• Title/Summary/Keyword: Dual-beam

Search Result 285, Processing Time 0.034 seconds

Practical Design Method for Coupling Beams of Tall Buildings with Dual Frame System (이중골조형식 고층건물 커플링보의 실용설계)

  • Yoon, Tae-Ho;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.525-532
    • /
    • 2014
  • In this study, practical design method of coupling beams is proposed. The member forces varies according to the location of the members and the members at 25%~40% of building height shows large member forces. The 100mm increase of wall thickness causes 3~4% variation of member forces and the 100MPa increase of concrete strength decrease approximately 3% of member forces. The required strength of coupling beams is twice the resistant strength and 80% reduction of coupling beam stiffness is necessary to fulfill the design criteria. The stiffness reduction of coupling beams is not necessary over the entire stories and the strength reduction range can be estimated considering design requirements.

Analysis of extended end plate connection equipped with SMA bolts using component method

  • Toghroli, Ali;Nasirianfar, Mohammad Sadegh;Shariati, Ali;Khorami, Majid;Paknahad, Masoud;Ahmadi, Masoud;Gharehaghaj, Behnam;Zandi, Yousef
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.213-228
    • /
    • 2020
  • Shape Memory Alloys (SMAs) are new materials used in various fields of science and engineering, one of which is civil engineering. Owing to their distinguished capabilities such as super elasticity, energy dissipation, and tolerating cyclic deformations, these materials have been of interest to engineers. On the other hand, the connections of a steel structure are of paramount importance because of their vulnerabilities during an earthquake. Therefore, it is indispensable to find approaches to augment the efficiency and safety of the connection. This research investigates the behavior of steel connections with extended end plates equipped hybridly with 8 rows of high strength bolts as well as Nitinol superelastic SMA bolts. The connections are studied using component method in dual form. In this method, the components affecting the connections behavior, such as beam flange, beam web, column web, extended end plate, and bolts are considered as parallel and series springs according to the Euro-Code3. Then, the nonlinear force- displacement response of the connection is presented in the form of moment-rotation curve. The results obtained from this survey demonstrate that the connection has ductility, in addition to its high strength, due to high ductility of SMA bolts.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

PBMS (Particle Beam Mass Spectrometer)를 이용한 실리콘 나노입자 합성 특성의 실시간 분석에 관한 연구

  • Choe, Hu-Mi;Kim, Dong-Bin;An, Chi-Seong;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.233-233
    • /
    • 2012
  • 나노입자가 가지는 고유한 특성이 부각되면서 이를 소자 특성 향상에 응용하고자 하는 연구가 집중적으로 이루어지고 있다. 박막에 포함된 나노입자는 메모리, 고효율 박막형 태양전지 등에 이용될 수 있는 가능성을 보여주었으며, 나노입자에 기반 하는 소자 제조에 관한 연구가 이루어지면서 플라즈마 내 발생하는 나노입자를 이용하여 패터닝 등에 적용하고자 하는 연구가 국내외에서 활발히 이루어지고 있다. 특히 플라즈마에서 발생하는 나노입자는 플라즈마 내 전기적 및 화학적 특징으로 인해 다른 입자 제조 공정과 달리 응집이 없는 균일한 입자를 제조할 수 있다. 이러한 플라즈마 내 발생 입자를 응용하기 위해서는 각각의 응용 분야에 적합한 입경 분포 제어가 요구된다. 하지만 입자 합성 시 크기분포 특성에 관한 연구는 기존의 포집 및 전자현미경을 이용한 방법으로 실시간으로 분석하기에는 한계가 있다. 따라서 본 연구에서는 저압에서 실시간으로 나노입자 분포를 측정할 수 있는 PBMS (particle beam mass spectrometer)를 이용하여, PECVD (plasma enhanced chemical vapor deposition)의 입자 생성 조건에 따라 continuous, pulse, dual pulse로 분류되는 공정 조건에서 생성되는 입자의 크기 분포를 측정하였다. 또한 그 결과를 기존의 동일한 조건에서 포집 후 SMPS (scanning mobility particle sizer)와 전자 현미경을 이용하여 분석한 결과와 비교하였다. 실리콘 나노 입자의 측정은 PBMS 장비의 전단 부분을 PECVD 장치 내부에 연결하여 진행하였다. PECVD를 이용한 실리콘 나노입자 형성의 주요 변수는 RF pulse, 가스(Ar, SiH4, H2)의 유량, Plasma power, 공정 압력 등이 있으며 각 변수를 조절하여 공정 환경을 구성하였다. 결론적으로 본 연구를 통하여 PECVD를 이용해 각각의 공정 환경에서 생성되는 실리콘 나노입자의 실시간 입경 분포 분석을 PBMS로 수행하는 것에 신뢰성이 있음을 알 수 있었으며, 그 경향을 확인할 수 있었다. 추후 지속적 연구에 의해 변수에 따른 나노입자 생성을 데이터베이스화 하여 요구되는 응용분야에 적합한 특성을 가지는 나노입자를 형성하는 조건을 정립 하는데 중요한 역할을 할 것을 기대할 수 있다.

  • PDF

Simultaneous Measurement of Strain and Damage Signal of Composite Structures Using a Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 복합재 구조물의 변형률 및 파손신호 동시 측정)

  • Koh Jong-In;Bang Hyung-Joon;Kim Chun-Gon;Hong Chang-Sun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.95-102
    • /
    • 2004
  • For the simultaneous measurement of strain and damage signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter can measure low-frequency signal such as strain and the other demodulator using a passive Mach-Zehnder interferometer can detect high-frequency signal such as damage signal or impact signal. Using a proposed fiber Bragg grating sensor system, both the strain and damage signal of a cross-ply laminated composite beam under tensile loading were simultaneously measured. Analysis of the strain and damage signals detected by single fiber Bragg grating sensor showed that sudden strain shifts were induced due to transverse crack propagation in the 90 degree layer of composite beam and vibration with a maximum frequency of several hundreds of kilohertz was generated.

