• Title/Summary/Keyword: Duck Bone

Search Result 60, Processing Time 0.027 seconds

Low Grade Osteosarcoma in Proximal Phalanx of the Second Toe - A Case Report- (제 2족지 근위 지골에 발생한 저악성도 골육종 - 증례 보고 -)

  • Han, Chung-Soo;Chung, Duck-Hwan;Shin, Dong-Jun;Lim, Yang-Sun;Jung, Chan-Jong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.151-156
    • /
    • 2001
  • The reported incidence of osteosarcoma of the foot varies between 0.2-2% of all osteosarcoma. Low grade osteosarcoma of the long bone represents only 1.9% of all osteosarcoma. A 38-year-old female had suffered painful mass in the proximal phalanx of the second toe for 1 year. Radiographic finding showed enlarged osteloytic mass which had penetrated thin cortex of the second toe and apparent increased uptake in bone scan was seen. Mass resection with autogenous bone graft using rib was performed. Histologically, the tumor was compatible with "low grade osteosarcoma". Second stage wide resection was performed. Because low grade osteosarcoma located in the proximal phalanx of the second toe is very rare, we report this unusual case with review of literature.

  • PDF

The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study (인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구)

  • Cho, Il-Sik;Choo, Hye-Ran;Kim, Seong-Kyun;Shin, Yun-Seob;Kim, Duck-Su;Kim, Seong-Hun;Chung, Kyu-Rhim;Huang, John C.
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

Microstructure and Mechanical Properties of Nano-sized Ti-35%Nb-7%Zr-10%CPP Composite Fabricated by Pulse Current Activated Sintering (통전가압활성소결을 이용한 나노 결정립 Ti-35%Nb-7%Zr-10%CPP 복합재료의 미세조직 및 기계적 특성)

  • Woo, Kee-Do;Kang, Duck-Soo;Kim, Sang-Hyuk;Park, Sang-Hoon;Kim, Ji-Young;Ko, Hye-Rim
    • Journal of Powder Materials
    • /
    • v.18 no.2
    • /
    • pp.188-195
    • /
    • 2011
  • The aim of this study was to investigate microstructures and mechanical properties of nano-sized Ti-35 wt.%Nb-7 wt.%Zr-10 wt.%CPP composite fabricated by high energy mechanical milling (HEMM) and pulse current activated sintering (PCAS). Grain growth of the mechanically milled powder was prevented by performing PCAS. The principal advantages of calcium phosphate materials include: similarity in composition to the bone mineral, bioactivity, osteoconductivity and ability to form a uniquely strong interface with bone. The hardness and wear resistance property of nano-sized Ti-35 wt.%Nb-7 wt.%Zr-10 wt.%CPP composites increased with increasing milling time because of decreased grain-size of sintered composites.

Evaluation of Surface Macrostructure and Mechanical Properties of Porous Surface Ti-HA Biomaterial Fabricated by a Leaching Process (Leaching 공정으로 제조한 표면 다 기공 Ti-HA 생체재료의 표면 조직 및 기계적 성질의 평가)

  • Woo, Kee Do;Kang, Duck Soo;Moon, Min Seok;Kim, Sang Hyuk;Liu, Zhiguang;Omran, Abdel-Nasser
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.369-375
    • /
    • 2010
  • Ti-6Al-4V ELI alloy, which is commonly used as a biomaterial, is associated with a high elastic modulus and poor biocompatibility. This alloy presents a variety of problems on several areas. Therefore, the development of good non-toxic biocompatible biomaterials with a low elastic modulus is necessary. Particularly, hydroxyapatite (HA) is an attractive material for human tissue implantation. This material is widely used as artificial bone due to its good biocompatibility and similar composition to human bone. Many scientists have studied the fabrication of HA as a biomaterial. However, applications of bulk HA compact are hindered by the low strength of HA when it is sintered. Therefore, HA has been coated on Ti or Ti alloy to facilitate good bonding between tissue and the HA surface. However, there are many problems when doing this, such as the low bonding strength between HA and Ti due to the different thermal expansion coefficients and mechanical properties. In this study, a Ti-HA composite with a porous surface was successfully fabricated by pulse current activated sintering (PCAS) and a subsequent leaching process.

