• 제목/요약/키워드: Ductility Factor

검색결과 270건 처리시간 0.026초

연성을 고려한 철근콘크리트 기둥의 강도감소계수 적용에 관한 연구 (An Application of Strength Reduction Factors to Reinforced Concrete Columns considering Ductility)

  • 손혁수;이재훈
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.147-156
    • /
    • 1999
  • Current design code states that the strength reduction factor shall be permitted to be increased linearly from that for axial compression to that for flexure as the design axial load strength $\Phi$cPn decrease from 0.1fckAg to zero. Since this empirically adopted axial load level of $\Phi$cPn=0.1fckAg considers only sectional area and concrete strength, the other variables such as steel ratio, steel yielding strength, and steel arrangement can not be considered. This research is performed to investigate the consistency and the rationality of the code requirement for determination of column design strength. A nonlinear axial force-moment-curvature analysis was conducted in order to investigate the ductility of reinforced concrete column sections. As the result of ductility analysis, it was found that the ductility at the axial force of $\Phi$cPn=0.1fckAg represented a lock of consistency for the various variable contained sections. Therefore, a more reasonable application method of strength reduction factor is proposed, that is based on the strain ductility index.

철골 연성 모멘트 골조의 연성계수 및 강도계수 평가 (Evaluation of Ductility and Strength Factors for Special Steel Moment Resisting Frames)

  • 강철규;최병정
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.793-805
    • /
    • 2004
  • 본 연구에서는 철골 연성 모멘트 골조에 대하여 반응수정계수(R)의 핵심 구성요소인 연성계수 및 강도계수를 평가하였다. 철골 연성 모멘트 골조에 대한 연성계수($R_{{\mu},MDOF}$) 는 단자유도 구조물에 대한 연성계수($R_{{\mu},SDOF}$)에 다자유도 보정계수($R_M$)를 곱하여 산정하였다. 단자유도 구조물에 대한 연성계수($R_{{\mu},SDOF}$)는 지진하중을 받는 탄소성 단자유도(SDOF) 구조물의 목표 변위 연성비와 주기에 따른 비선형 동적해석으로부터 산정하였다. 통계적 연구와 회귀분석으로부터 연성계수를 산정하기 위한 평가식이 제시되었다. 다자유도의 영향을 고려하기 위한 보정계수($R_M$)는 기존의 연구결과로보터 회귀분석을 이용하여 구하였다. 철골 연성 모멘트 골조에 대한 강도계수는 비선형 정적해석으로부터 산정하였다. 철골 연성 모멘트 골조의 연성 계수 및 강도계수를 평가하기 위하여, 구조물의 층수(4, 8 및 16층), 지진구역계수(Z=0.075, 0.2 및 0.4), 골조 시스템(외곽골조 및 분배골조) 및 붕괴 메카니즘(강기둥-약보 및 약기둥-강보)을 설계 매개변수로 하여 총 36개의 예제구조물을 설계하였다. 철골 연성 모멘트 골조의 연성계수 및 강도계수에 이러한 설계 매개변수가 미치는 영향을 분석하였다.

Seismic Design of Structures in Low Seismicity Regions

  • 이동근;조소훈;고현
    • 한국지진공학회논문집
    • /
    • 제11권4호
    • /
    • pp.53-63
    • /
    • 2007
  • Seismic design codes are developed mainly based on the observation of the behavior of structures in the high seismicity regions where structures may experience significant amount of inelastic deformations and major earthquakes may result in structural damages in a vast area. Therefore, seismic loads are reduced in current design codes for building structures using response modification factors which depend on the ductility capacity and overstrength of a structural system. However, structures in low seismicity regions, subjected to a minor earthquake, will behave almost elastically because of the larger overstrength of structures in low seismicity regions such as Korea. Structures in low seismicity regions may have longer periods since they are designed to smaller seismic loads and main target of design will be minor or moderate earthquakes occurring nearby. Ground accelerations recorded at stations near the epicenter may have somewhat different response spectra from those of distant station records. Therefore, it is necessary to verify if the seismic design methods based on high seismicity would he applicable to low seismicity regions. In this study, the adequacy of design spectra, period estimation and response modification factors are discussed for the seismic design in low seismicity regions. The response modification factors are verified based on the ductility and overstrength of building structures estimated from the farce-displacement relationship. For the same response modification factor, the ductility demand in low seismicity regions may be smaller than that of high seismicity regions because the overstrength of structures may be larger in low seismicity regions. The ductility demands in example structures designed to UBC97 for high, moderate and low seismicity regions were compared. Demands of plastic rotation in connections were much lower in low seismicity regions compared to those of high seismicity regions when the structures are designed with the same response modification factor. Therefore, in low seismicity regions, it would be not required to use connection details with large ductility capacity even for structures designed with a large response modification factor.

