• Title/Summary/Keyword: Duplicated Errors

Search Result 19, Processing Time 0.023 seconds

Accuracy Improvement of an Automated Scoring System through Removing Duplicately Reported Errors (영작문 자동 채점 시스템에서의 중복 보고 오류 제거를 통한 성능 향상)

  • Lee, Hyun-Ah;Kim, Jee-Eun;Lee, Kong-Joo
    • The KIPS Transactions:PartB
    • /
    • v.16B no.2
    • /
    • pp.173-180
    • /
    • 2009
  • The purpose of developing an automated scoring system for English composition is to score English writing tests and to give diagnostic feedback to the test-takers without human's efforts. The system developed through our research detects grammatical errors of a single sentence on morphological, syntactic and semantic stages, respectively, and those errors are calculated into the final score. The error detecting stages are independent from one another, which causes duplicating the identical errors with different labels at different stages. These duplicated errors become a hindering factor to calculating an accurate score. This paper presents a solution to detecting the duplicated errors and improving an accuracy in calculating the final score by eliminating one of the errors.

DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC (Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구)

  • Lee, Si-Hyuk;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

A Study on the Multistage Screening Procedure when Inspection Errors are Present (검사 오류를 고려한 다단계 선별절차에 관한 연구)

  • Kwon, Hyuck-Moo;Kim, Young-Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.33 no.4
    • /
    • pp.88-95
    • /
    • 2005
  • Multistage screening is a common practice when a component has a critical effect on the function of the assembly. A defect in a component might incur malfunction of an electronic device, resulting in a great amount of loss. Multistage screening, including duplicated screening inspections, may provide a good solution for this problem when inspection errors are present. In the company studied here, the manufacturing process of the multiple layer chip capacitor includes two-stage screening. In the first stage, screening inspection is performed repeatedly until no defects are found in the lot. In the second stage, sampling inspection is performed by a group of experts prior to shipment. In this article, we review the procedure used in the field and suggest a revised model of the multiple screening procedure and solution method for this situation. The usefulness of the proposed model is discussed through a practical example.

Implementation and Fault-tolerance Tests of Load Balanced and Duplicated Active-Active Web Servers (로드 밸런싱 Active-Active 방식의 웹 서버 이중화 구축 및 결함내성 시험)

  • Choi, Jae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2014
  • In this paper we researched on the Duplication Techniques for Active-Active Web Servers. Rsync and crontab utilities make copy periodically between web servers and maintain the same status. Load Balancing Server makes web servers load balanced and fast servicing by executing web servers alternatively. Even though one web server stops due to some critical errors, the remaining web server can take over and provide services continuously.

Corrected equations of motion for a wheel-axle set negotiating an arbitrarily changing radius curve (곡선 경사 선로상 차륜-윤축셋에 대한 수정 운동방정식)

  • Choe, Seong-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.940-952
    • /
    • 2007
  • It is found that there are many serious errors in deriving the existing governing equations of motion for a wheel-axle set negotiating an arbitrarily changing radius curve by Vijay K. Garg and Rao V. Dukkipati. Among other things, despite the hypothesis on arbitrarily changing radius of curve, there had been no taking a time derivative of the radius R in the first half of the derivation. Even if the D'lambert force arising from the centrifugal acceleration of vehicle body or bogie was appropriately taken into account while calculating cant deficiency, it is unnecessarily duplicated in the force vectors of governing equations. The graphical model given in Fig. 5.15 is not enough to follow those developed expressions from both physical and structural points of view. Besides, there are some blunders in assigning plus or minus sign not to be regarded as simple typographic ones and similar mistakes are committed in deriving creep force expressions as in the case of a wheel-axle set on a tangent track.

  • PDF

Full Adjustable Articulator (전조절성 교합기)

  • Yoon, Chang-Keun;Cho, Young-Hak;Ho, Key-Young
    • The Journal of the Korean dental association
    • /
    • v.21 no.10 s.173
    • /
    • pp.793-797
    • /
    • 1983
  • The aim of this article is to review the literature concerning the general aspects of a fully adjustable articulator. A computer can play back when the informations are put into the computer and programmed. A fully adjustable articulator is a computer like device. Even though the fully adjustable articulator is designed precisely, it can not work without inputing the informations and programming into the articulator. That is the reason why various factors controlling the mandibular movements should be recorded and duplicated on articulator avoiding the possible errors.

  • PDF

Foundation Techniques and Fault-tolerance Tests of Active-Active Duplicated Domain Name Servers (Active-Active 방식의 DNS 서버의 이중화 구축 및 결함내성 시험)

  • Choi, Jae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.90-100
    • /
    • 2013
  • Active-Standby Duplication Techniques are conventionally used for fault-tolerant systems. But in this paper we researched on the Active-Active Duplication Techniques for Fault-tolerant DNS System. Our Active-Active Duplication made the 1st DNS periodically copied to the 2nd DNS and maintained the same status by using Rsync and Crontab. Even though the 1st or the 2nd DNS stops due to some critical errors, the remaining DNS can take over and provide continuous services.

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.69-76
    • /
    • 2014
  • Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of interexaminer and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

An Improved Decoding Scheme of LCPC Codes (LCPC 부호의 개선된 복호 방식)

  • Cheong, Ho-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.430-435
    • /
    • 2018
  • In this paper, an improved decoding scheme for low-complexity parity-check(LCPC) code with small code length is proposed. The LCPC code is less complex than the turbo code or low density parity check(LDPC) code and requires less memory, making it suitable for communication between internet-of-things(IoT) devices. The IoT devices are required to have low complexity due to limited energy and have a low end-to-end delay time. In addition, since the packet length to be transmitted is small and the signal processing capability of the IoT terminal is small, the LCPC coding system should be as simple as possible. The LCPC code can correct all single errors and correct some of the two errors. In this paper, the proposed decoding scheme improves the bit error rate(BER) performance without increasing the complexity by correcting both errors using the soft value of the modulator output stage. As a result of the simulation using the proposed decoding scheme, the code gain of about 1.1 [dB] was obtained at the bit error rate of $10^{-5}$ compared with the existing decoding method.

Minimizing the extra-oral time in autogeneous tooth transplantation: use of computer-aided rapid prototyping (CARP) as a duplicate model tooth

  • Lee, Seung-Jong;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The maintenance of the healthy periodontal ligament cells of the root surface of donor tooth and intimate surface contact between the donor tooth and the recipient bone are the key factors for successful tooth transplantation. In order to achieve these purposes, a duplicated donor tooth model can be utilized to reduce the extra-oral time using the computer-aided rapid prototyping (CARP) technique. Materials and Methods: Briefly, a three-dimensional digital imaging and communication in medicine (DICOM) image with the real dimensions of the donor tooth was obtained from a computed tomography (CT), and a life-sized resin tooth model was fabricated. Dimensional errors between real tooth, 3D CT image model and CARP model were calculated. And extra-oral time was recorded during the autotransplantation of the teeth. Results: The average extra-oral time was 7 min 25 sec with the range of immediate to 25 min in cases which extra-oral root canal treatments were not performed while it was 9 min 15 sec when extra-oral root canal treatments were performed. The average radiographic distance between the root surface and the alveolar bone was 1.17 mm and 1.35 mm at mesial cervix and apex; they were 0.98 mm and 1.26 mm at the distal cervix and apex. When the dimensional errors between real tooth, 3D CT image model and CARP model were measured in cadavers, the average of absolute error was 0.291 mm between real teeth and CARP model. Conclusions: These data indicate that CARP may be of value in minimizing the extra-oral time and the gap between the donor tooth and the recipient alveolar bone in tooth transplantation.