The Effects of the Mixture of Fetal Bovine Serum and Poly-glycolic acid in Rabbit Calvarial Model (Poly-glycolic Acid(PGA)와 우태아 혈청(Fetal bovine serum, FBS)의 혼합물이 가토에서 골형성에 미치는 영향)

  • Sung, Yong Duck;Kim, Yong Ha;Moon, Young Mi;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.298-304
    • /
    • 2007
  • Purpose: This study was undertaken to investigate the osteogenic induction potential of PGA & FBS mixture on a calvarial defect in the rabbit. Methods: Twenty New zealand white rabbit, weighing from 3.5-4kg were allocated into each of the three groups. Four 8 mm sized bone defects were made on the parietal bone by drilling. In group I, the bony defects were implanted with $50{\mu}m$ thickness film containing mixture of PGA and FBS. In group II, with PGA only film, & in group III, the bony defects were left with no implants. Results were evaluated by using morphologic change, radiographic study, biochemical study and histologic examination at 1 week (group I n=7, group II n=7, group III n=14), 2 weeks (group I n=6, group II n=6, group III n=12) and 3 weeks (group I n=7, group II n=7, group III n=14) following implantation. Results: In the morphologic & radiographic study, the formation and corticalization of callus were observed earlier in group I than in groups II and III (p < 0.05). In histological examination, group I showed more abundant and faster new bone formation than in group II and III. In biochemical analysis, group I displayed more activity than in group II and III. Group I also showed more abundant osteopontin, osteocalcin than groups II and III. Conclusion: In conclusion, the results demonstrate that the mixture of PGA and FBS has an effect on osteoblastic formation in the rabbit model. It is considered that further evaluation of long term results on resorption, immunologic tissue reaction and response of applied mixture in the human model will be needed.

The Effect of Adjusted Water Fluoridation on Bone Mineral Density (수돗물불소농도조정사업이 지역주민의 골밀도에 미치는 영향)

  • Han, Yoon-Jung;Min, Jin-Young;Han, Dong-Hun;Kim, Hyun-Duck;Paek, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.261-270
    • /
    • 2008
  • Adjusted water fluoridation has been disputed because of its various effects on human health. Previous studies have been concerned with the difference in bone mineral density (BMD) between water fluoridated (WF) and none water fluoridated (NWF) districts. The aim of this study is to examine whether water fluoridation affects BMD. BMD was measured by dual energy X-ray absorptiometry (DXA). 386 adults(174 males and 212 females) in Ansan (WF) district and 399 adults (176 males and 223 females) in Sihwa (NWF) district, participated in this study. The Ansan and Sihwa districts are similar in residential environment and living class. The relationship between serum fluoride concentration and BMD was also examined by analysis of the serum fluoride concentrations from 402 inhabitants of the Ansan district. In females, the BMD of subjects living in Ansan ($0.457{\pm}0.008$) was a little higher than that of Sihwa subjects ($0.446{\pm}0.008$), although it is not significant, after adjusting for BMI, physical activity level, educational achievement, smoking volume, menopause status, and number of births. However, the BMD of Ansan subjects ($0.532{\pm}0.020$) in their forties was statistically higher than that of Sihwa (0.498{\pm}0.019). No relationship was found in males. In residential periods, there was significant difference (Ansan $0.467{\pm}0.013$, Sihwa $0.434{\pm}0.012$, p=0.0125) in the BMD between females of two districts, particularly in the group of over 6 year long-term inhabitants. On the contrary, there was no remarkable difference in males from the two districts. Serum fluoride concentrations in females were associated with BMD, especially in the age group of forties (p=0.0457). No relationship was observed in the male group. Analysis of adult BMD over the age of 20 in a water fluoridated and a none water fluoridated district, confirms more or less a higher BMD in the water fluoridated (WF) district, especially for females. It is assumed that the difference between two districts came somewhat from the effect of water fluoridation.

