• Title/Summary/Keyword: Duodenoscopes

Search Result 3, Processing Time 0.017 seconds

Single Use (Disposable) Duodenoscope: Recent Development and Future

  • Kihyun Ryu;Sunguk Jang
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.191-196
    • /
    • 2022
  • Unlike simple forward-viewing endoscopes such as gastroscope or colonoscope, duodenoscope houses much more complex design to fulfil its function. This design differences leave duodenoscopes more prone to contamination from inadequate disinfection process and potential dissemination of pathogens. Recent reports on dissemination of infection through the duodenoscope mandated an overhaul of duodenoscope utilization including development of a disposable duodenoscope. This article reviews the current state of disposable duodenoscope development, including reported early efficacy as well as its future direction and utilization.

Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis

  • Shivanand Bomman;Munish Ashat;Navroop Nagra;Mahendran Jayaraj;Shruti Chandra;Richard A Kozarek;Andrew Ross;Rajesh Krishnamoorthi
    • Clinical Endoscopy
    • /
    • v.55 no.1
    • /
    • pp.33-40
    • /
    • 2022
  • Background/Aims: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. Methods: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. Results: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%-10.8%, inconsistency index [I2]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%-2.7%, I2=94.96). Conclusions: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted.

Rotatable sphincterotome as a rescue device for endoscopic retrograde cholangiopancreatography cannulation: a single-center experience

  • Takeshi Okamoto;Takashi Sasaki;Tsuyoshi Takeda;Takafumi Mie;Chinatsu Mori;Takaaki Furukawa;Yuto Yamada;Akiyoshi Kasuga;Masato Matsuyama;Masato Ozaka;Naoki Sasahira
    • Clinical Endoscopy
    • /
    • v.57 no.1
    • /
    • pp.96-104
    • /
    • 2024
  • Background/Aims: Selective bile duct or pancreatic duct cannulation remains a significant initial hurdle in endoscopic retrograde cholangiopancreatography (ERCP) despite advances in endoscopy and accessories. This study evaluated our experience with a rotatable sphincterotome in cases of difficult cannulation. Methods: We retrospectively reviewed ERCP cases using TRUEtome, a rotatable sphincterotome, as a rescue device for cannulation at a cancer institute in Japan from October 2014 to December 2021. Results: TRUEtome was used in 88 patients. Duodenoscopes were used for 51 patients, while single-balloon enteroscopes (SBE) were used for 37 patients. TRUEtome was used for biliary and pancreatic duct cannulation (84.1%), intrahepatic bile duct selection (12.5%), and strictures of the afferent limb (3.4%). Cannulation success rates were similar in the duodenoscope and SBE groups (86.3% vs. 75.7%, p=0.213). TRUEtome was more commonly used in cases with steep cannulation angles in the duodenoscope group and in cases requiring cannulation in different directions in the SBE group. There were no significant differences in adverse events between the two groups. Conclusions: The cannulation sphincterotome was useful for difficult cannulations in both unaltered and surgically altered anatomies. It may be an option to consider before high-risk procedures such as precut and endoscopic ultrasound-guided rendezvous techniques.