• Title/Summary/Keyword: Duct system

Search Result 688, Processing Time 0.03 seconds

Steady-State/Transient Performance Simulation of the Propulsion System for the Canard Rotor Wing UAV during Flight Mode Transition

  • Kong, Changduk;Kang, Myoungcheol;Ki, Jayoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.513-520
    • /
    • 2004
  • A steady-state/transient performance simulation model was newly developed for the propulsion system of the CRW (Canard Rotor Wing) type UAV (Unmanned Aerial Vehicle) during flight mode transition. The CRW type UAV has a new concept RPV (Remotely Piloted Vehicle) which can fly at two flight modes such as the take-off/landing and low speed forward flight mode using the rotary wing driven by engine bypass exhaust gas and the high speed forward flight mode using the stopped wing and main engine thrust. The propulsion system of the CRW type UAV consists of the main engine system and the duct system. The flight vehicle may generally select a proper type and specific engine with acceptable thrust level to meet the flight mission in the propulsion system design phase. In this study, a turbojet engine with one spool was selected by decision of the vehicle system designer, and the duct system is composed of main duct, rotor duct, master valve, rotor tip-jet nozzles, and variable area main nozzle. In order to establish the safe flight mode transition region of the propulsion system, steady-state and transient performance simulation should be needed. Using this simulation model, the optimal fuel flow schedules were obtained to keep the proper surge margin and the turbine inlet temperature limitation through steady-state and transient performance estimation. Furthermore, these analysis results will be used to the control optimization of the propulsion system, later. In the transient performance model, ICV (Inter-Component Volume) model was used. The performance analysis using the developed models was performed at various flight conditions and fuel flow schedules, and these results could set the safe flight mode transition region to satisfy the turbine inlet temperature overshoot limitation as well as the compressor surge margin. Because the engine performance simulation results without the duct system were well agreed with the engine manufacturer's data and the analysis results using a commercial program, it was confirmed that the validity of the proposed performance model was verified. However, the propulsion system performance model including the duct system will be compared with experimental measuring data, later.

  • PDF

The Control Performance of the Active Control System with Insufficient Number of Control Sources and Sensors for the Reduction of Duct Noise (고차모드 수보다 적은 수의 제어음원과 센서를 이용한 덕트 방사소음 제어시스템의 제어성능)

  • 윤두병;김양한;정균양;조대승
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1030-1036
    • /
    • 1998
  • When the lateral dimensions of a duct is larger than or comparable to the wavelengths of Interest, higher order modes propagate in the duct. These modes will be radiated and produce noise. A number of sensors and actuators for control of radiating noise from the duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and control sources than required. In this work, by theoretical analysis, the control performance of such a kind of system is investigated in terms of sound-field variables and control system variables. The possible maximum and minimum value. mean and variance of residual acoustic potential energy are derived for the set of primary sound fields.

  • PDF

Active Control of Sound in a Duct System by Back Propagation Algorithm (역전파 알고리즘에 의한 덕트내 소음의 능동제어)

  • Shin, Joon;Kim, Heung-Seob;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2265-2271
    • /
    • 1994
  • With the improvement of standard of living, requirement for comfortable and quiet environment has been increased and, therefore, there has been a many researches for active noise reduction to overcome the limit of passive control method. In this study, active noise control is performed in a duct system using intelligent control technique which needs not decide the coefficients of high order filter and the mathematical modeling of a system. Back propagation algorithm is applied as an intelligent control technique and control system is organized to exclude the error microphone and high speed operational device which are indispensable for conventional active noise control techniques. Furthermore, learning is performed by organizing acoustic feedback model, and the effect of the proposed control technique is verified via computer simulation and experiment of active noise control in a duct system.

Anatomic and radiographic studies of the lacrimal drainage system in Korean native goat (한국재래산양 코눈물관계통의 해부학적 및 방사선학적 연구)

