• Title/Summary/Keyword: Duct area

Search Result 233, Processing Time 0.027 seconds

An Analysis of Deaths Caused by Cancer in Metropolitan Areas of Korea - Seoul, Pusan, Taegu, Incheon - (우리나라 대도시지역 암 사망자에 대한 분석 -서울, 부산, 대구, 인천을 중심으로-)

  • Lee, Chae-Un;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.1 s.21
    • /
    • pp.84-96
    • /
    • 1987
  • For the purpose of preparing the basic data for further cancer epidemiologic study and cancer patients control, we conducted the analysis on the degree and structure of deaths from cancer in metropolitan areas of Korea with 7,934 certified cancer deaths records of Seoul, Pusan, Taegu and Incheon in 1982. The analyzed results were as follows: 1) The total number of cancer deaths in metropolitan areas were 7,934 (male: 4,749, female: 3,185) as 14.1% of deaths from all causes in the same area. 2) The rate of physician's certification on cancer deaths was 77.4% and most of cancer deaths (84.4%) occured at their home. 3) Cancer specific death rate was 51.7 per 100.000 population (male: 62.9, female: 41.9) and age-adjusted cancer death rate was 82.4 in male and 51.6 in female per 100,000 population. And the difference was statistically significant (p< 0.01). 4) Age-specific cancer death rate was generally increased with age and most of cancer deaths (male: 75% , female: 65%) occurred from 45 to 74 years old. 5) The first three orders of cancer site were stomach (32.7%), liver (28.8%), lung (11.7%) in male and stomach (30.6%), uterus (18.4%), liver (13.8%) in female. And the relative frequency of these three cancer sites among total cancer deaths was corresponded to 73.2% in male and 62.8% in female. 6) The ratio of male to female cancer death rate was 1.5:1. And the ratio was aboye 3.0 in esophagus, liver, larynx, bladder cancer and the ratio was similar to 1.0 in stomach, pancreas, leukemia, brain, colon cancer, but the ratio was reversed in gall bladder and bile duct, and thyroid cancer.

  • PDF

Diagnostic Evaluation of Serum FSH and LH in Primary Amenorrhea by Radioimmunoassay (방사성 면역측정상의 혈청 FSH와 LH에 관한 일차성 무월경증 환자의 진단적 고찰)

  • Hong, I.S.;Kim, G.E.;Yoo, H.S.;Lee, J.T.;Park, C.Y.;Ryu, K.J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.37-44
    • /
    • 1980
  • The usefulness of single, random measurements of serum FSH and LH in the diagnosis of primary amenorrhea by radioimmunoassay was investigated. The 16 patients were divided into 3 groups by the level of serum FSH and LH. The first group with increased level of serum FSH and LH is five patients, all of these are related to the acquired or congenital abnormality of the ovary. Further studies indicated include buccal smear, chromosome analysis, gynecography and laparosocopy. The second group with normal serum FSH and LH is nine patients, four patients of these are related to the developmental anomaly of the Mullerian duct and five patients are undo etermined origin. Further studies indicated include laparoscopy and gynecography. The third group with decreased serum FSH and normal or decreased serum LH is two patients, one of these is related to the pituitary function, isolated FSH deficiency, the other is undetermined origin. Further studies indicated include the pituitary function test, LH-RH stimulation test, skull radiography. Determination of serum FSH and LH levels does not permit a specific etiologic diagnosis of primary amenorrhea. However the serum levels of FSH and LH can be used to differentiate the principal area of the investigation and can be of assistance in choosing more specific testing procedures.

  • PDF

A Preliminary Study on the Construction or the AM/FM System for a Univesity (대학 시설물관리시스템 구축에 관한 기초적 연구)

  • 안기원;이효성;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.277-286
    • /
    • 1997
  • The purpose of this study is to construct the AM/FM system for a university. The sample area used in this study is the Gyeongsang National University in Chinju City, Korea. The layout maps, which scale are 1/1200, 1/3000 and 1/5000, a map of planning of common duct, which scale is 1/1200, and the facility maps which scale is 1/200 were used for input of spatial data. The year of pipe buried, materials of pipe, pipe diameter, length of pipe, depth of pipe buried and slope of pipe buried were purpose of efficient data searching, analyzing, and processing. It was revealed that rapid providing of facility informations and efficient facility management are possible using the constructed the AM/FM system for a university.

