigeration oils that may improve the durability and performance of a compressor.

  • PDF

지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법 (Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint)

  • 오규환;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF

배전선로용 가스절연부하개폐기의 신뢰성 향상책 (Reliability for SF6 gas load break switch of distribution system)

  • 박승재;허종철;신영준;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF

배전 실증시험장 시스템 현황 소개 (Introduction of the field - test evaluation system in KEPCO)

  • 김동명;최선규;장상옥;오재형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

해양구조물 전기방식시스템 현장적용실험장 설계 (Field Testing Center Design of Cathodic Protection System for Maritime Metallic Structures)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.633-636
    • /
    • 2003
  • Most of maritime metallic structures are adopted a CP(Cathodic Protection) System for protection of corrosion in advanced country. So, we had been developed a remote corrosion monitoring control system. And we want to know the characteristics of efficiency, reliability, durability and so on. On the view point of it, we have to test in real field. in terms of design, cathodic protection systems, corrosion monitoring systems and optimal corrosion control systems compare to general commercial products. So, these systems have being studied to improve their capability. In this paper, the result of field testing center design of intelligent cathodic protection system including anodes, a real-time wireless remote corrosion monitoring and corrosion control system are described in naval ports.

  • PDF

Long-term Mechanical Behavior of CFRP-strengthened Steel Members for a Truss Tower

  • Nakamoto, Daiki;Yoresta, Fengky Satria;Matsui, Takayoshi;Mieda, Genki;Matsuno, Kazunari;Matsumoto, Yukihiro
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.343-349
    • /
    • 2020
  • This research aimed to clarify the long-term mechanical performance of a steel truss member strengthened by a carbon fiber-reinforced polymer (CFRP) without protective coating through exposure testing. Strengthening and repair methods using CFRP have been developed in recent years; however, there is a lack of durability research for CFRP-strengthened members, especially mechanical performance investigation according to actual exposure testing. In this study, 10 CFRP-strengthening steel specimens were created in 2015, and elastic bending tests were conducted biannually. Eventually, although resin loss occurred due to environmental effects, the mechanical performance of CFRP-strengthened steel was not degraded, and we propose a calculation method of bending stiffness to evaluate the lower value of stiffness for design.

차염성 저발열시멘트의 급속동결융해 저항성에 관한 실험적 연구 (An Experimental Study on Resistance of rapid Freezing and Thawing of Chloride-inhibiting Low-Heat Cement)

  • 심종성;박철우;박성재;강태성;주민관;김태수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.589-592
    • /
    • 2008
  • 이 연구는 겨울철 동결융해 작용으로 인한 차염성 저발열시멘트(CLC)의 내구성을 알아보고자 수행하였다. 내구성 문제는 현장여건에 따라 다소 차이는 있으나, 계절변화에 따른 반복적인 동결융해작용에 의한 콘크리트의 동해는 내구성 저하의 대표적 현상이라 할 수 있으며, 겨울철 동결융해를 받는 콘크리트는 내부에서 큰 팽창력이 발생되어 콘크리트 균열, 표면 박리, 골재 이탈 등의 파손현상을 보이게 된다. 따라서 이 연구에서는 개발된 차염성 저발열시멘트(CLC)의 동결융해 저항성에 따른 내구성 지수를 알아보기 위해 차염성 저발열시멘트(CLC)와 현재 많이 사용되고 있는 고로슬래그시멘트(BFS), 보통 포틀랜드시멘트(OPC)을 각각 물/시멘트비 35%, 40%, 45% 을 변수로 하여 배합을 실시 하여 공시체를 제작하였다. 제작된 공시체를 KS F 2456(급속동결 융해에 대한 콘크리트의 저항 시험방법)방법에 따라 동결융해 시험을 실시하여 상대 동탄성 계수를 측정하였으며, 측정된 상대동탄성 계수를 가지고 내구성지수를 도출하였다. 내구성 지수를 비교 분석한 결과 차염성 저발열시멘트(CLC), 고로슬래그 시멘트(BFS), 보통 포틀랜드 시멘트(OPC) 모두 우수한 내구성 지수를 나타내는 것으로 확인 되었다.

  • PDF

역설계 기반의 전기자동차 스티어링 기어박스 개발 (Development of the Steering Gear Box for Electric Vehicles based on the Reverse Engineering)

  • 문성식;유영민;유우식
    • 산업공학
    • /
    • 제25권1호
    • /
    • pp.134-141
    • /
    • 2012
  • The steering gear box for mid-heavy duty electric vehicles are usually produced by only a few specialized companies. The special techniques, such as designing, producing and testing technology have been veiled. For this reason, steering gear boxes are imported from other country. The durability test with the electric vehicle which is satisfies the design parameters takes several years, and a prototype is installed in the real vehicle for the test. In this research, the steering gear box of the steering system was developed based on the reverse engineering and the testing methods and the steering gear box development process have been suggested. The prototype is also developed with the CAD and CAE tools. Developed steering gear box have been tested in torque tester and have satisfied requied torque. As a result, the process and testing methods studied in this research are useful in the development processes of electric vehicles steering system.

톤바스트 탐상법(探傷法)에 의한 콘크리트의 균열(龜裂)깊이 측정(測定)에 관한 연구(硏究) (A Study on the Crack Depth Measurements of Concrete by Tone-burst Flaw Detect Method)

  • 한응교;박익근;박준서;이석하
    • 비파괴검사학회지
    • /
    • 제10권1호
    • /
    • pp.73-83
    • /
    • 1990
  • 요즈음 건축물에 설치한 콘크리트의 품질, 신뢰성, 내구성, 균일성 등을 조사하기 위해서 콘크리트의 비파괴 시험에 관한 연구가 부쩍 늘고 있다. 본 논문에서는 초음파가 콘크리트속을 통과할 경우 가장 문제가 되는 것은 감쇠현상인데, 이러한 감쇠를 최소한으로 줄이기 위해서 톤바스트를 이용하였다. 그 결과 균열깊이와 전파시간, 최대출력파워 스펙트럼과 출력전압, 입력주파수와 최대출력 파워스펙트럼의 상관관계는 각각 0.975, 0.847-0.718로 매우 양호함을 알았으며, 톤바스트의 잇점은 이번의 실험에서 수신파 첫동작의 경우 매우 좋았음을 알았다.

  • PDF