  • Seo, Kang-moon;Kang, Tae-cheon;Lee, Heungshik S;Lee, In-se;Nam, Tchi-chou
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.1
    • /
    • pp.23-29
    • /
    • 1996
  • This study was carried out to identify the gross anatomical and radiographic characteristics of the nasolacrimal system of the Korean native goat. The results were as follows : The nasolacrimal system are composed of two lacrimal ducts, two lacrimal, canaliculus, one lacrimal sac and one nasolacrimal duct. The nasolacrimal duct was divided into proximal, middle and distal portion. The nasolacrimal duct took a straight course to be paralleled with nasal bones and opened close to the nostril on the medial surface of the alar fold. The diameter of lacrimal punctum, the length of eyelid margin to lacrimal punctum, the length of canaliculus and the diameter of lacrimal sac were 0.82~0.90mm, 1.06~1.54mm, 5.65~6.30mm and 1.77~2.06mm, respectively. The length of proximal, middle and distal nasolacrimal duct were 36.84~40.00mm, 23.53~24.31mm and 14.55~14.73mm, respectively. The diameter of the orifice of nasolacrimal duct, the length of lateral margin of nostril to orifice of nasolacrimal duct and the length of dorsum to orifice of nasolacrimal duct were 1.29~1.33mm, 12.97~12.53mm and 15.24~16.11mm. The skull index of Korean native goat was not significantly different from the length of nasolacrimal duct.

  • PDF

An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System (환기팬 시스템의 소음특성과 저감에 관한 실험적 연구)

  • Kim, Deok-Han;Lee, Dong-Hoon;Kwon, Hyuk-Jung;Kim, Dong-Yun;Lee, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

Development of Cabin Noise Prediction Program Induced by HVAC System (공조시스템 유기 격실 소음 예측 프로그램 개발)

  • Kim, Byung-Hee;Kwon, Jong-Hyun;Cho, Dae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

The Comparative Experiment of Duct Design Method with Equal Friction Loss Method and T-Method on a House Ventilation System (등압법과 T-Method법을 이용한 주택환기시스템 덕트설계법의 비교실험)

  • Joo, Sung-Yong;Kim, Kwang-Hyun;Choi, Seok-Yong;Yee, Jurng-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.99-104
    • /
    • 2006
  • Accurate flow rate distribution has been become a very important part for controling of air change rate since the introduction of house ventilation system. An inappropriate selection of fan due to Incorrect prediction of friction loss makes waste energy. The purpose of this study is to recognize applicability of T-Method at house ventilation system by comparing experiment with T-method, The result of this study is as follows Flow rate is small amount in a house, so duct size must be accurate. And duct design with Equal Friction Loss Method presented large error range. Equal friction loss method is not fit to applicate small amount air flow rate. T-Method predicts accurate flow rate comparatively in a house ventilation system. Error range was 3.5%.

  • PDF

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례)

  • 김철홍;주영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

An Experimental Study on the Application of Horizontal Daylight Duct System in Building Interior Space (실내 건축공간에 있어 수평채광덕트 시스템의 적용에 관한 실험적 연구)

  • 이성주;김회서
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this paper was development of modified horizontal daylight duct for reflector of light intake, location of outlet diffuser and size as applicable daylighting system for buildings and, verified applicable possibility base on analysis of daylighting performance through full-scale model test. Experimental result showed that ratio of illumination for light duct was measured 0.3∼0.4% in interior of a room on clear sky. Also, light duct had wide distribution of illumination than duct about 150[cm] and was decided efficient lighting energy saving because of high daylight performance in case of application actual building during daytime.

A study on the noise reduction of practical duct system with the air cavity (공기층을 갖는 실제덕트 구조물에서의 소음저감에 관한 연구)

  • Kim, Chan-Mook;Lee, Doo-Ho;Bahng, Keuk-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1687-1692
    • /
    • 2000
  • In this paper, experimental methods to find acoustic characteristics of acoustically treated air-conditioning duct system are proposed. Existing methods to analyze acoustic properties of duct with absorbent material have a dilemma which has to assume the wave in duct to be a plane wave. Under this assumption, applicable frequency limitation makes accurate analysis of practical air-conditioning system impossible. In order to analyze the properties of in-lined treated absorbent with high degree of accuracy, in this experiments the range of exciting frequency of sound source is broadband, which means that source speaker excites higher mode of in-duct sound field. Also, to define the relations of air cavity to the acoustic characteristics, acoustic experiments on ducts with air cavity of different depth are operated. In conclusion, air-cavity makes the absorbing ability of duct improved in low frequency range. Due to the interactions between the air cavity depth and the depth of absorbents, according to depth of cavity, the magnitude of absorption coefficients vs frequencies in specific range is changed. In lower frequency range, the absorption of sound energy by air cavity is more dominant than by absorbent itself, in higher range, the inversion is true.

  • PDF