  • PDF

Polydopamine Coating Behaviors on the Acrylic Acid Grafted-Nanofibers (아크릴산이 그라프트된 나노섬유에서의 폴리도파민 코팅)

  • Shin, Young Min;Kim, Woo-Jin;Park, Jong-Seok;Gwon, Hui-Jeong;Nho, Young-Chang;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.371-376
    • /
    • 2011
  • The surface property of the materials used in tissue engineering application has been essential to regulate cellular behaviors by directing their adhesion on the materials. To modulate surface property of the synthetic biodegradable materials, a variety of surface modification techniques have used to introduced surface functional groups or bioactive molecules, recently polydopamine coating method have been introduce as a facile modification method which can be coated on various materials such as polymers, metals, and ceramics regardless of their surface property. However, there are no reports about the degree of polydopamine coating on the materials with different hydrophilicity. In the present study, we prepared acrylic acid grafted nanofibrous meshes using electron-beam irradiation, and then coated meshes with polydopamine. Polydopamine successfully coated on the all meshes, both properties of acrylic acid and polydopamine were detected on the meshes. In addition, the degree of polydopamine deposition on the materials has been altered according to surface hydrophilicity, which was approximately 8-times greater than those on the non-modified materials. In conclusion, dual effect from the acrylic acid grafting and polydopamine may give a chance as a alternative tool in tissue engineering application.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Development of Single Feed Antenna for Integrated Public Network and 5G Network Frequency Dual-band Cover (통합 공공망과 5G 주파수 이중대역 커버용 단일 급전 안테나 개발)

  • Hong, Ji-Hun;Choi, Yoon-Seon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.233-240
    • /
    • 2019
  • In this paper, due to the development of 5G communication technology, an antenna capable of covering both LTE and 5G bands is currently needed. In addition, we designed and manufactured a single feed antenna for the integrated public network (LTE) and 5G frequency dual band cover to satisfy the frequency bandwidth of more than 10% in each band. The antenna designed by adopting the dipole of the basic dipole antenna in a planar structure is a form in which the radiating element is vertically extended at all of the 700 MHz antennas and folded into a 'ㄷ' shape. In addition, the radiating element of the 700MHz band serves as a reflector of the 3.5GHz band radiating element. As a result, the 700 MHz band -10 dB bandwidth 104 MHz(14.8%) and 3.5 GHz band -10 dB bandwidth 660 MHz(18.8%) were obtained and the radiation pattern characteristic resulted in gains of 8.46 dBi, beam width E-plane 55°, H-plane 81° and 3.5 GHz bands 6.14 dBi, beamwidth E-plane 79°, H-Plane 49°.

Kernel Integration Scheme for 2D Linear Elastic Direct Boundary Element Method Using the Subparametric Element (저매개변수 요소를 사용한 2차원 선형탄성 직접 경계요소법의 Kernel 적분법)

  • Jo, Jun-Hyung;Park, Yeongmog;Woo, Kwang-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.413-420
    • /
    • 2012
  • In this study, the Kernel integration scheme for 2D linear elastic direct boundary element method has been discussed on the basis of subparametric element. Usually, the isoparametric based boundary element uses same polynomial order in the both basis function and mapping function. On the other hand, the order of mapping function is lower than the order of basis function to define displacement field when the subparametric concept is used. While the logarithmic numerical integration is generally used to calculate Kernel integration as well as Cauchy principal value approach, new formulation has been derived to improve the accuracy of numerical solution by algebraic modification. The subparametric based direct boundary element has been applied to 2D elliptical partial differential equation, especially for plane stress/strain problems, to demonstrate whether the proposed algebraic expression for integration of singular Kernel function is robust and accurate. The problems including cantilever beam and square plate with a cutout have been tested since those are typical examples of simple connected and multi connected region cases. It is noted that the number of DOFs has been drastically reduced to keep same degree of accuracy in comparison with the conventional isoparametric based BEM. It is expected that the subparametric based BEM associated with singular Kernel function integration scheme may be extended to not only subparametric high order boundary element but also subparametric high order dual boundary element.

A Study on SS400 Cutting Characteristics using Continuous Wave Fiber Laser (연속파 파이버 레이저를 이용한 SS400의 절단 특성에 관한 연구)

  • Oh, Yong-Seok;Lee, Ka-Ram;Park, Eun-Kyeong;Yoo, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.644-650
    • /
    • 2012
  • This paper show the 2kW fiber laser cutting properties of SS400. The study was comparison of traditional 4kW $CO_2$ Laser cutting and 2kW Fiber laser cutting characteristics for the application of Industrial 2D Laser Cutting Machine. The laser used in this investigation was an IPG YLU-2000 multi-mode Ytterbium Fiber machine with a maximum power of 2000W and a wave length of 1070 nm. The laser was used in its Continuous Wave (CW) mode with an approximately top hat beam intensity distribution. Fiber laser high quality cuts at a large range of speeds (ranging from 2000 to 3800 mm/min) which has been obtained for the 2.3mm Sheet of SS400. 2kW power Fiber laser cut was able to max. 20mm sheets of SS400 (speed range from 650 to 850 mm/min). Fiber laser cutting used in conventional hole nozzle could cut 12mm SS400 but used in special dual cutting nozzle could cut 20mm SS400.