• Title/Summary/Keyword: Duct size

Search Result 181, Processing Time 0.028 seconds

A Clinical Experience of Nasopalatine Duct Cyst with Bony Defect (골결손을 동반한 비구개관 낭종의 치험례)

  • Kim, Young-Jin;Seo, Je-Won;Jun, Young-Joon;Kim, Sung-Sik
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.255-258
    • /
    • 2005
  • The nasopalatine duct cyst, known as the incisive canal cyst, is the most common nonodontogenic cyst in the maxillofacial area. It is believed to arise from epithelial remnants of the embryonic nasopalatine duct. Nasopalatine duct cysts are most often detected in patients between forties and sixties. The trauma, bacterial infection, or mucous retention has been suggested as etiological factors. The cysts often present as asymptomatic swelling of the palate but can present with painful swelling or drainage. Radiologic findings include a well demarcated cystic structure in a round, ovoid or heart shape presenting with a well-defined bone defect in the anterior midline of the palate between and posterior to the central incisors. Most of them are less than 2cm in size. On MRI, the cyst is identified as a high-intensity, well-marginated lesion, which indicates that it contains proteinaceous material. We experienced a case of a 61-year-old female patient who had a $2.3{\times}2.6{\times}1.7cm$ sized nasopalatine duct cyst. The bony defect after a surgical extirpation was restored with hydroxyapatite. So we report a good results with some reviews of the literatures.

An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber (덕트형 세정집진기의 입자포집 특성실험)

  • Yoo, Kyung-Hoon;Yeo, Kuk-Hyun;Son, Seung-Woo;Hwang, Kwang-Ho;Jung, Jin-Won;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

The Comparative Experiment of Duct Design Method with Equal Friction Loss Method and T-Method on a House Ventilation System (등압법과 T-Method법을 이용한 주택환기시스템 덕트설계법의 비교실험)

  • Joo, Sung-Yong;Kim, Kwang-Hyun;Choi, Seok-Yong;Yee, Jurng-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.99-104
    • /
    • 2006
  • Accurate flow rate distribution has been become a very important part for controling of air change rate since the introduction of house ventilation system. An inappropriate selection of fan due to Incorrect prediction of friction loss makes waste energy. The purpose of this study is to recognize applicability of T-Method at house ventilation system by comparing experiment with T-method, The result of this study is as follows Flow rate is small amount in a house, so duct size must be accurate. And duct design with Equal Friction Loss Method presented large error range. Equal friction loss method is not fit to applicate small amount air flow rate. T-Method predicts accurate flow rate comparatively in a house ventilation system. Error range was 3.5%.

  • PDF

The Effects of Operational Factors On the Performance of Husk Separator (왕겨풍구의 성능(性能)에 영향(影響)을 미치는 작동요인(作動要因)에 관(關)한 연구(硏究))

  • Chang, Hyun Taik;Noh, Sang Ha;Chung, Chang Joo
    • Journal of Biosystems Engineering
    • /
    • v.9 no.1
    • /
    • pp.22-33
    • /
    • 1984
  • Husk separator is an indispensable equipment in rice milling plants. However, any basic research on the designing and operating criteria of the husk separator have rarely been conducted in Korea. According to the survey results reported recently, grain loss occurs in the process of rice husk separation at custom rice milling plants in Korea and the performance of husk separator has also not been identified. With this regard this study was conducted with a typical commercial husk separator to investigate the effect of the operational factors such as feed rate, blower speed and opening ratio on the velocity distribution in the air duct and the performance of the separator. The results are summerized as follows: 1. The average wind velocity in the primary air duct increased linearly with the blower rpm and the size of air inlet port in both cases of double type and single type operations. 2. The coefficient of variation in the horizontal wind velocities in the primary air duct was the minimum when the opening ratio was 0.22 ($0.052m^2$ of air inlet port) in both cases of single type and double type operations regardless of the blower speeds used in this test. The average wind velocity at the upper part of air duct was greater by 2-5 m/s than the velocity at the bottom part in double type operation. In case of single type operation, however, the average velocity in the middle part was greater than the upper or bottom part when the opening ratio was greater than 0.74. 3. The relationship between the overall effectiveness of separation(Ed for double type and Es for single type) and the average wind velocity (Va) in the primary air duct was expressed in the following quadratic functions. $$Ed=-190.84+106.18Va-10.052Va^2$$ ($r^2$ = 0.97782) $$Es=-223.76+106.23Va-9.1935Va^2$$ ($r^2$ = 0.97029) The average wind velocity required to obtain the overall effectiveness of separation more than 80% ranged from 4.04 m/sec to 5.84 m/sec in case of double type operation, and from 4.70 m/sec to 6.20 m/sec in case of single type. 4. An optimum wind velocity can be obtained with an increase in the blower speed or the size of air inlet port as presented in Figure 8. There was a tendency that the faster the blower speed, the narrower the control range of the air inlet port. 5. The feed rates (1850kg/hr and 2100kg/hr) adopted in this experiment did not bring about a significant difference in both the overall effectiveness of separation and the power consumption. 6. The energy consumption increased cubically with the blower speed but linearly with the size of the air inlet port. On the basis of the results described in items 1, 3, and 6, it would be more economic to adjust the size of the air inlet port larger with a relatively low blower speed than to adjust the size smaller with a relatively high speed.

