• 제목/요약/키워드: Dump load

검색결과 25건 처리시간 0.028초

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • 한국지능시스템학회논문지
    • /
    • 제26권5호
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

Passive Transient Voltage Suppression Devices for 42-Volt Automotive Electrical Systems

  • Shen, Z.John
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.171-180
    • /
    • 2002
  • New 42-volt automotive electrical systems can provide significant improvements in vehicle performance and fuel economy. It is crucial to provide protection against load dump and other overvoltage transients in 42-volt systems. While advanced active control techniques are generally considered capable of providing such protection, the use of passive transient voltage suppression (TVS) devices as a secondary or supplementary protection means can significantly improve design flexibility and reduce system costs. This paper examines the needs and options for passive TVS devices for 42-volt applications. The limitations of the commonly available automotive TVS devices, such as Zener diodes and metal oxide varistors (MOV), are analyzed and reviewed. A new TVS device concept, based on power MOSFET and thin-film polycrystalline silicon back-to-back diode technology, is proposed to provide a better control on the clamp voltage and meet the new 42-volt specification. Both experimental and modeling results are presented. Issues related to the temperature dependence and energy absorbing capability of the new TVS device are discussed in detail. It is concluded that the proposed TVS device provides a cost-effective solution for load dump protection in 42-volt systems.

울진1,2호기 출력최적화 및 증기발생기 교체가 주급수 제어계통 안정도에 미치는 영향연구 (Research on a Stability of Feedwater Control System after Stretched Power Uprate and Replacement Steam Generator for Ulchin Units 1&2)

  • 윤덕주;김인환;이재용
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.14-20
    • /
    • 2012
  • Full load rejection capability of nuclear power plant depends primarily on steam dump capacity (SDCAP) and steam generator level control capability. Recently, Ulchin Units 1&2 have performed stretched power uprate (SPU) and replacement steam generator (RSG) projects, which increase the power by 4.5 percent. They change major design or operating parameters and especially reduces steam dump capacity at full power due to increase of the steam flow. The reduction of SDC after SPU results in degradation of heat removal capability in full load rejection transients. Therefore, we should perform evaluation to determine whether reactor trips occur in large load rejection transients. Uchin Units 1&2 have experienced full load rejection (FLR) three times from 2004 to 2010. Operating data from the plant occurrence of FLR at Ulchin Units 1&2 showed that steam generator (SG) level transients were limiting in point of reactor trip. However the plant had never reached reactor trip in the FLR and successfully continued in house load operation. The parameters and setpoints for the SG will be changed if the SG is replaced. Therefore, we evaluated the appropriateness of steam dump, main feedwater and steam generator water level control system preventing the plant from reactor trip in case of FLR by the parameter sensitivity study whether SG water level operated smoothly after SPU and RSG projects.

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

이산요소법을 이용한 벌크 재료 시뮬레이션에 의한 덤프 트럭 데크 하중산출에 대한 연구 (Structural Analysis of the Deck of a Dump Truck Based on Bulk Material Behavior using the Discrete Element Method)

  • 유승훈;우호길
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.187-192
    • /
    • 2020
  • 덤프 트럭 데크의 경량화를 통한 연료 소비를 줄이고 에코 친화적인 설계를 위해서는 정확한 구조 분석이 필요하다. 지금까지 데크의 하중은 정수압 또는 토압 이론을 기반으로 계산되었다. 이 방법으로 데크의 하중 불균일을 계산할 수 없다. 하중 분포는 골재 입자의 크기 분포 및 상호 작용에 따라 달라진다. 이산요소법은 유한요소법보다 효과적으로 골재의 거동을 시뮬레이션할 수 있다. 본 논문에서는 벌크 밀도와 안식각을 측정하여 주요 특성을 얻었다. 15톤 덤프 트럭 데크는 범핑, 브레이킹 및 회전 시의 운동 조건을 적용하여 얻은 하중을 사용했다. 시뮬레이션은 이산요소해석 소프트웨어인 EDEM을 사용했다. 데크의 응력 및 변형 분포는 NASTRAN에 의해 계산되었다. 측정된 값과 비교하였고, 이를 통해 DEM 시뮬레이션의 결과는 수학적 가정에 의한 결과보다 정확함을 확인하였다.