  • PDF

Design Optimization for Air Ducts and Fluid Pipes at Electromagnetic Pulse(EMP) Shield in Highly Secured Facilities (EMP 방호시설의 덕트 및 배관 최적 설계 방안)

  • Pang, Seung-Ki;Kim, Jae-Hoon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.4
    • /
    • pp.15-24
    • /
    • 2014
  • This study conducted a computational fluid dynamics(CFD) analysis to find an appropriate diameter or sectional area of air ducts and fluid pipes which have an electromagnetic pulse(EMP) shied to protect indoor electronic devices in special buildings like military fortifications. The result shows that the optimized outdoor air intake size can be defined with either the ratio of the maximum air velocity in the supply duct to the air intake size, or the shape ratio of indoor supply diffuser to the outdoor air intake. In the case of water channel, the fluid velocity at EMP shield with the identical size of the pipe, decreases by 25% in average due to the resistance of the shield. The enlargement of diameter at the shield, 2 step, improves the fluid flow. It illustrated that the diameter of downstream pipe size is 1step larger than the upstream for providing the design flow rate. The shield increases friction and resistance, in the case of oil pipe, so the average flow velocity at the middle of the shield increase by 50% in average. In consideration of the fluid viscosity, the oil pipe should be enlarged 4 or 5 step from the typical design configuration. Therefore, the fluid channel size for air, water, and oil, should be reconsidered by the engineering approach when EMP shield is placed in the middle of channel.

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

A Comparative Study on Domestic and Foreign Standards for Air Supply for the Improvement of a Smoke Control System for High-Rise Buildings (국내 고층건축물의 제연설비 성능 개선을 위한 국내·외 급기량 관련 기준 비교연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Lee, Su-Gak;Kim, Jung-Yup;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In South Korea, smoke control systems are designed according to the fire safety standards NFSC501 and NFSC 501A. However, there is a problem in that the design values are incompatible when measuring the performance of the system after the design construction for calculating the leakage crack area described in the standards. Therefore, we compared the standards for smoke control systems from South Korea, Japan, and the United Kingdom. In South Korea, designs are conducted uniformly according to the NFSC 501A Manual, but in Japan and the United Kingdom, designs consider smoke temperature, duct loss, and fire floor air supply. Furthermore, they use larger values than in South Korea.

Experimental and Numerical Analysis for Effects of Two Inclined Baffles on Heat Transfer Augmentation in a Rectangular Duct (사각 덕트 내에 설치된 2개의 경사진 배플에 의한 열전달 증진 효과에 관한 실험 수치해석)

  • Kang, Ho-Keun;Ahn, Soo-Whan;Putra, Ary Bachtiar Krishna
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.751-760
    • /
    • 2007
  • Baffles enhance heat transfer by disturbing boundary layer and bulk flow, creating impingement, and increasing heat transfer surface area. This study was performed to determine how the two inclined baffles (${\alpha}=5^{\circ}$ perforated models) placed at a rectangular channel affect heat transfer and associated friction characteristics. The parametric effects of perforated baffles (3, 6 and 12 holes) and flow Reynolds number ranging from 28,900 to 61,800 on the heated target surface are explored. Comparisons of the experimental data with the numerical results by commercial code CFX 10.0 are presented. As for the investigation of heat transfer behaviors on local Nusselt number with two baffles placed at $x/D_h=0.8$ and $x/D_h=8.0$ of the edge of baffles, it is evident that the inclined perforated baffles augment overall heat transfer significantly by both jet impingement and boundary layer separation. There exists an optimum perforation density to maximize heat transfer coefficients; i.e., the average Nusselt number increases with increasing number of holes, but the friction factor decreases with an increase in the hole number placed at baffles.