  • PDF

Fine Structure of Salivary Gland in Korean Slug (Incilaria fruhstorferi) (한국산 산민달팽이 (Incilaria fruhstorferi) 타액선의 미세구조)

  • Chang, Nam-Sub;Han, Jong-Min
    • Applied Microscopy
    • /
    • v.26 no.3
    • /
    • pp.305-313
    • /
    • 1996
  • Acinous gland cells (A, B, C, D and E-type cells) and duct cell (G-type cell) are observed in acinus and in duct of salivary gland of Korean Slug respectively by electron microscope. The type-A gland cells are numerous and are packed with medium electron dense granules (diameter, $3{\mu}m$) in cytoplasm. The circular shaped nucleolus and evenly developed chromatins are observed in the nucleus of type-B cell, and cytoplasm includes medium electron dense granules (diameter, $2.5X3.7{\mu}m$). The type-C gland cell has a round nucleus, and thin elongated-shaped heterochromatins are evenly distributed in the nucleoplasm and many net shaped endoplasmic reticulums and oval serous granules of middle electron density (diameter, $3.5X5{\mu}m$) fill the cytoplasm. The type-D gland cell is the largest and the most numerous of the gland cells consisting the salivary gland and heterochromatins in nucleus are well developed in the nucleoplasm. Most of granules (diameter, $0.8X2.5{\mu}m$) in cytoplasm are round, and look dark for the high electron density, and cytoplasm is filled with net-shaped endoplasmic reticulums. The type-E gland cells are rarely existent around the salivary gland, and the granules of those cells are irregular in shape and size and are vacuolized in cytoplasm. Intralobular salivary duct is composed of the high electron dense squamus endotheliums, while the other interlobular salivary duct is filled with irregular columnar epitheliums. The interlobular duct cell contains the high electron dense granules (size, $0.3{\sim}1.5{\mu}m$) in cytoplasm and those granules are secreted into cilia of salivary lumen.

  • PDF

A New LMS Algorithm for Improved Convergence Time in Active Noise Control (수렴속도 개선을 위한 새로운 LMS 알고리즘)

  • Park, Kyoung-Ho;Kim, Il-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.3
    • /
    • pp.276-279
    • /
    • 2001
  • Many industrial processes that are operated by rotating machines and large air-moving fans are excellent examples to which the single channel ANC systems can be applied. In these environments, the active noise control techniques are most popular nowadays. In this paper, a modified LMS algorithm(EAC, Error Amplitude Compared) is proposed. The algorithm is a kind of variable step-size LMS-type algorithm. Computer simulations show that the proposed EAC algorithm achieves a better convergence time than a conventional VS(Variable Step-Size) algorithm, Also, this algorithm has been implemented by using and experimental duct system.

