• Title/Summary/Keyword: Durability Evaluation

Search Result 951, Processing Time 0.029 seconds

A Study on Standard of Performance Evaluation for Paper Shredder (문서세단기 성능평가방법의 표준화에 관한 연구)

  • 이동규;유송민;이위로;노대호;김민호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.122-127
    • /
    • 2004
  • The purpose of this study is to introduce the standard of the durability and evaluation method for paper shredder. The major evaluation criteria include shredding capability, shredding blade (or cutter) hardness and edge roughness, and durability. Due to the difficulties in assessing the durability directly, performance deterioration of the shredder was assessed by measuring the torque variation along with the variation in shredded chip size and load, thereby proposing the indirect method of assessing the paper shredder durability.

  • PDF

A Study on the Optimization of Field Sampling Number of the Durability Evaluation Method for the Extension Remodeling of the Apartment Housing (공동주택의 증축형 리모델링 안전진단 내구성 평가의 표본 수 최적화 방안 연구)

  • Shin, Heechul;Choi, Kibong;Yoon, Sangchun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.60-68
    • /
    • 2018
  • The Housing Act amended allows vertical extension up to three floors and increases the units of housing (or total floor area) to site up to 15%. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with preliminary investigations on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation methodology for the preliminary investigation is still required because the current procedures are borrowed from safety diagnosis provisions and manuals for reconstruction without detailed examinations on evaluation criteria and sampling methods. Accordingly, this study is intended to suggest a method to obtain feasible sampling size for durability assessment by statistically analyzing the safety evaluation data sets on concrete carbonation and steel corrosion obtained from apartment complexes. The results of this study are expected to be beneficial for establishing more reasonable field sampling size, and in turn, more reliable durability assessment protocol for vertical extension.

Studies on the durability evaluation of the Recycled Cement using Waste Cementitious Powder as Raw material. (폐미분말을 주원료로한 재생시멘트의 내구성능 평가에 관한 연구)

  • Kwon, Eun-Hee;Ahn, Jae-Cheol;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.3-4
    • /
    • 2015
  • Environmental load reduction and sustainable development one of the study's research into the available material is discharged, remove the coarse aggregate and fine aggregate from waste concrete and utilizing the remaining cement fine powder as an alternative raw material for limestone is the main raw material of cement developing playback cement that was the purpose. Physical over existing research and chemical quality was confirmed was evaluated for durability by promoting carbonation test, research studies on the durability evaluation insignificant. As honipyul within the aggregate differential lung fine powder increases carbonation resistance performance've found that increased sharply and, S0 showed fairly similar to the OPC. Therefore, the development within the technology research to separate fine aggregate discharge fully differential and waste fine powder is determined to be the development and use of the playback durability of the cement with the carbonation levels corresponding to the OPC if made.

  • PDF

Durability Evaluation of Grout in Cablebolt System (케이블볼트 충전재의 내구성 평가)

  • Choi, Jung-In;Kim, Won-Keun;Jeon, Jae-Hyun;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.553-561
    • /
    • 2010
  • Like the shotcrete can be deteriorated by chemical compounds as service years increase, the grout which is used to fasten the cablebolt(rockbolt) system in the underground structures also can be deteriorated by chemical compounds such as sulphate and/or chloride contained in groundwater during service years. This can induce issues on the long term durability of cablebolt(rockbolt) system and consequently on the stability of underground structures. In this study, the deteriorations of long term durability of cement mortar grout by each chemical compound of sulphate or chloride are studied experimentally and also complex deterioration by the mix of sulphate and chloride is investigated. Based on the results obtained in this study, the characteristics and prediction of deterioration of long term durability of cement mortar grout for cablebolt(rockbolt) system are suggested.

  • PDF

Durability Evaluation of RC Structures subjected. to Chloride Attack (철근콘크리트 구조물의 염해 내구성 평가)

  • 백승우;남진원;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.663-668
    • /
    • 2003
  • In this paper, an environmental factor and a durability resistance factor which adapts the concept of the Load Resistance Factor Design for safety design of RC structures is derived and a basic principle of a durability evaluation for RC structures using the factors is proposed. It is shown that durability of RC structures can be evaluated by comparing predicted value of chloride ion concentration with limit value of concentration for steel corrosion generation in reinforcement steel position and the durability of concrete manufactured for the RC structures can be also evaluated by comparing characteristic diffusion coefficient of concrete with predicted diffusion coefficient during mixture design.

  • PDF

Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure (수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향)

  • Lim Young-Su;Kim Eun Kyum;Sung Ki Han
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

A Study on Accelerated Life Evaluation Method of Component for Automatic Transmission (자동변속기 구성품의 가속수명평가 방법에 관한 연구)

  • Lim, Hongsoo;Cho, Byungchul;Kim, Yunkyoo;Lee, Heeyong;Kim, Jaehoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.250-256
    • /
    • 2017
  • Automatic transmission(A/T) is one of a car's core components. The durability of A/T has an effect on the durability of the car. The input shaft of A/T passes the power directly from the engine, so the durability of the input shaft for A/T is likewise vital. In this study, the test method of the input shaft is considered and the load spectrum of A/T is analyzed to secure durability of the input shaft. The shape parameter, T-N curve of the input shaft torsional fatigue test are obtained for life evaluation and analysis. Results of this study can be used to get the basic background of the durability test for A/T components.

The Durability Performance Evaluation of Automotive Components in the Virtual Testing Laboratory (차량 부품의 내구성 평가를 위한 가상시험실 구축)

  • Kim, Gi-Hoon;Kang, Woo-Jong;Kim, Dae-Sung;Ko, Woong-Hee;Lim, Jae-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.68-74
    • /
    • 2006
  • The evaluation of durability performance in Virtual Testing Laboratory(VTL) is a new concept of vehicle design, which can reduce the automotive design period and cost. In this study, the multibody dynamics model of a car is built with a reverse engineering design. Hard points and masses of components are measured by a surface scanning device and imported into CAD system. In order to simulate the non-linear dynamic behavior of force elements such as dampers and bushes, components and materials are tested with specialized test equipments. An optimized numerical model for the damping behavior is used and the hysteresis of bush rubber is considered in the simulation. Loads of components are calculated in VTL and used in the evaluation of durability performance. In order to verify simulation results, loads of components in the vehicle are measured and durability tests are performed.

A Durability Evaluation of Remanufactured Industrial Hydraulic Pump and Solenoid Valve (산업용 유압펌프 및 솔레노이드 밸브 재제조품의 내구성 평가)

  • Lee, Kyu-Chang;Park, Sang-Jin;Son, Woo-Hyun;Jeon, Chang-Su;Mok, Hak-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.537-546
    • /
    • 2021
  • Remanufacturing is one of the most important resource recycling technology in response to resource depletion and environmental pollution. Domestic remanufacturing industry don't invigorate compared to other advanced countries because of low price and reliability of remanufactured product. In this study, remanufactured hydraulic pump and solenoid valve were evaluated durability by accelerated life test. In order that standard remanufacturing process was developed by core analysis and failure mode and effect analysis. And cores were remanufactured by standard remanufacturing process. For accelerated life test, the evaluation item and criteria were deduced by results of FMEA, reliability standards and enterprise interior criteria. To evaluate durability of remanufactured product, the remanufactured hydraulic pump and solenoid valve were evaluated performance after accelerated life test and the results were satisfied with criteria. This study showed that remanufactured products have a similar level of durability to new products by definition of remanufacturing.