• Title/Summary/Keyword: Duct flow

Search Result 793, Processing Time 0.032 seconds

CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector (사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석)

  • Koo, Seongmo;Oh, Wonchul;Chang, Hyuksang
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

A Study on the Influence of S Shaped Annular Duct on the Centrifugal Compressor Performance (S자형 환형덕트가 원심압축기 성능에 미치는 영향에 관한 연구)

  • 정주현;전승배;김승우
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.64-73
    • /
    • 1998
  • In twin spool aero-engine, there may be a S shaped annular duct between high pressure and low pressure spools. The flow passing this S shaped duct experiences the flow acceleration and deceleration due to the convex and concave surface of the duct as well as the increase of blockage according to the boundary layer growth along the surfaces. So, the high pressure compressor which is located behind the S shaped duct is influenced by the non-uniform flow field generated by the geometry of inlet duct. To study the influence of the S shaped duct on the centrifugal stage, performance tests were implemented for the compressor with straight cylindrical inlet duct and with S shaped inlet duct, respectively. The test results showed that the performance, such as pressure ratio and efficiency, of the compressor with S shaped duct was worse than that of the compressor with cylindrical duct. And the compressor with S shaped duct had reduced maximum flow rate around design speed. To investigate the cause of performance degradation, flow anlaysis was performed for the impeller in front of which is located S shaped annular duct. The result of CFD showed the strong acceleration of the flow in the axial direction around the inducer tip region which caused the increase of relative mach number and the decrease of incidence angle of the flow.

  • PDF

A Study on Flow Characteristics of the Inlet Shape for the S-Duct (S-Duct 입구 형상에 따른 유동 특성에 관한 연구)

  • Lee, Jihyeong;Choi, Hyunmin;Ryu, Minhyoung;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Aircraft needs an inlet duct to supply the airflow to engine face. A fighter aircraft that requires low radar observability has to hide the engine face in the fuselage to reduce the Radar Cross Section(RCS). Therefore, the flow path of the inlet duct is changed into S-shape. The performance of the aircraft engine is known to be influenced by the shape and the centerline curvature of the S-Duct. In this study, CFD analysis of the RAE M 2129 S-Duct has been performed to investigate the influence of aspect ratio of inlet geometry. The performance of the S-Duct is evaluated in terms of the distortion coefficient. To simulate the flow under adverse pressure gradient better, $k-{\omega}SST$ turbulence model is employed. The computational results are validated with the ARA experimental data. The secondary flow and the flow separation are observed for all computational cases, while the semi-circular geometry has been found to produce the best results.

Effects of Outflow Boundary Conditons and Turbulent Models on an S-duct Flow (S-duct 내부유동의 출구경계조건 및 난류모텔의 영향검토)

  • Hong S. K.;Lee K. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.120-126
    • /
    • 2000
  • An S-duct flow is subjected to an entrance flow of Mach 0.6. The duct turns $30^{\circ}$ and reverses its turn by $30^{\circ}$ followed by a straight section. Such an internal flow induces a secondary flow due to curvature effect. Goal of this paper is to show the sensitivity of outflow boundary conditions on the quality of numerical solutions as well as to show curvature effect on the flow field. The often-used Baldwin-Lomax turbulence model is shown to be less functional on the concave region when the secondary flow has its strong Influence.

  • PDF

A Study on Velocity Profiles and Critical Dean Number of Developing Transitional Unsteady Flows in a Curved Duct (곡관덕트의 입구영역에서 천이비정상유동의 속도분포와 임계딘수에 관한연구)

  • 이행남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.862-870
    • /
    • 1998
  • In this paper an experimental investigation of characteristics of developing transitional unsteady flows in a square-sectional 180。 curved duct are presented. The experimental study using air is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Do ppler Velocimeter(LDV) system. The flow development is found to depend upon Dean number dimensionless angular frequency velocity amplitude ration and cur-vature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows are strong and complicate at entrance region. The entrance length of transitional pulsating flow is obtained to 120。 of bended angle of duct in this experimental conditions.

  • PDF

Improvement of Maldistributed Air Velocity in the Vane Wheel of a Bowl Type Pulverizer (바울형 미분기 베인휠에서의 유속 불균일 개선에 관한 연구)

  • Park, Deok-Bae;Hur, Jin-Huek;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.2
    • /
    • pp.62-69
    • /
    • 2010
  • The stability of coal pulverizer in the 800 MW coal-fired plants is vital to maintain their performance. Thus, this study analyzed the uneven abrasion of the deflector and coal spillage due to the air velocity maldistribution in the vane wheel of a bowl-type pulverizer as it is a possible cause for problems of facility using pulverized coal. In addition, air flow in the underbowl of a bowl-type pulverizer was studied to check air velocity maldistribution in the vane wheel using numerical method. In an attempt to correct the maldistribution of air velocity, air flow of the modified duct vane was studied as enlarging the length of the duct vanes installed at the air inlet duct of the pulverizer and increasing the angle of inclination. It was found that modified duct vane make the velocity distribution at the vane wheel uniform. formed by the duct vanes installed at the air inlet duct of the pulverizer and swirling flow is the major factor in making the velocity distribution of vane wheel exit uniform. This can prevent the uneven abrasion of the deflector, which is one of the components inside the pulverizer and coal spillage.

  • PDF

A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method (등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구)

  • Park, Joon-Suk;Choi, Gil-Hwan;Cho, Dae-Seung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.4
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

NUMERICAL SIMULATION OF INCOMPRESSIBLE LAMINAR ENTRY FLOWS IN A SQUARE DUCT OF $90^{\circ}$ BEND BY UNSTRUCTURED CELL-CENTERED METHOD (비정렬 셀 중심 방법에 의한 정사각형 단면을 갖는 $90^{\circ}$ 곡관 층류유동의 수치해석)

  • Myong H. K.;Kim J. E.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.81-85
    • /
    • 2005
  • Three-dimensional steady incompressible laminar entry flows in a square duct of $90^{\circ}$ bend are numerically simulated by a new solution code(PowerCFD) using unstructured cell-centered method. Solutions are obtained with three unstructured grid types of hexahedron, prism and hybrid at a Reynolds number, based on the hydraulic diameter and bulk velocity, of 790. Interesting features of the flow are presented in detail. Detailed comparisons between the computed solutions and the available experimental data are given mainly for the velocity distributions at cross-sections in a $90^{\circ}$ bend of a square duct with fully-developed entry flows. It is found that the code is capable of producing the nature of laminar flow in curved square duct with no grid type dependency.

  • PDF

The comparison between Numerical Computation and Experiment on Fluid Elow in Rectangular Duct (사각덕트내의 유체유동에 관한 수치계산과 실험의 비교)

  • Yoon Young-Hwan;Bae Taeg-Hee;Park Won-Gu
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.71-74
    • /
    • 2002
  • Fluid flow in a rectangular duct system are measured by W laser doppler velocity meter, and also computed by commercial software of STAR-CD for comparison between then First, for a rectangular duct with 90 degree metered elbow, the fluid flow with Reynolds numbs's of 1,508 is predicted by assumption of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300-3,000, the computation by turbulent model is close to the experimental data. Moeover, the computation by turbulent model for Reynolds number of 11,751 also predicts the experimental data satisfactorily. Second, for a rectangular duct with two branch ducts, the ratios between flow rates in the two branches are invariant to Reynolds number according to both of numerical and experimental results.

  • PDF

A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester (덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구)

  • Lee Seung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.