  • PDF

An Experimental Investigation of Noise Reduction by Blades in a Duct (회전 날개에 의한 덕트 소음 저감에 관한 실험적 고찰)

  • 최성배;이재곤
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.5
    • /
    • pp.357-363
    • /
    • 2003
  • There have been lots of studies on noise transmission analysis and noise reduction In ducts. In order to reduce the noise transmission in ducts. active noise cancellation techniques have often been employed and a rotation shaft with blades has sometimes been suggested. These Ideas were not successfully commercialized because of the limitation of real life such as size or application difficulties. This study investigated how a rotational shaft with blades could reduce the noise transmission in a duct. To do so, an assembly of the shaft and the $haft housing was built In the middle of a duct. and the clearance between the blades and the housing was 0.2 mm. The noise reduction was experimentally evaluated with respect to the number of blades. the rotation speed, and the rotation or stop. This paper showed that the noise reduction resulted in about 14∼19 dBA regardless of the three test conditions only If the blades always blocked the duct. And. the noise reduction increased due to the higher number of blades and the lower speed of the shaft.

Treatment of intractable parotid sialocele occurred after open reduction-fixation of mandibular subcondylar fracture

  • Hwang, Jungil;You, Yong Chun;Burm, Jin Sik
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.157-161
    • /
    • 2018
  • A sialocele is a subcutaneous cavity containing saliva, most often caused by facial trauma or iatrogenic complications. In subcondylar fractures, most surgeons are conscious of facial nerve injury; however, they usually pay little attention to the parotid duct injury. We report the case of a 41-year-old man with a sialocele, approximately $5{\times}3cm$ in size, which developed 1 week after subcondylar fracture reduction. The sialocele became progressively enlarged despite conservative management. Computed tomography showed a thin-walled cyst between the body and tail of the parotid gland. Fluid leakage outside the cyst was noted where the skin was thin. Sialography showed a cutting edge of the inferior interlobular major duct before forming the common major duct that seemed to be injured during the subcondylar fracture reduction process. We decided on prompt surgical treatment, and the sialocele was completely excised. A duct from the parotid tail, secreting salivary secretion into the cyst, was ligated. Botulinum toxin was administrated to block the salivary secretion and preventing recurrence. Treatment was successful. In addition, we found that parotid major ducts are enveloped by the deep lobe and extensive dissection during the subcondylar fracture reduction may cause parotid major duct injury.

Computational Analysis of KCS Model with an Equalizing Duct

  • Ng'aru, Joseph Mwangi;Park, Sunho;Hyun, Beom-soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.247-256
    • /
    • 2021
  • In order to minimize carbon emissions and greenhouse gas, the Energy Efficiency Design Index (EEDI) has become a major factor to be considered in recent years in a ship's design and operation phases. Energy-Saving Devices (ESDs) improve the EEDI of a vessel and make them environmentally friendly. In this research, the performance of an equalizing duct-type ESD installed upstream of a Korea Research Institute of Ships & Ocean Engineering (KRISO) Container Ship (KCS) model's propeller was investigated by computational fluid dynamics (CFD). Open-source CFD libraries, OpenFOAM, were used for computational analysis of the KCS with and without the ESD to verify the performance improvement. The flow field near the stern region and propulsive coefficients were considered for comparison. The results showed a considerable improvement when an ESD was used on the model. Using different sizes of the duct, the performance of the ESD was also compared. It was observed that with an increased duct size, the propulsive performance was improved.

A Case Report on Recurrent Salivary Duct Carcinoma Treated with Casodex/Nolvadex and Traditional Korean Medicine (Casodex/Nolvadex와 한방치료를 병행하여 호전된 재발성 침샘관암 환자 1례)

  • Yang, Jung-min;Jang, Kwon-jun;Ko, Eun-bi;Lee, Ji-yoon;Yoon, Min-ji;Jo, On-you;Jeong, Seong-heon;Moon, Hyang-ran;Shin, Kwang-soon;Hwang, Woo-seok
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.1062-1073
    • /
    • 2021
  • Objectives: This study examined the case of a patient with recurrent salivary duct carcinoma and hepatic metastasis. Methods: The patient was treated with Casodex/Nolvadex from January 25th 2021 onward with doses of bicalutamide (150 mg/day) and tamoxifen (10 mg/day) every four weeks. Simultaneously, the patient was treated with Korean medicine. The tumor size was measured using computed tomography (CT). Adverse events were evaluated according to the National Cancer Institute's Common Terminology Criteria for Adverse Events (NCI-CTCAE), version 5.0. Results: Following the four-month treatment, the extent of the proximal portion of hepatic metastasis decreased, and discomfort and physical activity gradually improved. Conclusions: The results suggest that combined chemotherapy and Korean medicine may help to reduce tumor size and improve quality of life.