태양열 집열관 과열방지를 위한 지중열교환기 연구 (A study of geothermal heat dump for solar collectors overheat protection)

  • 황현창;;이계복;이석호
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.616-622
    • /
    • 2016
  • 하절기 줄어드는 온수부하는 태양열 집열기 과열의 주된 원인이다. 과열방지목적으로 공냉 또는 차단막이 사용되는데 이는 추가적인 기계적요소를 필요하게 되고 장기 운용 시 파손 등의 우려에 따라 그 신뢰도도 크게 저하된다. 지중열교환기는 지열을 열원으로 방열 또는 흡열을 진행하는데, 지열을 고 열원으로 하여 흡열을 목적으로 하는 연구가 대다수이며 지열원이 저열원으로 이용하는 방열에 대한 연구는 부족한 편이다. 그리하여 본 연구에서는 태양열집열판의 과열방지를 목적으로 하는 지중열교환기의 가능성 및 그 성능에 대한 연구를 진행하였다. 여름철 최대 $150^{\circ}C$이상의 고온을 유지하는 태양열집열판의 열을 방출하기 위하여 1.2m의 하부 깊이를 갖는 50m 나선형 지중열교환기를 설치하였고 이를 통해 순간 냉각이 가능한 것으로 확인되었으며, 태양열집열판의 여름철 과열에 의한 파손을 방지할 수 있었다. 그리고 다양한 변수에 대한 이론적인 계산을 통하여 0.33kg/s의 최저 순환유량만 유지해주면 지열 열교환기의 길이에 따른 방열효과에 큰 영향을 미치지 않음을 판단할 수 있다. 또한 축열조와의 공동 사용시 냉각효과는 여름철 과열시 충분한 과열방지 제어가 가능한 것으로 조사되었다.

Control and Operation of Hybrid Microsource System Using Advanced Fuzzy- Robust Controller

  • Hong, Won-Pyo;Ko, Hee-Sang
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.29-40
    • /
    • 2009
  • This paper proposes a modeling and controller design approach for a hybrid wind power generation system that considers a fixed wind-turbine and a dump load. Since operating conditions are kept changing, it is challenge to design a control for reliable operation of the overall system To consider variable operating conditions, Takagi-Sugeno (TS) fuzzy model is taken into account to represent time-varying system by expressing the local dynamics of a nonlinear system through sub-systems, partitioned by linguistic rules. Also, each fuzzy model has uncertainty. Thus, in this paper, a modem nonlinear control design technique, the sliding mode nonlinear control design, is utilized for robust control mechanism In the simulation study, the proposed controller is compared with a proportional-integral (PI) controller. Simulation results show that the proposed controller is more effective against disturbances caused by wind speed and load variation than the PI controller, and thus it contributes to a better quality wind-hybrid power generation system.

Optimal unidirectional grid tied hybrid power system for peak demand management

  • Vineetha, C.P.;Babu, C.A.
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.47-68
    • /
    • 2016
  • A well designed hybrid power system (HPS) can deliver electrical energy in a cost effective way. In this paper, model for HPS consisting of photo voltaic (PV) module and wind mill as renewable energy sources (RES) and solar lead acid battery as storage device connected to unidirectional grid is developed for peak demand reduction. Life time energy cost of the system is evaluated. One year hourly site condition and load pattern are taken into account for analysing the HPS. The optimal HPS is determined for least life time energy cost subject to the constraints like state of charge of the battery bank, dump load, renewable energy (RE) generation etc. Optimal solutions are also found out individually for PV module and wind mill. These three systems are compared to find out the most feasible combination. The results show that the HPS can deliver energy in an acceptable cost with reduced peak consumption from the grid. The proposed optimization algorithm is suitable for determining optimal HPS for desired location and load with least energy cost.

타이어 모델을 이용한 계측 축중의 보상 방법 (A Method toy Modifying Dynamically Measured Axle Load Using Tire model)

  • 조일수;김성욱;이주형;박종연;이동훈;조동일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.437-437
    • /
    • 2000
  • It is more difficult to accurately weigh vehicles in motion than to weigh standing vehicles. The difficulties in weighing vehicles result from sensor Limitations as well as dynamic effects induced by vehicle/pavement interactions, This paper presents a method for improving the accuracy of measured axle load information using the so-called adaptive footprint tire model. The total vehicle weight as well as individual axle weight information are obtained experimentally using two piezoelectric sensors. Results are obtained for a light car, mid-site passenger car, and 2 dump trucks with known weight experimental results show that the proposed method using the tire model is accurate.

  • PDF