Biologic response of local hemostatic agents used in endodontic microsurgery

  • Jang, Youngjune;Kim, Hyeon;Roh, Byoung-Duck;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • Appropriate use of local hemostatic agent is one of the important factors on the prognosis of endodontic microsurgery. However, most investigations to date focus on the hemostatic efficacy of the agents, whereas their biologic characteristics have not received enough attention. The purpose of this paper was to review the biologic response of local hemostatic agents, and to provide clinical guidelines on their use during endodontic microsurgery. Electronic database (PUBMED) was screened to search related studies from 1980 to 2013, and 8 clinical studies and 18 animal studies were identified. Among the materials used in these studies, most widely-investigated and used materials, epinephrine, ferric sulfate (FS) and calcium sulfate (CS), were thoroughly discussed. Influence of these materials on local tissue and systemic condition, such as inflammatory and foreign body reaction, local ischemia, dyspigmentation, delayed or enhanced bone and soft tissue healing, and potential cardiovascular complications were assessed. Additionally, biological property of their carrier materials, cotton pellet and absorbable collagen, were also discussed. Clinicians should be aware of the biologic properties of local hemostatic agents and their carrier materials, and should pay attention to the potential complications when using them in endodontic microsurgery.

Accidental injury of the inferior alveolar nerve due to the extrusion of calcium hydroxide in endodontic treatment: a case report

  • Shin, Yooseok;Roh, Byoung-Duck;Kim, Yemi;Kim, Taehyeon;Kim, Hyungjun
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.63-67
    • /
    • 2016
  • During clinical endodontic treatment, we often find radiopaque filling material beyond the root apex. Accidental extrusion of calcium hydroxide could cause the injury of inferior alveolar nerve, such as paresthesia or continuous inflammatory response. This case report presents the extrusion of calcium hydroxide and treatment procedures including surgical intervention. A 48 yr old female patient experienced Calcipex II extrusion in to the inferior alveolar canal on left mandibular area during endodontic treatment. After completion of endodontic treatment on left mandibular first molar, surgical intervention was planned under general anesthesia. After cortical bone osteotomy and debridement, neuroma resection and neurorrhaphy was performed, and prognosis was observed. But no improvement in sensory nerve was seen following surgical intervention after 20 mon. A clinician should be aware of extrusion of intracanal medicaments and the possibility of damage on inferior alveolar canal. Injectable type of calcium hydroxide should be applied with care for preventing nerve injury. The alternative delivery method such as lentulo spiral was suggested on the posterior mandibular molar.

COMPLICATIONS ASSOCIATED WITH DENTAL IMPLANT SURGERY; CASE REPORT (임플란트 수술 시의 합병증; 증례 보고)

  • Lee, Hyun-Jin;Yeo, Duck-Sung;Lim, So-Yeon;An, Kyung-Mi;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • According to the increase in use of implants in clinical dentistry, new kinds of complications happen. Complications that can happen during implant placement are bleeding, nerve injury, jaw fracture, fenestration of maxillary sinus or nasal cavity, dehiscence, fenestration, injury of adjacent tooth. And complications that can happen after implant operation are infection, bleeding, hematoma, chronic sinusitis, peri-implantitis. Problems that are confronted during implant placement happen by inadequate preoperative treatment plan, inadequate consideration about individual anatomic difference, inadequate operation process and lack of experience of clinician. It is important that clinicians consider possible complications in advance and make a comprehensive treatment plan. We report the patient who was happened ramus fracture during block bone harvesting from ramus of severely atrophic mandible, the patient who came to emergency ward due to postoperative swelling and bleeding and the patient whose implant was migrated to maxillary sinus with a review of literature.

Tumoral calcinosis of the prepatellar bursa -a case report- (슬개골전 점액낭에 발생한 Tumoral Calcinosis - 증례보고 -)

  • Kim, Hee-Chun;Song, Kwang-Jin;Cho, Duck-Yun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.2
    • /
    • pp.127-130
    • /
    • 1997
  • Tumoral calcinosis is a rare disorder of unknown etiology, which is characterized by the developement of large calcified masses overlying the large joints in otherwise healthy subjects. If histologic tests are not confirmed, the condition may be treated erroneously as bursitis. This report describes the case of a 10-year-old man with tumoral calcinosis of the knee, a joint very rarely affected by this unusual disorder. Microscopically the tumor consists of a stroma of chronic inflammatory tissue surrounding cystic spaces containing calcium-rich material. We made excision alone, and the patient made an uneventful recovery with no evidence of recurrence up to 13 months postoperatively.

  • PDF