Acquired Dermoid Cysts within Subcutaneous Scar Tissue (피하 흉터 조직에서 발견된 후천성 유피낭종)

  • Kim, Hyoung Jin;Burm, Jin Sik;Pyon, Jai Kyong;Kim, Yang Woo
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.508-511
    • /
    • 2007
  • Purpose: Dermoid cysts are almost always caused by congenital events. The most widely accepted pathogenesis is that the cysts are dysembryogenetic lesions that arise from ectodermic elements entrapped during the midline fusion. We report a rare case of dermoid cyst, which occurred not congenitally but newly in the subcutaneous scar tissue secondary to trauma. Methods: A 26-year-old man had a deep submental laceration caused by a car accident and got a primary wound closure 16 months ago. There were 18 cm-long submental hypertrophic scar and newly developed palpable masses inside the subcutaneous layer at the center of the scar. Initial impression was an epidermal cyst or a thyroglossal duct cyst. Ultrasonographic finding showed two cystic masses inside the scars at the submental area, but impressed dermoid cysts. The cystic masses were completely removed with W-plasty and histological examination were followed. Results: The histological diagnosis was dermoid cysts which were mainly composed of keratotic squamous epithelium in their inner surface linings and numerous skin appendages such as sebaceous glands, sweat glands, and hair follicles in their cystic lumens histopathologically. During the follow-up period of 25 months, there was no recurrence of any subcutaneous mass in the site of scar. Conclusion: We report a very unusual case of dermoid cysts developed by an acquired cause, considering that the accidental inclusion of deep skin elements caused by a trauma can be a critical origin of dermoid cysts.

Medial Canthopexy using Modified Hiraga's Incision for Correction of Traumatic Telecanthus (외상성 내안각격리증 환자에 있어 Hiraga 절개법을 이용한 내안각 고정술)

  • Lim, Jong-Hyo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Jun-Ho
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.504-508
    • /
    • 2010
  • Purpose: Traumatic telecanthus can result from nasoethmoid-orbital fractures. Repair of the medial canthal tendon (MCT) using transnasal wiring is regarded as a choice of method to treat telecanthus, however, is often complicated by incomplete anchoring and drift of canthus, extrusion of wire, in-fracture of orbital bone, and eye damage. The authors introduced oblique transnasal wiring method through the Hiraga's epicanthopalsty incision instead of well-known classical bicoronal approach. Methods: Five patients with traumatic telecanthus were treated with this method. Though the Hiraga's epicanthoplasty incision, we could approach the operative field; the medial orbital wall and detached MCT. Oblique transnasal wiring was performed as following steps. After slit skin incision on the contralateral nasal recession area, drill holes were made from this point to the superior and posterior point of lacrimal sac of deformed eye. A 2-0 wire was double-passed through the holes and MCT. Traction was applied to ensure pulling the MCT and the wires were twisted in the contralateral nose, securing the MCT in the correct position. Results: All patients except 1 person showed improvement and rapid recovery. On average each canthus was moved 5.6 mm medially. In all cases, there were no eyelashes disappear, lacrimal canaliculitis, lacrimal duct injury, or infections. Conclusion: The Hiraga's epicanthoplasty incision could give sufficient operative field to reattach the MCT in traumatic telecanthus patients. And the oblique transnasal wiring technique is effective for the Asians who have flat nose and exophthalmic eye. The authors conclude that this technique could be a simple, safe and scarless method to correct traumatic telecanthus.

Basic Study on the Performance of a Pressure-difference Control Damper Affected by Flow Disturbance in a Wind Tunnel (풍도 내 유동 교란과 자동차압 댐퍼의 성능 특성 기초 연구)

  • Yun, Yung-Min;Lee, Min-Jung;Kim, Nam-Il;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.16-23
    • /
    • 2009
  • The performance characteristics of a smoke damper, which aims to suppress the penetration of smoke to a safe area, have been tested under the regulation of the FIS 001. However, the improvement of the test methods and the regulation has consecutively been requested. From a view-point of fluid mechanical theory, a pressure control damper, that is installed at the end of the flow control system, is important and it dominates flow characteristics in all designed flow systems. In this study, the weak points of the regulation of the FIS 001 concerned with the pressure control damper was visited and the some important characteristics of the damper was examined. Based on these results, it was confirmed that the effects of flow disturbance in the air supplying duct on the performance of the damper are not significant. This results gives some information for the modification of the experimental regulation concerned to the pressure control damper.