Response modification factor of dual moment-resistant frame with buckling restrained brace (BRB)

  • Abdollahzadeh, Gholamreza;Banihashemi, Mohammadreza
    • Steel and Composite Structures
    • /
    • 제14권6호
    • /
    • pp.621-636
    • /
    • 2013
  • Response modification factor is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake, in conformity with the point that many seismic design codes led to reduce the loads. In the present paper it's tried to evaluate the response modification factors of dual moment resistant frame with buckling restrained braced (BRB). Since, the response modification factor depends on ductility and overstrength; the nonlinear static analysis, nonlinear dynamic analysis and linear dynamic analysis have been done on building models including multi-floors and different brace configurations (chevron V, invert V, diagonal and X bracing). The response modification factor for each of the BRBF dual systems has been determined separately, and the tentative value of 10.47 has been suggested for allowable stress design method. It is also included that the ductility, overstrength and response modification factors for all of the models were decreased when the height of the building was increased.

An experimental study on the effect of CFRP on behavior of reinforce concrete beam column connections

  • Xie, Qiang;Sinaei, Hamid;Shariati, Mahdi;Khorami, Majid;Mohamad, Edy Tonnizam;Bui, Dieu Tien
    • Steel and Composite Structures
    • /
    • 제30권5호
    • /
    • pp.433-441
    • /
    • 2019
  • The aim of this research is reinforcing of concrete with variety of fiber reinforced polymer (FRP) configurations and investigates the load capacity and ductility of these connections using an experimental investigation. Six scaled-down RC exterior joints were tested under moderately monotonic loads. The results show that, the shape of the FRP had a different effect on the joint capacity and the connection ductility coefficient. The greatest effect on increasing the ductility factor was seen in the sample where two reinforcement plates were used on both sides of the beam web (RCS5 sample). For the sample with the presence of FRP plates at the top and bottom of the beam (RCS3 sample), the ductility factor was reduced even the load capacity of this sample increased. Except for the RCS3 sample, the rest of the samples exhibited an increase in the ductility factor due to the FRP reinforcement.

An investigation of seismic parameters of low yield strength steel plate shear walls

  • Soltani, Negin;Abedi, Karim;Poursha, Mehdi;Golabi, Hassan
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.713-723
    • /
    • 2017
  • Steel plate shear walls (SPSWs) are effective lateral systems which have high initial stiffness, appropriate ductility and energy dissipation capability. Recently, steel plate shear walls with low yield point strength (LYP), were introduced and they attracted the attention of designers. Structures with this new system, besides using less steel, are more stable. In the present study, the effects of plates with low yield strength on the seismic design parameters of steel frames with steel plate shear walls are investigated. For this purpose, a variety of this kind of structures with different heights including the 2, 5, 10, 14 and 18-story buildings are designed based on the AISC seismic provisions. The structures are modeled using ANSYS finite element software and subjected to monotonic lateral loading. Parameters such as ductility (${\mu}$), ductility reduction ($R_{\mu}$), over-strength (${\Omega}_0$), displacement amplification ($C_d$) and behavior factor (R) of these structures are evaluated by carrying out the pushover analysis. Analysis results indicate that the ductility, over-strength and behavior factors decrease by increasing the number of stories. Also, the displacement amplification factor decreases by increasing the number of stories. Finally, the results were compared with the suggestions provided in the AISC code for steel plate shear walls. The results indicate that the values for over-strength, behavior and displacement amplification factors of LYP steel plate shear wall systems, are larger than those proposed by the AISC code for typical steel plate shear wall systems.

Effect of confinement on flexural ductility design of concrete beams

  • Chen, X.C.;Bai, Z.Z.;Au, F.T.K.
    • Computers and Concrete
    • /
    • 제20권2호
    • /
    • pp.129-143
    • /
    • 2017
  • Seismic design of reinforced concrete (RC) structures requires a certain minimum level of flexural ductility. For example, Eurocode EN1998-1 directly specifies a minimum flexural ductility for RC beams, while Chinese code GB50011 limits the equivalent rectangular stress block depth ratio at peak resisting moment to achieve a certain nominal minimum flexural ductility indirectly. Although confinement is effective in improving the ductility of RC beams, most design codes do not provide any guidelines due to the lack of a suitable theory. In this study, the confinement for desirable flexural ductility performance of both normal- and high-strength concrete beams is evaluated based on a rigorous full-range moment-curvature analysis. An effective strategy is proposed for flexural ductility design of RC beams taking into account confinement. The key parameters considered include the maximum difference of tension and compression reinforcement ratios, and maximum neutral axis depth ratio at peak resisting moment. Empirical formulae and tables are then developed to provide guidelines accordingly.

소규모 철근콘크리트 모멘트골조 건축물의 초과강도, 연성도 및 반응수정계수 (Over-Strength, Ductility and Response Modification Factor of Small-Size Reinforced Concrete Moment Frame Buildings)

  • 김태완;추유림;박홍근;신영수
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.145-153
    • /
    • 2016
  • Small-size buildings are not designed by professional structural engineers in Korea. Therefore, their seismic performance can not be exactly estimated because their member sizes and reinforcement may be over- or under-designed. A prescriptive design criteria for the small-size buildings exists, but it also provides over-designed structural members since structural analysis is not incorporated, so it is necessary to revise the prescriptive criteria. The goal of this study was to provide an information for the revision, which is seismic performance and capability of small-size reinforced concrete moment frame buildings. For the study, the state of existing small-size reinforce-concrete buildings such as member size and reinforcement was identified by investigating their structural drawings. Then, over-strength, ductility and response modification factor of the small-size reinforced concrete moment frame buildings were estimated by analytical approach along with seismic performance check. The result showed that they possess moderate over-strength and ductility, and may use slightly increased response modification factor.

Flexural ductility and deformability of reinforced and prestressed concrete sections

  • Au, Francis T.K.;Leung, Cliff C.Y.;Kwan, Albert K.H.
    • Computers and Concrete
    • /
    • 제8권4호
    • /
    • pp.473-489
    • /
    • 2011
  • In designing a flexural member for structural safety, both the flexural strength and ductility have to be considered. For this purpose, the flexural ductility of reinforced concrete sections has been studied quite extensively. As there have been relatively few studies on the flexural ductility of prestressed concrete sections, it is not well understood how various structural parameters affect the flexural ductility. In the present study, the full-range flexural responses of reinforced and prestressed concrete sections are analyzed taking into account the nonlinearity and stress-path dependence of constitutive materials. From the numerical results, the effects of steel content, yield strength and degree of prestressing on the yield curvature and ultimate curvature are evaluated. It is found that whilst the concept of flexural ductility in terms of the ductility factor works well for reinforced sections, it can be misleading when applied to prestressed concrete sections. For prestressed concrete sections, the concept of flexural deformability in terms of ultimate curvature times overall depth of section may be more appropriate.

고층 아파트 구조시스템에 따른 내진성능 분석 (Seismic Capacity according to Structural System of High-rise Apartment)

  • 이민희;조소훈;김종호;김형도
    • 한국전산구조공학회논문집
    • /
    • 제32권3호
    • /
    • pp.149-154
    • /
    • 2019
  • 국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.